本文介绍了一种基于ALTERA公司SOPC嵌入式技术的表面肌电信号检测系统。系统将模拟滤波器和数字滤波器结合起来处理采集到的信号,有效地提取了表面肌电信号。
关键词 SOPC 嵌入式技术 表面肌电信号检测
下载PDF
Artifacts of Functional Electrical Stimulation on Electromyograph
2
作者 DUAN Ren-quan ZHANG Ding-guo 《Chinese Journal of Biomedical Engineering(English Edition)》 2014年第4期139-145,共7页
The purpose of this study is to investigate different factors of the artifact in surface electromyography(EMG) signal caused by functional electrical stimulation(FES). The factors investigated include the size of stim... The purpose of this study is to investigate different factors of the artifact in surface electromyography(EMG) signal caused by functional electrical stimulation(FES). The factors investigated include the size of stimulation electrode pads, the amplitude, frequency, and pulse width of the stimulation waveform and the detecting electrode points. We calculate the root mean square(RMS) of EMG signal to analyze the effect of these factors on the M-wave properties. The results indicate that the M-wave mainly depends on the stimulation amplitude and the distribution of detecting electrodes,but not on the other factors. This study can assist the reduction of artifact and the selection of detecting electrode points. 展开更多