主变压器现场局部放电试验方案研究与应用
1
作者 申雁鹏 《中国设备工程》 2023年第S02期20-23,共4页
针对主变压器的技术性能改进项目任务,在现场安装投入运行前需要进行局部放电试验。依据国家标准并结合现场实际情况,分析制定了现场局部放电试验方案;对在现场实施局部放电试验存在的主变高压出线端绝缘问题进行了研究,制定多种解决方... 针对主变压器的技术性能改进项目任务,在现场安装投入运行前需要进行局部放电试验。依据国家标准并结合现场实际情况,分析制定了现场局部放电试验方案;对在现场实施局部放电试验存在的主变高压出线端绝缘问题进行了研究,制定多种解决方案进行详细的对比分析,新设计定制专用的试验套筒来解决高压端绝缘问题,有利于主变单独进行试验,不占用大修换相工期;并对主变在现场进行局部放电的具体试验方法及试验步骤进行了描述;介绍了试验结果的分析方法与评判标准。最后采用研究制定的方案,在现场顺利实施完成了多台次主变的局部放电试验,其中发现2台主变存在缺陷,得以及时处理,避免了隐患带入运行中。试验的顺利完成,充分验证了试验套筒方案完全满足试验电压的要求,且使用方便,安全可靠,解决了工程现场的实际难题。 展开更多
关键词 主变压器 分析 局部放电试验 试验套筒 放电量
下载PDF
Cyclic test and numerical study of seismic performance of precast segmental concrete double-columns
2
作者 ZOU Shuang WENLIUHAN Hei-sha +2 位作者 MAO Yong-ping YU Bi-peng ZHANG Chong-bin 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第8期2502-2512,共11页
The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and th... The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and the PC pier of the new railway project from Hetian to Ruoqiang are taken into consideration.Two kinds of 1/5-scale assembled double-column specimens are made,and the quasi-static tests are carried out.The overall seismic performance of the two spliced piers is studied,and compared in terms of failure mechanism,bearing capacity,ductility,stiffness and energy dissipation capacity.The results show that the failure modes of both GS pier and PC pier are characterized by bending.However,the specific failure location and form are different.The GS pier presents a complete hysteretic curve,large equivalent stiffness and strong energy dissipation capacity.The hysteretic area of the PC pier is small.However,it has good self-reset ability and quasi-static residual displacement.Finite element models are set up using DispBeamColumn fiber elements and ZeroLength elements.The models that are calibrated with the test data can effectively simulate the damage development under monotonic loading.The load−displacement curves are in good agreement with the backbone curves of the test results. 展开更多
关键词 pseudo static test seismic performance prestressed precast segmental concrete double-column piers steel sleeve connection precast concrete prestressed steel
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部