A complete model of switch-mode plasma cutting power supply and its simulation are developed. The full bridge isolated pulse width modulation (PWM) buck converter in continuous conduction mode (CCM) for high watt plas...A complete model of switch-mode plasma cutting power supply and its simulation are developed. The full bridge isolated pulse width modulation (PWM) buck converter in continuous conduction mode (CCM) for high watt plasma power supply is approached. Reduced ripple current and improved power factor are achieved in the plasma power supply. With a PID control strategy, circuit responses become more stable and faster with low overshoot during load and current changing. The converter achieved high efficiency under 3 to 15kW load conditions.展开更多
This paper presents an analysis of the electric power flows in a hot rolling mill plant using a power quality analyzer and developing simulation models with Matlab-Simulink. The model inputs have been taken from proce...This paper presents an analysis of the electric power flows in a hot rolling mill plant using a power quality analyzer and developing simulation models with Matlab-Simulink. The model inputs have been taken from process data by the process computer of the plant. Data from different rolling campaigns have been analysed. A STATCOM (static synchronous compensator) with a control strategy based on voltage oriented control with d-q coordinates is used as solution to improve the reactive compensation as well as to minimize the voltage fluctuations and sags effect. The overall electric model has been simulated with the STATCOM to check the improvement in the voltage stability and the consumption.展开更多
When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensat...When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensate reactive power following value U* according to the requirements of the Vietnamese power system dispath center, flit harmonic by passive filter... However, it still has some disadvantages of this substation that need to be overcome: use large number of main devices, generate harmonics by itself, cause a lot of active power losses. Thus, the authors have an idea to solve these problems by applying a bidirectional power converter with having difference circuit structure and PWM (pulse width modulation) controller with SVM (space vector modulation) pulse generated section, so compensative current which is created by inductance element can be reserved, adjust continuos and always has full sinusoidal form, not generating harmonic. The benefit of this new solution is to eliminate the three above fundamental disadvantages. This new model is built based on authors' research about BESS (battery energy storage system). The research results have been verified by simulations in Matlab/Simulink software.展开更多
文摘A complete model of switch-mode plasma cutting power supply and its simulation are developed. The full bridge isolated pulse width modulation (PWM) buck converter in continuous conduction mode (CCM) for high watt plasma power supply is approached. Reduced ripple current and improved power factor are achieved in the plasma power supply. With a PID control strategy, circuit responses become more stable and faster with low overshoot during load and current changing. The converter achieved high efficiency under 3 to 15kW load conditions.
文摘This paper presents an analysis of the electric power flows in a hot rolling mill plant using a power quality analyzer and developing simulation models with Matlab-Simulink. The model inputs have been taken from process data by the process computer of the plant. Data from different rolling campaigns have been analysed. A STATCOM (static synchronous compensator) with a control strategy based on voltage oriented control with d-q coordinates is used as solution to improve the reactive compensation as well as to minimize the voltage fluctuations and sags effect. The overall electric model has been simulated with the STATCOM to check the improvement in the voltage stability and the consumption.
文摘When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensate reactive power following value U* according to the requirements of the Vietnamese power system dispath center, flit harmonic by passive filter... However, it still has some disadvantages of this substation that need to be overcome: use large number of main devices, generate harmonics by itself, cause a lot of active power losses. Thus, the authors have an idea to solve these problems by applying a bidirectional power converter with having difference circuit structure and PWM (pulse width modulation) controller with SVM (space vector modulation) pulse generated section, so compensative current which is created by inductance element can be reserved, adjust continuos and always has full sinusoidal form, not generating harmonic. The benefit of this new solution is to eliminate the three above fundamental disadvantages. This new model is built based on authors' research about BESS (battery energy storage system). The research results have been verified by simulations in Matlab/Simulink software.