期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
滴灌工程系统的施工安装
1
作者 宋艳军 《现代农业》 2012年第3期89-90,共2页
文章主要论述了滴灌工程系统的施工安装及试压运行。
关键词 滴灌工程系统 施工安装 试压运行
下载PDF
Study of High Efficiency Membrane Pilot Test for Membrane Design Optimisation in Order to Reduce the Electrical Consumption
2
作者 Federico Antonio Leon Alejandro Ramos 《Journal of Energy and Power Engineering》 2016年第10期628-633,共6页
Regarding the studies of other authors about energy performance of a reverse osmosis desalination plant operating with variable pressure; about desalination efficiency in their different recent articles, we continued ... Regarding the studies of other authors about energy performance of a reverse osmosis desalination plant operating with variable pressure; about desalination efficiency in their different recent articles, we continued working in this way researching in a real seawater reverse osmosis plant following the items below. The objectives of this test are to get the minimum electrical consumption and energy costs for the operation of a sea water desalination plant using membranes. We need to compare the performance of the different membranes manufacturer's and to determine, under this new thermal scenario, the optimal configuration to get the water quality and quantity needs with the minimum energy consumption. 展开更多
关键词 Minimum energy consumption energetic efficiency high efficiency membrane energy costs.
下载PDF
Performance analysis and improvement of a high flow coefficient centrifugal compressor 被引量:4
3
作者 WANG YongSheng WANG Kai +2 位作者 LIN Feng NIE ChaoQun ENGEDA Abraham 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第8期1647-1657,共11页
Very high flow coefficient centrifugal compressor stages are mostly performance of this type of stages is critical to the entire centrifugal applied as the first stages of multistage compressors. The compressors, but ... Very high flow coefficient centrifugal compressor stages are mostly performance of this type of stages is critical to the entire centrifugal applied as the first stages of multistage compressors. The compressors, but surprisingly little related information is available in the open literature. A centrifugal compressor with high inlet flow coefficient of 0.2, presenting a narrow operating range and unstable running situation even at design speed during the test, is investigated here. To reveal flow details in this centrifugal compressor, numerical simulations have been carried out and indicate that excessive impeller flow diffusion results in the poor performance of this centrifugal compressor. With the same inlet flow coefficient, six redesign cases coming from an in-house one-dimensional analysis program are proposed together with impeller trimming and equal flow area design method for corresponding vaneless diffuser. Performance comparison among these redesign centrifugal compressors is presented and the most suitable one is recommended for test in the future. In addition, three redesign cases with lower inlet flow coefficient developed by means of flow trimming are shown in the end to satisfy potential application areas. Finally, the results in this study can provide valuable reference information for multistage centrifugal compressor design. 展开更多
关键词 centrifugal compressor very high flow coefficient IMPROVEMENT impeller trimming
原文传递
上一页 1 下一页 到第