A soil temperature control system was designed for sapling study in alpine region and tested in summer, 2009. The system consisted of a power switch, voltage regulator, microcomputer timer, safety relays, temperature ...A soil temperature control system was designed for sapling study in alpine region and tested in summer, 2009. The system consisted of a power switch, voltage regulator, microcomputer timer, safety relays, temperature control device, temperature sensors, heating cables, fireproofing plastic pipes (PVC), 108 heavy-duty plastic containers and seedlings. The heating cables were held in six 2-layer PVC frames with 25 cm wide, 320 cm long and 25 cm high and three 1-layer frames with 25 cm wide and 320 cm long for 15°C soil temperature treatment, half of the 2-layer frames were used for 20°C and 25°C soil temperature treatments, respectively. Each of the frames was installed at each of ditches with 30 cm wide, 330 cm long and 30 cm deep in size. 12 seedling containers with 20 cm top diameter, 18cm bottom diameter and 25 cm high were homogenously placed at each of the ditches, and spaces between the containers were filled with natural soil. The system was economic, and could increase soil temperatures obviously and uniformly, the maximal and minimal standard errors of soil temperatures were ±0.28 and ±0.05°C at 10cm depth in the containers within each of all the ditches. In the system, aboveground environment was natural, diurnal and monthly soil temperatures varied with changing air temperature, the research results may be better to know the eco-physiological and growth responses of alpine saplings/seedlings to soil warming than that in greenhouse, laboratory, infrared heat lamp and open top chamber.展开更多
In the SILER (Seismic-Initiated events risk mitigation in LEad-cooled Reactors) Project, it is interesting to apply seismic isolation technology for the reactor assembly of the fixed base reactor building for ADS (...In the SILER (Seismic-Initiated events risk mitigation in LEad-cooled Reactors) Project, it is interesting to apply seismic isolation technology for the reactor assembly of the fixed base reactor building for ADS (Acceleration Driven System) heavy liquid reactor MYRRHA (Multipurpose Hybrid Research Reactor for High-Tech Application) which contains the most critical safety related components, such as reactor vessel, safe shutdown and control rod mechanisms, primary heat exchangers, primary pumps, spoliation target assembly and fuel assemblies, etc. The purpose of this paper is to investigate the possibility of an application of a partial seismic isolation to the safety critical components only, here, the reactor assembly. This paper presents the preliminary analysis results of the isolated reactor assembly and compares these with those of seismic isolated ADS reactor building. The analysis results show the reduction of the seismic acceleration response but the increase of the relative displacement for the reactor assembly. Some safety issues, especially, coolant's incapable covering the reactor core make difficult to apply for the partial seismic isolation of the ADS reactor assembly due to large relative displacement occurring the partial isolation system. Further study on the partial seismic isolation application of the critical safety components are also discussed.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 30872000 and 41071203)partially supported by the Project of Knowledge Innovation, Chinese Academy of Sciences (No. KZXZ-YW-33)Sichuan Foundation of Excellent Young Scientists (No. 2010JQ0026)
文摘A soil temperature control system was designed for sapling study in alpine region and tested in summer, 2009. The system consisted of a power switch, voltage regulator, microcomputer timer, safety relays, temperature control device, temperature sensors, heating cables, fireproofing plastic pipes (PVC), 108 heavy-duty plastic containers and seedlings. The heating cables were held in six 2-layer PVC frames with 25 cm wide, 320 cm long and 25 cm high and three 1-layer frames with 25 cm wide and 320 cm long for 15°C soil temperature treatment, half of the 2-layer frames were used for 20°C and 25°C soil temperature treatments, respectively. Each of the frames was installed at each of ditches with 30 cm wide, 330 cm long and 30 cm deep in size. 12 seedling containers with 20 cm top diameter, 18cm bottom diameter and 25 cm high were homogenously placed at each of the ditches, and spaces between the containers were filled with natural soil. The system was economic, and could increase soil temperatures obviously and uniformly, the maximal and minimal standard errors of soil temperatures were ±0.28 and ±0.05°C at 10cm depth in the containers within each of all the ditches. In the system, aboveground environment was natural, diurnal and monthly soil temperatures varied with changing air temperature, the research results may be better to know the eco-physiological and growth responses of alpine saplings/seedlings to soil warming than that in greenhouse, laboratory, infrared heat lamp and open top chamber.
文摘In the SILER (Seismic-Initiated events risk mitigation in LEad-cooled Reactors) Project, it is interesting to apply seismic isolation technology for the reactor assembly of the fixed base reactor building for ADS (Acceleration Driven System) heavy liquid reactor MYRRHA (Multipurpose Hybrid Research Reactor for High-Tech Application) which contains the most critical safety related components, such as reactor vessel, safe shutdown and control rod mechanisms, primary heat exchangers, primary pumps, spoliation target assembly and fuel assemblies, etc. The purpose of this paper is to investigate the possibility of an application of a partial seismic isolation to the safety critical components only, here, the reactor assembly. This paper presents the preliminary analysis results of the isolated reactor assembly and compares these with those of seismic isolated ADS reactor building. The analysis results show the reduction of the seismic acceleration response but the increase of the relative displacement for the reactor assembly. Some safety issues, especially, coolant's incapable covering the reactor core make difficult to apply for the partial seismic isolation of the ADS reactor assembly due to large relative displacement occurring the partial isolation system. Further study on the partial seismic isolation application of the critical safety components are also discussed.