Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera...Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.展开更多
Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the...Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results.展开更多
The paper presents selected experience of the authors resulting from the optimization tests of double-regulated water turbines. Among the methods for measuring the discharge through the turbine used in such tests, par...The paper presents selected experience of the authors resulting from the optimization tests of double-regulated water turbines. Among the methods for measuring the discharge through the turbine used in such tests, particular attention was paid to index methods allowing to measure the relative discharge through the turbine-the index current meter method and the methods based on measuring the differential pressure between two points properly located at the turbine flow system (i.e., Winter-Kennedy method). These methods contribute to effective reduction of the cost of optimizing the turbine that is extremely important for small hydropower plants regarding installed capacity. The paper presents selected examples of the optimization tests and experiences that arise from these tests.展开更多
文摘Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.
文摘Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results.
文摘The paper presents selected experience of the authors resulting from the optimization tests of double-regulated water turbines. Among the methods for measuring the discharge through the turbine used in such tests, particular attention was paid to index methods allowing to measure the relative discharge through the turbine-the index current meter method and the methods based on measuring the differential pressure between two points properly located at the turbine flow system (i.e., Winter-Kennedy method). These methods contribute to effective reduction of the cost of optimizing the turbine that is extremely important for small hydropower plants regarding installed capacity. The paper presents selected examples of the optimization tests and experiences that arise from these tests.