Recently, resonant AC/DC converter has been accepted by the industry. However, the efficiency will be decreased at light load. So, a novel topology with critical controlling mode combined with resonant ones is propose...Recently, resonant AC/DC converter has been accepted by the industry. However, the efficiency will be decreased at light load. So, a novel topology with critical controlling mode combined with resonant ones is proposed in this paper. The new topology can correspond to a 90 plus percent of power converting. So,a novel topology of an state of art integrated circuit, which can be used as power management circuit, has been designed based on the above new topology. A simulator which is specifically suitable for the power controller has been founded in this work and it has been used for the simulation of the novel architecture and the proposed integrated circuit.展开更多
International standards impose several constraints concerning the electric power quality and require that the harmonic content of the line current of grid connected equipment is below assigned limits; for this reason,...International standards impose several constraints concerning the electric power quality and require that the harmonic content of the line current of grid connected equipment is below assigned limits; for this reason, operating of AC-DC converters with high power factor and low line current distortion has become essential. In this paper, the prototypal realization of a three-phase AC-DC 48 V power electronic converter for telecom system supplying is described and experimental testing results are discussed. The main constraints in the power supply design are the required power density of about 900 W per dm3 as well as the absence of the neutral wire in the supply grid. The carried out investigation is focused on three-level power converter configurations which are considered in order to reduce voltage rating of power switches. As a result of the reduced voltage, low on-resistance metal-oxide-semiconductor field effect transistors can be used in the power stage, solution which allows to achieve improved efficiency as well as increased switching frequency with respect to the insulated gate bipolar transistors based two-level topologies.展开更多
Cooling water is an important part in a Spallation Neutron Source target cooling system, but the unstable vortexes at the exits of the slits between every two tungsten target slices have a negative impact on the stabl...Cooling water is an important part in a Spallation Neutron Source target cooling system, but the unstable vortexes at the exits of the slits between every two tungsten target slices have a negative impact on the stable running of the target system. We apply the field synergy principle for fluid flow to obtain the optimal flow field, which has a uniform velocity distribution without eddy, and then, optimize the geometrical structure of the cooling water flow channel based on the optimal flow field. The results show that when the cooling water flows in the optimized channel, the eddy sizes decrease, the time fluctuations of velocity and pressure almost vanish, and the volume flow rates of the cooling water in each parallel slit are uniform. Therefore, it effectively improves the running stability of the target system with the premise of satisfying the target heat load.展开更多
基金supported by Program for New Century Excellent Talents in University(NCET)(2008)Funding Project for Academic Human Resources Development in Institutions of Higher Learning Under the Jurisdiction of Beijing Municipality+1 种基金 (PHR(IHLB)) and Beijing Novel Research Star(2005B01)Ministry of Beijing Science and Technology
文摘Recently, resonant AC/DC converter has been accepted by the industry. However, the efficiency will be decreased at light load. So, a novel topology with critical controlling mode combined with resonant ones is proposed in this paper. The new topology can correspond to a 90 plus percent of power converting. So,a novel topology of an state of art integrated circuit, which can be used as power management circuit, has been designed based on the above new topology. A simulator which is specifically suitable for the power controller has been founded in this work and it has been used for the simulation of the novel architecture and the proposed integrated circuit.
文摘International standards impose several constraints concerning the electric power quality and require that the harmonic content of the line current of grid connected equipment is below assigned limits; for this reason, operating of AC-DC converters with high power factor and low line current distortion has become essential. In this paper, the prototypal realization of a three-phase AC-DC 48 V power electronic converter for telecom system supplying is described and experimental testing results are discussed. The main constraints in the power supply design are the required power density of about 900 W per dm3 as well as the absence of the neutral wire in the supply grid. The carried out investigation is focused on three-level power converter configurations which are considered in order to reduce voltage rating of power switches. As a result of the reduced voltage, low on-resistance metal-oxide-semiconductor field effect transistors can be used in the power stage, solution which allows to achieve improved efficiency as well as increased switching frequency with respect to the insulated gate bipolar transistors based two-level topologies.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51006060, 51036003)the Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No.201150)
文摘Cooling water is an important part in a Spallation Neutron Source target cooling system, but the unstable vortexes at the exits of the slits between every two tungsten target slices have a negative impact on the stable running of the target system. We apply the field synergy principle for fluid flow to obtain the optimal flow field, which has a uniform velocity distribution without eddy, and then, optimize the geometrical structure of the cooling water flow channel based on the optimal flow field. The results show that when the cooling water flows in the optimized channel, the eddy sizes decrease, the time fluctuations of velocity and pressure almost vanish, and the volume flow rates of the cooling water in each parallel slit are uniform. Therefore, it effectively improves the running stability of the target system with the premise of satisfying the target heat load.