The interface of slab track laid in cold regions is prone to debonding under the coupling of freeze-thaw cyclesand temperature loads.Based on the composite specimen tests,the parameters of cohesive zone model were obt...The interface of slab track laid in cold regions is prone to debonding under the coupling of freeze-thaw cyclesand temperature loads.Based on the composite specimen tests,the parameters of cohesive zone model were obtained andused in a simulation model of CRTS III prefabricated slab track to study the interlayer damage.The results show that 1)the digital image correlation(DIC)technique can accurately capture the strain field changes on the interface of compositespecimens under splitting and shear loading;2)when the temperature gradient is−40℃/m−60℃/m,the interfacedamage of the slab track is minimal and presents different patterns of expansion under positive and negative temperaturegradients,each corresponding to damage of the cohesive element dominated by shear stress and normal tensile stress,respectively;3)the reduction of the elastic modulus at the concrete base after freeze-thaw inhibits interface damage andleads to a higher starting temperature gradient load,but cracking can occur on the concrete base after 150 freeze-thaws.For this reason,in the light of damage control of both the interface and concrete base,the elastic modulus of the concretebase is 54%or over that without freeze-thaw cycles.展开更多
This paper studied an integrative fault diagnostic system on the power transformer. On-line monitor items were grounded current of iron core, internal partial discharge and oil dissolved gas. Diagnostic techniques wer...This paper studied an integrative fault diagnostic system on the power transformer. On-line monitor items were grounded current of iron core, internal partial discharge and oil dissolved gas. Diagnostic techniques were simple rule-based judgment, fuzzy logistic reasoning and neural network distinguishing. Considering that much faults information was interactional, intellectualized diagnosis was implemented based on integrating the neural network with the expert system. Hologamous integrating strategies were materialized by information-based integrating monitor devices, shared information database on several levels and fusion diagnosis software along thought patterns. The expert system practiced logic thought by logistic reasoning. The neural network realized image thought by model matching. Creative conclusion was educed by their integrating. The diagnosis example showed that the integrative diagnostic system was reasonable and practical.展开更多
Aiming at the problems of power structure irrationality, lagging of power network behind power source development and high proportion of overdone and small sized units existing currently in power system in China, fina...Aiming at the problems of power structure irrationality, lagging of power network behind power source development and high proportion of overdone and small sized units existing currently in power system in China, financial and running strategies are set forth corresponding to power system restructuring.展开更多
基金Project(52425213)supported by the National Science Fund for Distinguished Young Scholars of ChinaProjects(52278461,52308467)supported by the National Natural Science Foundation of China+1 种基金Projects(2021YFF0502100,2021YFB2600900)supported by the National Key R&D Program of ChinaProject(2022JDTD0015)supported by the Sichuan Province Youth Science and Technology Innovation Team,China。
文摘The interface of slab track laid in cold regions is prone to debonding under the coupling of freeze-thaw cyclesand temperature loads.Based on the composite specimen tests,the parameters of cohesive zone model were obtained andused in a simulation model of CRTS III prefabricated slab track to study the interlayer damage.The results show that 1)the digital image correlation(DIC)technique can accurately capture the strain field changes on the interface of compositespecimens under splitting and shear loading;2)when the temperature gradient is−40℃/m−60℃/m,the interfacedamage of the slab track is minimal and presents different patterns of expansion under positive and negative temperaturegradients,each corresponding to damage of the cohesive element dominated by shear stress and normal tensile stress,respectively;3)the reduction of the elastic modulus at the concrete base after freeze-thaw inhibits interface damage andleads to a higher starting temperature gradient load,but cracking can occur on the concrete base after 150 freeze-thaws.For this reason,in the light of damage control of both the interface and concrete base,the elastic modulus of the concretebase is 54%or over that without freeze-thaw cycles.
文摘This paper studied an integrative fault diagnostic system on the power transformer. On-line monitor items were grounded current of iron core, internal partial discharge and oil dissolved gas. Diagnostic techniques were simple rule-based judgment, fuzzy logistic reasoning and neural network distinguishing. Considering that much faults information was interactional, intellectualized diagnosis was implemented based on integrating the neural network with the expert system. Hologamous integrating strategies were materialized by information-based integrating monitor devices, shared information database on several levels and fusion diagnosis software along thought patterns. The expert system practiced logic thought by logistic reasoning. The neural network realized image thought by model matching. Creative conclusion was educed by their integrating. The diagnosis example showed that the integrative diagnostic system was reasonable and practical.
文摘Aiming at the problems of power structure irrationality, lagging of power network behind power source development and high proportion of overdone and small sized units existing currently in power system in China, financial and running strategies are set forth corresponding to power system restructuring.