The subway stations of urban community type are not only main nodes in the urban traffic network, but also important places for peopled daily life. Widi the rapid development of urban metro and urban economy, the ...The subway stations of urban community type are not only main nodes in the urban traffic network, but also important places for peopled daily life. Widi the rapid development of urban metro and urban economy, the commercial space near tiie subway station has become the focus of urban planning and urban spatial development, and commercial self-oiganization pkys an important role in the development of commercial operations, commercial structures, and commercial scales, so how to make effective use of the inherent laws of the commercial space evolution, and further guide the rational development of community businesses needs more attention and research. This paper takes Chengdu Wannianchang Subway Station as an example to study the evolution stage, influencing factors, evolution characteristics and laws of the neatby commercial space. Moreover, suggestions were put forward such as coordinating competition and collaboration, optimizing space design and management, co-directional self-organization and heter-oiganizations, in order to provide a new reference for the healthy and ordedy development of the neighboring commefdal space near the subway stations of community type.展开更多
This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medi...This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.展开更多
基金Sponsored by Technology Research Program of Sichuan Province of China(2016JY0111)
文摘The subway stations of urban community type are not only main nodes in the urban traffic network, but also important places for peopled daily life. Widi the rapid development of urban metro and urban economy, the commercial space near tiie subway station has become the focus of urban planning and urban spatial development, and commercial self-oiganization pkys an important role in the development of commercial operations, commercial structures, and commercial scales, so how to make effective use of the inherent laws of the commercial space evolution, and further guide the rational development of community businesses needs more attention and research. This paper takes Chengdu Wannianchang Subway Station as an example to study the evolution stage, influencing factors, evolution characteristics and laws of the neatby commercial space. Moreover, suggestions were put forward such as coordinating competition and collaboration, optimizing space design and management, co-directional self-organization and heter-oiganizations, in order to provide a new reference for the healthy and ordedy development of the neighboring commefdal space near the subway stations of community type.
文摘This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.