In late 2001, the Object Management Group issued a Request for Proposal to develop a testing profile for UML 2.0. In June 2003, the work on the UML 2.0 Testing Profile was finally adopted by the OMG. Since March 2004,...In late 2001, the Object Management Group issued a Request for Proposal to develop a testing profile for UML 2.0. In June 2003, the work on the UML 2.0 Testing Profile was finally adopted by the OMG. Since March 2004, it has become an official standard of the OMG. The UML 2.0 Testing Profile provides support for UML based model-driven testing. This paper introduces a methodology on how to use the testing profile in order to modify and extend an existing UML design model for test issues. The application of the methodology will be explained by applying it to an existing UML Model for a Bluetooth device.展开更多
The objective of this paper is to evaluate the Vialit Adhesion Test and its potential for use within performance oriented specifications for seal treatments. Multiple aggregates and emulsions are evaluated with existi...The objective of this paper is to evaluate the Vialit Adhesion Test and its potential for use within performance oriented specifications for seal treatments. Multiple aggregates and emulsions are evaluated with existing test methods and with modified equipment and methods. The results indicate the current test tray is inadequate and that a thicker tray provides better results. Conditioning that incorporated either freeze times between 4 to 8 hours and/or freeze thaw cycles were also found to be improvements to the current conditioning methods. The specified mass of the steel spheres used during the test may be too restrictive in that more economical spheres were tested and did not show differences in aggregate loss.展开更多
文摘In late 2001, the Object Management Group issued a Request for Proposal to develop a testing profile for UML 2.0. In June 2003, the work on the UML 2.0 Testing Profile was finally adopted by the OMG. Since March 2004, it has become an official standard of the OMG. The UML 2.0 Testing Profile provides support for UML based model-driven testing. This paper introduces a methodology on how to use the testing profile in order to modify and extend an existing UML design model for test issues. The application of the methodology will be explained by applying it to an existing UML Model for a Bluetooth device.
文摘The objective of this paper is to evaluate the Vialit Adhesion Test and its potential for use within performance oriented specifications for seal treatments. Multiple aggregates and emulsions are evaluated with existing test methods and with modified equipment and methods. The results indicate the current test tray is inadequate and that a thicker tray provides better results. Conditioning that incorporated either freeze times between 4 to 8 hours and/or freeze thaw cycles were also found to be improvements to the current conditioning methods. The specified mass of the steel spheres used during the test may be too restrictive in that more economical spheres were tested and did not show differences in aggregate loss.