AIM:To evaluate the utility of assessing iodized oil uptake with cone-beam computed tomography(CT)in transarterial chemoembolization(TACE)for small he-patocellular carcinoma(HCC).METHODS:Cone-beam CT provided by a bip...AIM:To evaluate the utility of assessing iodized oil uptake with cone-beam computed tomography(CT)in transarterial chemoembolization(TACE)for small he-patocellular carcinoma(HCC).METHODS:Cone-beam CT provided by a biplane flat-panel detector angiography suite was performed on eighteen patients(sixteen men and two women;41-76 years;mean age,58.9 years)directly after TACE for small HCC(26 nodules under 30 mm;mean diam-eter,11.9 mm;range,5-28 mm).The pre-procedural locations of the tumors were evaluated using tripha-sic multi-detector row helical computed tomography(MDCT).The tumor locations on MDCT and the iodized oil uptake by the tumors were analyzed on cone-beam CT and on spot image directly after the procedures.RESULTS:All lesions on preprocedural MDCT were de-tected using iodized oil uptake in the lesions on cone-beam CT(sensitivity 100%,26/26).Spot image depictediodized oil uptake in 22 of the lesions(sensitivity 85%).The degree of iodized oil uptake was overestimated(9%,2/22)or underestimated(14%,3/22)on spot image in f ive nodules compared with that of cone-beam CT.CONCLUSION:Cone-beam CT is a useful and conve-nient tool for assessing the iodized oil uptake of small hepatic tumors(< 3 cm)directly after TACE.展开更多
Objective To explore the causes, prevention, and management of the complications during intra-cranial aneurysm embolization with controllable coils (mechanical detachable spiral, MDS; and Guglielmi detachable coil, GD...Objective To explore the causes, prevention, and management of the complications during intra-cranial aneurysm embolization with controllable coils (mechanical detachable spiral, MDS; and Guglielmi detachable coil, GDC). Methods Retrospective review of 120 cases with 125 intracranial aneurysms embolized with con-trollable coils from March 1995 to July 1999 was conducted. The 20 accidents(in 18 cases) including aneurysm rupture, over-embolization, protrusion of coil end into the parent artery, and thrombosis of the parent artery were analyzed. Results Among the 20 accidents, there were 6 aneurysm ruptures, 6 over-embolizations (in 5 cases), 6 coil protrusions, and 2 thromboses (one was secondary to coil protrusion). The embolization-related mortality was 3.33% (4/120), the permanent neurological deficit was 1.67% (2/120), and the transitory neurological deficit was 3.33%(4/120). The occurrence and outcome of the complications were related to the embolizing technique, the pattern of aneurysm and its parent artery, the imperfection of embolic materials, and the observation and management during embolization. Conclusion Skilled embolizing technique, better understanding of the angio-anatomy of an aneurysm and its parent artery, correct judgement and management during embolization, and improvement of embolic materials are beneficial to the reduction of complications and to the melioration of the outcome of complications.展开更多
基金Supported by A Grant of the Korea Healthcare technology R&D Project,Ministry for Health,Welfare & Family Affairs,Republic of Korea,A091047
文摘AIM:To evaluate the utility of assessing iodized oil uptake with cone-beam computed tomography(CT)in transarterial chemoembolization(TACE)for small he-patocellular carcinoma(HCC).METHODS:Cone-beam CT provided by a biplane flat-panel detector angiography suite was performed on eighteen patients(sixteen men and two women;41-76 years;mean age,58.9 years)directly after TACE for small HCC(26 nodules under 30 mm;mean diam-eter,11.9 mm;range,5-28 mm).The pre-procedural locations of the tumors were evaluated using tripha-sic multi-detector row helical computed tomography(MDCT).The tumor locations on MDCT and the iodized oil uptake by the tumors were analyzed on cone-beam CT and on spot image directly after the procedures.RESULTS:All lesions on preprocedural MDCT were de-tected using iodized oil uptake in the lesions on cone-beam CT(sensitivity 100%,26/26).Spot image depictediodized oil uptake in 22 of the lesions(sensitivity 85%).The degree of iodized oil uptake was overestimated(9%,2/22)or underestimated(14%,3/22)on spot image in f ive nodules compared with that of cone-beam CT.CONCLUSION:Cone-beam CT is a useful and conve-nient tool for assessing the iodized oil uptake of small hepatic tumors(< 3 cm)directly after TACE.
文摘Objective To explore the causes, prevention, and management of the complications during intra-cranial aneurysm embolization with controllable coils (mechanical detachable spiral, MDS; and Guglielmi detachable coil, GDC). Methods Retrospective review of 120 cases with 125 intracranial aneurysms embolized with con-trollable coils from March 1995 to July 1999 was conducted. The 20 accidents(in 18 cases) including aneurysm rupture, over-embolization, protrusion of coil end into the parent artery, and thrombosis of the parent artery were analyzed. Results Among the 20 accidents, there were 6 aneurysm ruptures, 6 over-embolizations (in 5 cases), 6 coil protrusions, and 2 thromboses (one was secondary to coil protrusion). The embolization-related mortality was 3.33% (4/120), the permanent neurological deficit was 1.67% (2/120), and the transitory neurological deficit was 3.33%(4/120). The occurrence and outcome of the complications were related to the embolizing technique, the pattern of aneurysm and its parent artery, the imperfection of embolic materials, and the observation and management during embolization. Conclusion Skilled embolizing technique, better understanding of the angio-anatomy of an aneurysm and its parent artery, correct judgement and management during embolization, and improvement of embolic materials are beneficial to the reduction of complications and to the melioration of the outcome of complications.