To enhance the technology and efficiency of strata injection is a problem to be solved urgently. Because of effected by the rough and poor production conditions of mining and the changeable bearing condition of strata...To enhance the technology and efficiency of strata injection is a problem to be solved urgently. Because of effected by the rough and poor production conditions of mining and the changeable bearing condition of strata, the technological process of injection can not be controlled automatically.The fuzzy controlling technology of the coal strata injection is applied. This is the good way to ensure the effectiveness and efficiency of coal strata injection and to solve the current problems of production and safety in mining industry.展开更多
A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous...A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.展开更多
This paper aims to present a new point of view about the active power measurement, for billing purposes, measured at the PCC (point of common coupling) between the utility and the consumer when harmonic distortions ...This paper aims to present a new point of view about the active power measurement, for billing purposes, measured at the PCC (point of common coupling) between the utility and the consumer when harmonic distortions are involved. Depending on theorigin of it, the active power can result in higher or lower values in comparison to the fundamental component. The consequences are higher costs for the consumer or losses for the electric utility. Using computational simulations and theoretical analysis, these aspects are evaluated and compared.展开更多
文摘To enhance the technology and efficiency of strata injection is a problem to be solved urgently. Because of effected by the rough and poor production conditions of mining and the changeable bearing condition of strata, the technological process of injection can not be controlled automatically.The fuzzy controlling technology of the coal strata injection is applied. This is the good way to ensure the effectiveness and efficiency of coal strata injection and to solve the current problems of production and safety in mining industry.
基金Project(JC200903180555A) supported by Shenzhen City Science and Technology Plan, China
文摘A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.
文摘This paper aims to present a new point of view about the active power measurement, for billing purposes, measured at the PCC (point of common coupling) between the utility and the consumer when harmonic distortions are involved. Depending on theorigin of it, the active power can result in higher or lower values in comparison to the fundamental component. The consequences are higher costs for the consumer or losses for the electric utility. Using computational simulations and theoretical analysis, these aspects are evaluated and compared.