The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a g...The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a great deal of investigation is carried out in China. This paper summarizes a program to improve the measurement accuracy of wind tunnel balances. In the program, the investigation is carried out in three aspects (1) designing a drag component of the balance in low interactions (2) choosing high quality foil strain gauges with temperature self-compensation (3) choosing the excellent gauges and mounting them meticulously. As an example, these research achievements are applied in a φ18 six component balance. The measurement accuracy of a GB-04 standard model in a transonic wind tunnel with the φ18 six component balance comes up to the advanced world standard.展开更多
Large diameter fans with low solidity are widely used in automotive application for engine cooling. Their designs with small chord length help reducing the torque on the electrical motor and providing a good aerodynam...Large diameter fans with low solidity are widely used in automotive application for engine cooling. Their designs with small chord length help reducing the torque on the electrical motor and providing a good aerodynamic compromise between several operating conditions, some of these being at high flow rate. Their global performances are measured according to the ISO standard DP 5801, which allows comparison of results from different facilities. However, some variations in global performances are observed when considering results from two different test rigs. On a fan selected for the purpose of this study, up to 6 % of efficiency is lost on the worst case. As efficiency is more than ever a key factor to select a component, some experimental and numerical investigations were conducted to analyze the fan behavior on each facility. Two sets of measurement and simulation are performed and compared. Geometries considered for the domain of computation include the test rig plenum, the torquemeter, the ground and a large domain for the atmospheric conditions. The exact fan geometry with tip clearance and under-hub ribs is also considered. Numerical results show a good agreement with experiment in both cases when convergence is reached and for low flow rate when computations are switched to unsteady mode. Comparisons show that simulations are able to capture the different fan behaviors depending on the confguration and those efficiency losses previously observed are correctly predicted. These results are further analyzed to perform some post-processing. Blade loading remains identical for both cases but disparities appear in the wake and its interaction with the surrounding. Tiny details that are often neglected during experiment and/or simulation appear to be the cause of slight variations. Position of the torquemeter and shape of the plenum are among the parameters that various and that have cumulative effects. Efficiency being a ration of pressure and torque, variations are rather important. Finally, these results are discussed in terms of rules for conception and a new geometry less sensible to loss of efficiency is proposed.展开更多
A wind tunnel test was conducted for a large steel gymnasium structure. Simultaneous pressure measurements were made on its entire ellipsoidal roof in a simulated suburban boundary layer flow field. Special attention ...A wind tunnel test was conducted for a large steel gymnasium structure. Simultaneous pressure measurements were made on its entire ellipsoidal roof in a simulated suburban boundary layer flow field. Special attention is paid to the charaeteristics of fluctuating wind pressures in different zones on the roof. Some selected results are presented: 1) correlations between fluctuating wind pressures on both roof surfaces, 2) eigenvalues and eigenvectors of covariance matrices of the fluctuating wind pressures, 3) probability distributions of the fluctuating wind pressures, and 4) statistical characteristics of peak factor. Furthermore, the applicability of the quasi-steady approach is discussed in detail. Based on the results, an empirical formula for estimating the minimum pressure coefficients, using a peak factor approach, is presented. Comparison of the minimum pressure coefficients determined by the proposed formula and those obtained from the wind tunnel tests is made to examine the applicability and accuracy of the proposed formula.展开更多
To investigate the fan performance of air conditioning system, two different configuration fan test systems are designed. All scale simulation of the two systems provide the basis for design and improvement of air con...To investigate the fan performance of air conditioning system, two different configuration fan test systems are designed. All scale simulation of the two systems provide the basis for design and improvement of air conditioning system fans to improve the internal flow, increase air volume, and reduce the noise. The conclusion that disturbance on flow of nuzzle outlet is the main sources of measurement error about 5% can be proved by the comparative analysis of the results between computation and experiment. Through Optimization Design of Partial Structure they all meet the industry standard, measurement error less than 1.5%.展开更多
文摘The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a great deal of investigation is carried out in China. This paper summarizes a program to improve the measurement accuracy of wind tunnel balances. In the program, the investigation is carried out in three aspects (1) designing a drag component of the balance in low interactions (2) choosing high quality foil strain gauges with temperature self-compensation (3) choosing the excellent gauges and mounting them meticulously. As an example, these research achievements are applied in a φ18 six component balance. The measurement accuracy of a GB-04 standard model in a transonic wind tunnel with the φ18 six component balance comes up to the advanced world standard.
文摘Large diameter fans with low solidity are widely used in automotive application for engine cooling. Their designs with small chord length help reducing the torque on the electrical motor and providing a good aerodynamic compromise between several operating conditions, some of these being at high flow rate. Their global performances are measured according to the ISO standard DP 5801, which allows comparison of results from different facilities. However, some variations in global performances are observed when considering results from two different test rigs. On a fan selected for the purpose of this study, up to 6 % of efficiency is lost on the worst case. As efficiency is more than ever a key factor to select a component, some experimental and numerical investigations were conducted to analyze the fan behavior on each facility. Two sets of measurement and simulation are performed and compared. Geometries considered for the domain of computation include the test rig plenum, the torquemeter, the ground and a large domain for the atmospheric conditions. The exact fan geometry with tip clearance and under-hub ribs is also considered. Numerical results show a good agreement with experiment in both cases when convergence is reached and for low flow rate when computations are switched to unsteady mode. Comparisons show that simulations are able to capture the different fan behaviors depending on the confguration and those efficiency losses previously observed are correctly predicted. These results are further analyzed to perform some post-processing. Blade loading remains identical for both cases but disparities appear in the wake and its interaction with the surrounding. Tiny details that are often neglected during experiment and/or simulation appear to be the cause of slight variations. Position of the torquemeter and shape of the plenum are among the parameters that various and that have cumulative effects. Efficiency being a ration of pressure and torque, variations are rather important. Finally, these results are discussed in terms of rules for conception and a new geometry less sensible to loss of efficiency is proposed.
基金Project(50978063) supported by the National Science Foundation of ChinaProject(NCET-09-0082) supported by the Program for New Century Excellent Talents in Chinese UniversitiesProject(121072) supported by the Fok Ying-Tong Education Foundation for Young Teachers in the Higher Education Institutions of China
文摘A wind tunnel test was conducted for a large steel gymnasium structure. Simultaneous pressure measurements were made on its entire ellipsoidal roof in a simulated suburban boundary layer flow field. Special attention is paid to the charaeteristics of fluctuating wind pressures in different zones on the roof. Some selected results are presented: 1) correlations between fluctuating wind pressures on both roof surfaces, 2) eigenvalues and eigenvectors of covariance matrices of the fluctuating wind pressures, 3) probability distributions of the fluctuating wind pressures, and 4) statistical characteristics of peak factor. Furthermore, the applicability of the quasi-steady approach is discussed in detail. Based on the results, an empirical formula for estimating the minimum pressure coefficients, using a peak factor approach, is presented. Comparison of the minimum pressure coefficients determined by the proposed formula and those obtained from the wind tunnel tests is made to examine the applicability and accuracy of the proposed formula.
基金supported by grants from the National Natural Science Foundation of China (No.50976044)
文摘To investigate the fan performance of air conditioning system, two different configuration fan test systems are designed. All scale simulation of the two systems provide the basis for design and improvement of air conditioning system fans to improve the internal flow, increase air volume, and reduce the noise. The conclusion that disturbance on flow of nuzzle outlet is the main sources of measurement error about 5% can be proved by the comparative analysis of the results between computation and experiment. Through Optimization Design of Partial Structure they all meet the industry standard, measurement error less than 1.5%.