The methods for reducing interface aperture inconsistency are studied in NC orbital milling(NCOM)of CFRP/Ti6Al4V laminates with coarse pitch.Comparative experiments show burr,aperture inconsistency and error are typic...The methods for reducing interface aperture inconsistency are studied in NC orbital milling(NCOM)of CFRP/Ti6Al4V laminates with coarse pitch.Comparative experiments show burr,aperture inconsistency and error are typical interface defects.Meanwhile,aperture inconsistency and error are more serious than burr in NCOM with coarse pitch.As one of the major causes of interface defects,axial force and radial force are intensively studied.Based upon the machining principle of orbital milling(OM)and the actual hole-making condition in laminated structures,NCOM experiments with coarse pitch are conducted on CFRP/Ti6Al4V laminates under different cutting conditions.Then,the effects of interlayer clamping,minimal quantity lubrication(MQL),twice milling instead of reaming,and interlayer speed change on interface aperture are analyzed.Research shows that interlayer clamping,interlayer speed change and MQL can effectively reduce out-of-tolerance of interface aperture.When making holes of different diameters with one cutter,axial feed has a greater effect on interface aperture precision than tangential feed.When making holes of the same diameter with different cutters,small diameter cutter will reduce interface aperture precision in a single processing.But the method of“twice milling instead of reaming”can improve the aperture precision effectively.展开更多
Objective: To get morphologic parameters of Chinese adults through observation and measurement on axial laminas, to evaluate the feasibility of placing axial laminar screws and to introduce the technique. Methods: ...Objective: To get morphologic parameters of Chinese adults through observation and measurement on axial laminas, to evaluate the feasibility of placing axial laminar screws and to introduce the technique. Methods: Relative parameters of 28 sets of fresh Chinese adults' axial specimens, including distance from the superior and inferior entry points of axial laminar screws to the superior margins of axial laminas, superior, middle, inferior thickness and height of the axial laminas, length and angle of the axial laminar screw trajectories, distance from the entry points of axial laminar screws to the transverse foramen and central points of the inferior articular process, were measured with a digital caliper and a goniometer. Data were statistically analyzed. Results: Averagely, distance from the superior and inferior entry points of axial laminar screws to the superior margins of axial laminas was 5 mm and 9 mm, superior, middle, inferior thickness and the height of the axial laminas were 3.2 mm, 6.7 mm, 5.5 mm and 12.8 mm respectively, and the length of the superior and inferior axial laminar screw trajectories was 26.2 mm and 25.5 ram, respectively. Conclusions: It is feasible and reliable to apply posterior laminar screw fixation techniques to the axes of Chinese adults. Also the C2 laminar screw fixation technique can be taken as a supplementary to conventional posterior screw fixations of C2.展开更多
基金Natural Science Research in Jiangsu Province(No.17KJB460008)the 333 Project Research Funding Project in Jiangsu Province(No.BRA2018310)the Innovation Project of Jiangsu Province.
文摘The methods for reducing interface aperture inconsistency are studied in NC orbital milling(NCOM)of CFRP/Ti6Al4V laminates with coarse pitch.Comparative experiments show burr,aperture inconsistency and error are typical interface defects.Meanwhile,aperture inconsistency and error are more serious than burr in NCOM with coarse pitch.As one of the major causes of interface defects,axial force and radial force are intensively studied.Based upon the machining principle of orbital milling(OM)and the actual hole-making condition in laminated structures,NCOM experiments with coarse pitch are conducted on CFRP/Ti6Al4V laminates under different cutting conditions.Then,the effects of interlayer clamping,minimal quantity lubrication(MQL),twice milling instead of reaming,and interlayer speed change on interface aperture are analyzed.Research shows that interlayer clamping,interlayer speed change and MQL can effectively reduce out-of-tolerance of interface aperture.When making holes of different diameters with one cutter,axial feed has a greater effect on interface aperture precision than tangential feed.When making holes of the same diameter with different cutters,small diameter cutter will reduce interface aperture precision in a single processing.But the method of“twice milling instead of reaming”can improve the aperture precision effectively.
文摘Objective: To get morphologic parameters of Chinese adults through observation and measurement on axial laminas, to evaluate the feasibility of placing axial laminar screws and to introduce the technique. Methods: Relative parameters of 28 sets of fresh Chinese adults' axial specimens, including distance from the superior and inferior entry points of axial laminar screws to the superior margins of axial laminas, superior, middle, inferior thickness and height of the axial laminas, length and angle of the axial laminar screw trajectories, distance from the entry points of axial laminar screws to the transverse foramen and central points of the inferior articular process, were measured with a digital caliper and a goniometer. Data were statistically analyzed. Results: Averagely, distance from the superior and inferior entry points of axial laminar screws to the superior margins of axial laminas was 5 mm and 9 mm, superior, middle, inferior thickness and the height of the axial laminas were 3.2 mm, 6.7 mm, 5.5 mm and 12.8 mm respectively, and the length of the superior and inferior axial laminar screw trajectories was 26.2 mm and 25.5 ram, respectively. Conclusions: It is feasible and reliable to apply posterior laminar screw fixation techniques to the axes of Chinese adults. Also the C2 laminar screw fixation technique can be taken as a supplementary to conventional posterior screw fixations of C2.