In order to save energy consumption of two-way amplifier forward(AF) relaying with channel estimation error, an energy efficiency enhancement scheme is proposed in this work. Firstly, through the analysis of two-way A...In order to save energy consumption of two-way amplifier forward(AF) relaying with channel estimation error, an energy efficiency enhancement scheme is proposed in this work. Firstly, through the analysis of two-way AF relaying mode with channel estimation error, the resultant instantaneous SNRs at end nodes is obtained. Then, by using a high SNR approximation, outage possibility is acquired and its simple closed-form expression is represented. Specially, for using the energy resource more efficiently, a low-complexity power allocation and transmission mode selection policy is proposed to enhance the energy efficiency of two-way AF relay system. Finally, relay priority region is identified in which cooperative diversity energy gain can be achieved. The computer simulations are presented to verify our analytical results, indicating that the proposed policy outperforms direct transmission by an energy gain of 3 dB at the relative channel estimation error less than 0.001. The results also show that the two-way AF relaying transmission loses the two-way AF relaying transmission loses its superiority to direct transmission in terms of energy efficiency when channel estimation error reaches 0.03.展开更多
The goal of this study is to determine specific guidelines for Iraqi architects to contribute to the design and composition of energy-efficient housing units within the limits of a normal budget, locally available mat...The goal of this study is to determine specific guidelines for Iraqi architects to contribute to the design and composition of energy-efficient housing units within the limits of a normal budget, locally available materials and technologies. These units can provide comfort despite the current energy situation in Iraq. The study is based on a computer simulation for a reference building in Baghdad, which has been selected according to the urban conditions, building legislations, housing market and statistics. The final results displayed the main recommendations and the possibility to achieve up to 50% energy reduction with a pay-back period not exceeding two years in some cases. There are some measures that have big energy saving potential. Yet, some of the measures may require big investment or have some bad environmental impacts. Some other good measures are already being implemented.展开更多
基金Project(IRT0852) supported by the Program for Changjiang Scholars and Innovative Research Team in University,ChinaProject(2012CB316100) supported by the National Basic Research Program of China+2 种基金Projects(61101144,61101145) supported by the National Natural Science Foundation of ChinaProject(B08038) supported by the "111" Project,ChinaProject(K50510010017) supported by the Fundamental Research Funds for the Central Universities,China
文摘In order to save energy consumption of two-way amplifier forward(AF) relaying with channel estimation error, an energy efficiency enhancement scheme is proposed in this work. Firstly, through the analysis of two-way AF relaying mode with channel estimation error, the resultant instantaneous SNRs at end nodes is obtained. Then, by using a high SNR approximation, outage possibility is acquired and its simple closed-form expression is represented. Specially, for using the energy resource more efficiently, a low-complexity power allocation and transmission mode selection policy is proposed to enhance the energy efficiency of two-way AF relay system. Finally, relay priority region is identified in which cooperative diversity energy gain can be achieved. The computer simulations are presented to verify our analytical results, indicating that the proposed policy outperforms direct transmission by an energy gain of 3 dB at the relative channel estimation error less than 0.001. The results also show that the two-way AF relaying transmission loses the two-way AF relaying transmission loses its superiority to direct transmission in terms of energy efficiency when channel estimation error reaches 0.03.
文摘The goal of this study is to determine specific guidelines for Iraqi architects to contribute to the design and composition of energy-efficient housing units within the limits of a normal budget, locally available materials and technologies. These units can provide comfort despite the current energy situation in Iraq. The study is based on a computer simulation for a reference building in Baghdad, which has been selected according to the urban conditions, building legislations, housing market and statistics. The final results displayed the main recommendations and the possibility to achieve up to 50% energy reduction with a pay-back period not exceeding two years in some cases. There are some measures that have big energy saving potential. Yet, some of the measures may require big investment or have some bad environmental impacts. Some other good measures are already being implemented.