Objective To analyze the influence of segmental pedicle screws versus hybrid instrumentation on the correction results in adolescent idiopathic scoliosis patients undergoing posterior selective thoracic fusion. Metho...Objective To analyze the influence of segmental pedicle screws versus hybrid instrumentation on the correction results in adolescent idiopathic scoliosis patients undergoing posterior selective thoracic fusion. Methods By reviewing the medical records and roentgenograms of adolescent idiopathic scoliosis patients who underwent selective thoracic fusion from February 2000 to January 2007 in our hospital, the patients were divided into 2 groups according to different instrumentation fashions: Group A was hook-screw-rod (hybrid) internal fixation type, Group B was screw-rod (all pedicle screws) internal fixation type, and the screws were used in every segment on the concave side of the thoracic curve. The parameters of the scoliosis were measured and the correction results were analyzed. Results Totally, 48 patients (7 males, 41 females) were included, with an average age of 14.4 years old and a mean follow-up time of 12.3 months. Thirty and 18 patients were assigned to group A and group B, respectively. The mean preoperative coronal Cobb angles of the thoracic curve were 48.8° and 47.4°, respectively. After surgery, they were corrected to 13.7° and 6.8°, respectively. At final follow-up, they were 17.0° and 9.5°, with an average correction rate of 64.6% and 79.0%, respectively, and the correction rate of group B was significantly higher than that of group A (P=0.003). The mean preoperative coronal Cobb angles of the lumbar curve were 32.6° and 35.2°, respectively. After surgery, they were corrected to 8.6° and 8.3°, respectively. At final follow-up, they were 10.3° and 11.1°, with an average correction rate of 66.8% and 69.9%, respectively, and the correction rate of group B was significantly higher than that of group A (P=0.003). The correction loss of the thoracic curve and lumbar curve in the 2 groups were 3.1° and 1.8°, 2.4° and 2.4°, respectively. No significant difference was noted (both P〉0.05). The decompensation rate at final follow-up in these 2 groups were 4% (1/25) and 7.1% (1/14) respectively, with no significant difference (P〉0.05).展开更多
A new type of linear rotary magnetorheological damper (MRD) is proposed, which consists of a cylinder-type MRD and a screw mechanism to transform a linear motion into revolving motion. It is found that the structure p...A new type of linear rotary magnetorheological damper (MRD) is proposed, which consists of a cylinder-type MRD and a screw mechanism to transform a linear motion into revolving motion. It is found that the structure parameters of MRD have complex relationship with the force of the damper, especially the lead angle, width and radius of the inner rotor. The analyses and simulation calculation of the static magnetic field give some usable data, and experiments of the damping component indicate that the proposed methods is feasible for developing linear rotary MRD.展开更多
Assembly errors have great influence on assembly quality in robotic assembly systems. Error analysis is directed to the propagations and accumula-tions of various errors and their effect on assembly success.Using the ...Assembly errors have great influence on assembly quality in robotic assembly systems. Error analysis is directed to the propagations and accumula-tions of various errors and their effect on assembly success.Using the screw coordinates, assembly errors are represented as 'error twist', the extremely compact expression. According to the law of screw composition, relative position and orientation errors of mating parts are computed and the necessary condition of assembly success is concluded. A new simple method for measuring assembly errors is also proposed based on the transformation law of a screw.Because of the compact representation of error, the model presented for error analysis can be applied to various part- mating types and especially useful for error analysis of complexity assembly.展开更多
文摘Objective To analyze the influence of segmental pedicle screws versus hybrid instrumentation on the correction results in adolescent idiopathic scoliosis patients undergoing posterior selective thoracic fusion. Methods By reviewing the medical records and roentgenograms of adolescent idiopathic scoliosis patients who underwent selective thoracic fusion from February 2000 to January 2007 in our hospital, the patients were divided into 2 groups according to different instrumentation fashions: Group A was hook-screw-rod (hybrid) internal fixation type, Group B was screw-rod (all pedicle screws) internal fixation type, and the screws were used in every segment on the concave side of the thoracic curve. The parameters of the scoliosis were measured and the correction results were analyzed. Results Totally, 48 patients (7 males, 41 females) were included, with an average age of 14.4 years old and a mean follow-up time of 12.3 months. Thirty and 18 patients were assigned to group A and group B, respectively. The mean preoperative coronal Cobb angles of the thoracic curve were 48.8° and 47.4°, respectively. After surgery, they were corrected to 13.7° and 6.8°, respectively. At final follow-up, they were 17.0° and 9.5°, with an average correction rate of 64.6% and 79.0%, respectively, and the correction rate of group B was significantly higher than that of group A (P=0.003). The mean preoperative coronal Cobb angles of the lumbar curve were 32.6° and 35.2°, respectively. After surgery, they were corrected to 8.6° and 8.3°, respectively. At final follow-up, they were 10.3° and 11.1°, with an average correction rate of 66.8% and 69.9%, respectively, and the correction rate of group B was significantly higher than that of group A (P=0.003). The correction loss of the thoracic curve and lumbar curve in the 2 groups were 3.1° and 1.8°, 2.4° and 2.4°, respectively. No significant difference was noted (both P〉0.05). The decompensation rate at final follow-up in these 2 groups were 4% (1/25) and 7.1% (1/14) respectively, with no significant difference (P〉0.05).
文摘A new type of linear rotary magnetorheological damper (MRD) is proposed, which consists of a cylinder-type MRD and a screw mechanism to transform a linear motion into revolving motion. It is found that the structure parameters of MRD have complex relationship with the force of the damper, especially the lead angle, width and radius of the inner rotor. The analyses and simulation calculation of the static magnetic field give some usable data, and experiments of the damping component indicate that the proposed methods is feasible for developing linear rotary MRD.
基金This work is Supported by the National Science Foundation under Grant 863 -512 -9820-04.
文摘Assembly errors have great influence on assembly quality in robotic assembly systems. Error analysis is directed to the propagations and accumula-tions of various errors and their effect on assembly success.Using the screw coordinates, assembly errors are represented as 'error twist', the extremely compact expression. According to the law of screw composition, relative position and orientation errors of mating parts are computed and the necessary condition of assembly success is concluded. A new simple method for measuring assembly errors is also proposed based on the transformation law of a screw.Because of the compact representation of error, the model presented for error analysis can be applied to various part- mating types and especially useful for error analysis of complexity assembly.