期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
基于分区电网的多机进相调压效益探析 被引量:4
1
作者 韦延方 卫志农 +1 位作者 孙国强 王成亮 《华东电力》 北大核心 2011年第9期1434-1438,共5页
发电机进相运行是解决系统低谷运行时枢纽点电压偏高的有效手段。针对江苏省2010年实际背景分区电网,选择若干组已投运的机组,以分类分区研究单机进相的调压作用为基础,对多机进相运行进行仿真,分析进相运行对分区关键母线电压的影响和... 发电机进相运行是解决系统低谷运行时枢纽点电压偏高的有效手段。针对江苏省2010年实际背景分区电网,选择若干组已投运的机组,以分类分区研究单机进相的调压作用为基础,对多机进相运行进行仿真,分析进相运行对分区关键母线电压的影响和对系统电压的调节作用,并校验多机进相运行时系统的暂态稳定性,探讨分区内多机进相运行的调压能力。 展开更多
关键词 分区电网 多机进相 调压系数 暂态校验
原文传递
A Novel CMOS Voltage Reference Based on Threshold Voltage Difference Between p-Type and n-Type MOSFETs
2
作者 孔明 郭健民 +1 位作者 张科 李文宏 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2007年第10期1546-1550,共5页
A novel MOS-only voltage reference is presented,which is based on the threshold voltage difference between p-type and n-type MOSFETs. Its precision is improved by the cancellation of the process variation. The referen... A novel MOS-only voltage reference is presented,which is based on the threshold voltage difference between p-type and n-type MOSFETs. Its precision is improved by the cancellation of the process variation. The reference has been successfully implemented in a Chartered 0.35μm CMOS process. The occupied chip area is 0. 022mm^2. Measurements indicate that without trimming, the average output voltage error is 6mV at room temperature compared with the simulation result. The temperature coefficient is 180ppm/℃ in the worst case in the temperature range of 0 to 100℃ ,and the line regulation is ± 1.1%. The reference is applied in an adaptive power MOSFET driver. 展开更多
关键词 MOS-only voltage reference threshold voltage temperature coefficient line regulation
下载PDF
Theoretical research on aggregative dynamic pressure damper 被引量:1
3
作者 胡军华 《Journal of Chongqing University》 CAS 2009年第3期188-194,共7页
To broaden the frequency width and increase the damping coefficient of a dynamic pressure damper, we designed an aggregative dynamic pressure damper (ADPD). Combined with the advantages of traditional dynamic pressure... To broaden the frequency width and increase the damping coefficient of a dynamic pressure damper, we designed an aggregative dynamic pressure damper (ADPD). Combined with the advantages of traditional dynamic pressure dampers (TDPD), ADPD can not only increase the damping coefficient in wide frequency range for valve control system, but also absorb partial pressure pulsations and impacts in the low and high frequency fields. Based on the theoretical research and the analysis compared with TDPD, we concluded that the ADPD was superior to the TDPD in the middle high frequency field, and the main parameters influencing the performance of the damper were the damping stiffness, orifice flow coefficient, pre-charge pressure, and the volume of the damper accumulator. 展开更多
关键词 aggregative dynamic pressure damper damping coefficient pressure pulsation
下载PDF
Numerical Simulation on a Throttle Governing System with Hydraulic Butterfly Valves in a Marine Environment 被引量:2
4
作者 万会雄 方俊 黄辉 《Journal of Marine Science and Application》 2010年第4期403-409,共7页
Hydraulic butterfly valves have been widely applied in marine engineering because of their large switching torque, low pressure loss and suitability for large and medium diameter pipelines. Due to control problems res... Hydraulic butterfly valves have been widely applied in marine engineering because of their large switching torque, low pressure loss and suitability for large and medium diameter pipelines. Due to control problems resulting from switching angular speeds of the hydraulic butterfly valve, a throttle-governing control mode has been widely adopted, and detailed analysis has been carried out worldwide on the structural principle concerning speed-regulation and the load torque on the shaft while opening or closing a hydraulic butterfly valve. However relevant reports have yet been published on the change law, the error and the influencing factors of the rotational angular velocity of the hydraulic butterfly valve while opening and closing. In this article, research was based on some common specifications of a hydraulic butterfly valve with a symmetrical valve flap existing in a marine environment. The throttle governing system supplied by the accumulator to achieve the switching of the hydraulic control valve was adopted, and the mathematical models of the system were established in the actual conditions while the numerical simulations took place. The simulation results and analysis show that the rotational angular velocity and the error of the hydraulic butterfly valve while switching is influenced greatly by the drainage amount of the accumulator, resulting in pressure loss in the pipeline, the temperature of hydraulic medium and the load of the hydraulic butterfly valve. The simulation results and analysis provide a theoretical basis for the choice of the total capacity of the accumulator and pipeline diameters in a throttle governing system with a hydraulic butterfly valve.It also determines the type and specification of the hydraulic butterfly valve and the design of motion parameters of the transported fluid. 展开更多
关键词 hydraulic butterfly valve throttle governing switching angular speed load characteristics numerical simulation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部