Aiming at the stability and others properties of active magnetic bearing (AMB) system influenced by the periodic unbalance stimulation synchronous with rotor rotational speed, a new real-time adaptive feed-forward u...Aiming at the stability and others properties of active magnetic bearing (AMB) system influenced by the periodic unbalance stimulation synchronous with rotor rotational speed, a new real-time adaptive feed-forward unbalance force compensation scheme is proposed based on variable step-size least mean square(LMS) algorithm as the feed-forward compensation controller. The controller can provide some suitable sinusoidal signals to com- pensate the feedback unbalance response signals synchronous with the rotary frequency, then reduce the fluctua- tion of the control currents and weaken the active control of AMB system. The variable step-size proportional to the rotational frequency is deduced by analyzing the principle of normal LMS algorithm and its deficiency in the application of real-time filtering of AMB system. Experimental results show that the new method can implement real-time unbalance force compensation in a wide frequency band, reduce the effect of unbalance stimulant force on the housing of AMB system, and provide convenience to improve rotational speed.展开更多
A time-domain frequencydependent I/Q imbalance compensation scheme based on Golay complementary sequence for receiver is presented. By utilizing property of Golay sequence, the signal and its conjugate interference(im...A time-domain frequencydependent I/Q imbalance compensation scheme based on Golay complementary sequence for receiver is presented. By utilizing property of Golay sequence, the signal and its conjugate interference(image interference)in preamble are separated by correlation and used to estimate I/Q imbalance parameters.After that, a Least Square(LS) estimation of compensation filter is obtained and adopted in the compensation structure. Two applications of the presented algorithm are discussed: we could either estimate the channel along with I/Q imbalance or estimate the imbalance parameter only to maintain a lower cost. Both applications are testified by simulation. The results show that the image interference is significantly suppressed even in poor SNR condition, and the computation cost of the algorithms is low.展开更多
A discontinuity of magnetic circuits according to the end effect is generated in the permanent magnet linear synchronous motor (PMLSM). Due to the unbalanced back electro-motive force (EMF) and impedance produced,...A discontinuity of magnetic circuits according to the end effect is generated in the permanent magnet linear synchronous motor (PMLSM). Due to the unbalanced back electro-motive force (EMF) and impedance produced, unbalanced current is generated. The cireulatin8 current, which is caused by a decrease in the thrust, is generated by the unbalanced current. The optimal design of auxiliary-teeth at the end of the mover was carried out to solve the unbalance of phase by using design of experiment (DOE), and compared with the basic model through finite element analysis (FEA). As a result, the auxiliary-teeth model compensates for the decrease of thrust caused by the unbalanced phase. Also, this model is proven to reduce the detent force by the vibration and noise of the PMLSM and copper loss caused by the circulating current.展开更多
Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmo...Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmonic generation, phase unbalance) down to the prescribed limits. This primarily refers to the presence of non-linear consumers, leading to distortion of the basic parameters of voltage and current, in steady or transient conditions, and therefore the deformation of waveform. One way to reduce the negative feedback effects, especially with inductive loads, is the reactive energy compensation. The paper presents one of the solution for reactive power compensation, applied on the pumping station of public company "Waterworks and Sewerage---Bar", Bar.展开更多
基金Supported by the National Natural Science Foundation of China(50437010)the National High Technology Research and Development Program of China("863"Program)(2006AA05Z205)the Project of Six Talented Peak of Jiangsu Province(07-D-013)~~
文摘Aiming at the stability and others properties of active magnetic bearing (AMB) system influenced by the periodic unbalance stimulation synchronous with rotor rotational speed, a new real-time adaptive feed-forward unbalance force compensation scheme is proposed based on variable step-size least mean square(LMS) algorithm as the feed-forward compensation controller. The controller can provide some suitable sinusoidal signals to com- pensate the feedback unbalance response signals synchronous with the rotary frequency, then reduce the fluctua- tion of the control currents and weaken the active control of AMB system. The variable step-size proportional to the rotational frequency is deduced by analyzing the principle of normal LMS algorithm and its deficiency in the application of real-time filtering of AMB system. Experimental results show that the new method can implement real-time unbalance force compensation in a wide frequency band, reduce the effect of unbalance stimulant force on the housing of AMB system, and provide convenience to improve rotational speed.
基金supported in part by the National High Technology Research and Development Program of China(863 Program)(No.2011AA010201)National Science and Technology Major Project(No.2013ZX03005010)+1 种基金the National Natural Science Foundation of China(NSFC)(No.61371103 and No.60902025)Key Science and Technology Program of Sichuan Province of China(No.2012FZ0119 and No.2012FZ0029)
文摘A time-domain frequencydependent I/Q imbalance compensation scheme based on Golay complementary sequence for receiver is presented. By utilizing property of Golay sequence, the signal and its conjugate interference(image interference)in preamble are separated by correlation and used to estimate I/Q imbalance parameters.After that, a Least Square(LS) estimation of compensation filter is obtained and adopted in the compensation structure. Two applications of the presented algorithm are discussed: we could either estimate the channel along with I/Q imbalance or estimate the imbalance parameter only to maintain a lower cost. Both applications are testified by simulation. The results show that the image interference is significantly suppressed even in poor SNR condition, and the computation cost of the algorithms is low.
基金supported by the Second Stage of Brain Korea 21 Projects and Changwon National University in 2009-2010
文摘A discontinuity of magnetic circuits according to the end effect is generated in the permanent magnet linear synchronous motor (PMLSM). Due to the unbalanced back electro-motive force (EMF) and impedance produced, unbalanced current is generated. The cireulatin8 current, which is caused by a decrease in the thrust, is generated by the unbalanced current. The optimal design of auxiliary-teeth at the end of the mover was carried out to solve the unbalance of phase by using design of experiment (DOE), and compared with the basic model through finite element analysis (FEA). As a result, the auxiliary-teeth model compensates for the decrease of thrust caused by the unbalanced phase. Also, this model is proven to reduce the detent force by the vibration and noise of the PMLSM and copper loss caused by the circulating current.
文摘Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmonic generation, phase unbalance) down to the prescribed limits. This primarily refers to the presence of non-linear consumers, leading to distortion of the basic parameters of voltage and current, in steady or transient conditions, and therefore the deformation of waveform. One way to reduce the negative feedback effects, especially with inductive loads, is the reactive energy compensation. The paper presents one of the solution for reactive power compensation, applied on the pumping station of public company "Waterworks and Sewerage---Bar", Bar.