期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
蓄能器的蓄能性能研究 被引量:14
1
作者 范基 吴劲 《液压工业》 1990年第2期2-6,共5页
蓄能器在液压系统中用于均衡系统的流量,稳定系统的压力或回收系统的能量。由于使用目的不同,对其性能要求也不同,如车辆用的油气悬挂蓄能器,重点是固有频率及刚度特性;用作均衡系统流量的蓄能器,侧重于可供实际使用的有效容积;用作储... 蓄能器在液压系统中用于均衡系统的流量,稳定系统的压力或回收系统的能量。由于使用目的不同,对其性能要求也不同,如车辆用的油气悬挂蓄能器,重点是固有频率及刚度特性;用作均衡系统流量的蓄能器,侧重于可供实际使用的有效容积;用作储存能量的储能器,研究蓄能器工作循环过程中的能量损失。本文就对4升和25升蓄能器在蓄能和释放过程的机理及影响效率的因素进行了研究。 展开更多
关键词 蓄能 液压系统 蓄能性能
下载PDF
Characteristic and optimization of ferrite-rich sulfoaluminate-based composite cement suitable for cold region tunnels
2
作者 PENG You LI Li +5 位作者 TAN Xian-jun QIU Xin ZHENG Pei-chao XIE Jun CHEN Wei-zhong REZIWANGULI Sha-ta-er 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第8期2794-2809,共16页
To develop suitable grouting materials for water conveyance tunnels in cold regions,firstly,this study investigated the performance evolution of ferrite-rich sulfoaluminate-based composite cement(FSAC grouting materia... To develop suitable grouting materials for water conveyance tunnels in cold regions,firstly,this study investigated the performance evolution of ferrite-rich sulfoaluminate-based composite cement(FSAC grouting material)at 20 and 3℃.The results show that low temperature only delays the strength development of FSAC grouting material within the first 3 d.Then,the effect of four typical early strength synergists on the early properties of FSAC grouting material was evaluated to optimize the early(£1 d)strength at 3℃.The most effective synergist,Ca(HCOO)_(2),which enhances the low-temperature early strength without compromising fluidity was selected based on strength and fluidity tests.Its micro-mechanism was analyzed by XRD,TG,and SEM methods.The results reveal that the most suitable dosage range is 0.3 wt%−0.5 wt%.Proper addition of Ca(HCOO)_(2)changed the crystal morphology of the hydration products,decreased the pore size and formed more compact hydration products by interlocking and overlapping.However,excessive addition of Ca(HCOO)_(2)inhibited the hydration reaction,resulting in a simple and loose structure of the hydration products.The research results have reference value for controlling surrounding rock deformation and preventing water and mud inrushes during the excavation in cold region tunnels. 展开更多
关键词 ferrite-rich sulfoaluminate cement cold zone early strength synergist mechanical property MICRO-STRUCTURE pumped storage power
下载PDF
三套管相变蓄能换热器蓄释能性能实验研究 被引量:2
3
作者 杨灵艳 周权 +1 位作者 倪龙 姚杨 《煤气与热力》 2012年第5期18-21,共4页
介绍了三套管相变蓄能换热器结构,建立了实验台,对其蓄释能性能进行了研究。对实验结果进行回归拟合,拟合结果与实验值的相对误差在可接受范围。三套管相变蓄能换热器可实现有效的换热,蓄释能性能优良。
关键词 三套管相变蓄能换热器 相变材料 能性能
下载PDF
新产品新技术
4
《墙材革新与建筑节能》 2005年第11期55-58,共4页
关键词 聚四氟乙烯玻纤 建筑膜材 蓄能性能 墙体材料 保温涂料 加气混凝土
下载PDF
Energy Performance Analysis of Ice Thermal Storage for Commercial HVAC Systems 被引量:1
5
作者 Nabil Nassif Raymond Tesiero Nihal AI Raees 《Journal of Energy and Power Engineering》 2013年第9期1713-1718,共6页
Ice thermal storage is a promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper investigates the application of ice thermal storage and its impact on energ... Ice thermal storage is a promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper investigates the application of ice thermal storage and its impact on energy consumption, demand and total energy cost. Energy simulation software along with a chiller model is used to simulate the energy consumption and demand for the existing office building located in central Florida. Furthermore, the study presents a case study to demonstrate the cost saving achieved by the ice storage applications. The results show that although the energy consumption may increase by using ice thermal storage, the energy cost drops significantly, mainly depending on the local utility rate structure. It found that for the investigated system the annual energy consumption increases by about 12% but the annual energy cost drops by about 3 6%. 展开更多
关键词 HVAC system ice thermal storage central plant chiller.
下载PDF
Direction Dependence of Savings on Cooling and Heating Loads by Energy Efficient Windows
6
作者 Kazuki Yoshimura 《Journal of Energy and Power Engineering》 2014年第12期2012-2016,共5页
The energy saving performance of energy efficient windows has strong dependence on window direction. Transmitted insolation level definitely affected the cooling and heating load. Simple simulation on the decrement of... The energy saving performance of energy efficient windows has strong dependence on window direction. Transmitted insolation level definitely affected the cooling and heating load. Simple simulation on the decrement of cooling load and the increment of heating load of a shading window compared with those of a transparent window show the prospect of energy saving effect clearly.From southeastward to southwestward, shading window even enlarges total heating and cooling loads when the thermal transmission is the same. However, if the shading coefficient of window is switched between summer and winter, total cooling and heating load can be reduced. This result clarifies the importance of "smart window". 展开更多
关键词 Cooling load heating load shading coefficient U-vaLue.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部