A new type of a heat pump driven three-stage lithium bromide liquid desiccant deep dehumidification processor is presented,which can dehumidify the outdoor humid air to a rather dry state,even when there is no availab...A new type of a heat pump driven three-stage lithium bromide liquid desiccant deep dehumidification processor is presented,which can dehumidify the outdoor humid air to a rather dry state,even when there is no available indoor exhaust air.The test results show that with an outdoor air temperature of 28 to 31 ℃ and an outdoor air humidity ratio of 11 to 14 g/kg,the supply air temperature and the supply air humidity ratio are 1.6 to 2.6 ℃ and 2.6 to 3.0 g/kg,respectively,and the coefficient of performance(COP)of the processor is 1.8.During the test,a liquid pipeline link problem leading to mixture losses of hot and cold liquid desiccants is found.These pipelines are modified.Then,the performance of the modified processor is investigated.And the experimental results show that with an outdoor air temperature of 25 to 32 ℃ and an outdoor air humidity ratio of 18 to 21 g/kg,the supply air temperature and the supply air humidity ratio are 3.2 to 4.0 ℃ and 3.4 to 3.6 g/kg,respectively,and the COP is 2.8.Finally,a mathematical model of the processor is established.The comparison of the simulation results and the test results of the processor exhibits that the pipeline modification improves the performance by about 20%.展开更多
This work was aimed to study the relative floatability of phosphate flotation by means of kinetic analysis.The relative floatability is important to determine how selectively the phosphate is separated from its impuri...This work was aimed to study the relative floatability of phosphate flotation by means of kinetic analysis.The relative floatability is important to determine how selectively the phosphate is separated from its impurities. The effects of pulp pH, solid content, reagents dosage(depressant, collector and co-collector) and conditioning time were investigated on the ratio of the modified rate constant of phosphate to the modified rate constant of iron(relative floatability). The results showed that a large dosage of depressant associated with a low value of collector resulted in a better relative floatability. Increasing the co-collector dosage, conditioning time and pH increased the relative floatability up to a certain value and thereafter resulted in diminishing the relative floatability. Meanwhile, the results indicated that increment of solid concentration increased the relative floatability in range investigated. It was also found that that maximum relative floatability(16.05) could be obtained in pulp pH, 9.32, solid percentage, 30,depressant dosage, 440 g/t, collector dosage, 560 g/t, co-collector dosage, 84.63 g/t and conditioning time,9.43 min.展开更多
In this paper,the average dose level is introduced in an environment and area when BEPCⅡis debugged. The typical dose graphs are offered when the electronic storage ring is debugged and works in the synchrotron radia...In this paper,the average dose level is introduced in an environment and area when BEPCⅡis debugged. The typical dose graphs are offered when the electronic storage ring is debugged and works in the synchrotron radiation mode.At the same time,some suggestions about radiation protection are presented.All the data indicate that the main and local part shielding satisfy the need and attain the design target.展开更多
基金The National Natural Science Foundation of China(No.50778094)
文摘A new type of a heat pump driven three-stage lithium bromide liquid desiccant deep dehumidification processor is presented,which can dehumidify the outdoor humid air to a rather dry state,even when there is no available indoor exhaust air.The test results show that with an outdoor air temperature of 28 to 31 ℃ and an outdoor air humidity ratio of 11 to 14 g/kg,the supply air temperature and the supply air humidity ratio are 1.6 to 2.6 ℃ and 2.6 to 3.0 g/kg,respectively,and the coefficient of performance(COP)of the processor is 1.8.During the test,a liquid pipeline link problem leading to mixture losses of hot and cold liquid desiccants is found.These pipelines are modified.Then,the performance of the modified processor is investigated.And the experimental results show that with an outdoor air temperature of 25 to 32 ℃ and an outdoor air humidity ratio of 18 to 21 g/kg,the supply air temperature and the supply air humidity ratio are 3.2 to 4.0 ℃ and 3.4 to 3.6 g/kg,respectively,and the COP is 2.8.Finally,a mathematical model of the processor is established.The comparison of the simulation results and the test results of the processor exhibits that the pipeline modification improves the performance by about 20%.
基金the phosphate Esfordi MineShahrood University of Technology for their support during this research
文摘This work was aimed to study the relative floatability of phosphate flotation by means of kinetic analysis.The relative floatability is important to determine how selectively the phosphate is separated from its impurities. The effects of pulp pH, solid content, reagents dosage(depressant, collector and co-collector) and conditioning time were investigated on the ratio of the modified rate constant of phosphate to the modified rate constant of iron(relative floatability). The results showed that a large dosage of depressant associated with a low value of collector resulted in a better relative floatability. Increasing the co-collector dosage, conditioning time and pH increased the relative floatability up to a certain value and thereafter resulted in diminishing the relative floatability. Meanwhile, the results indicated that increment of solid concentration increased the relative floatability in range investigated. It was also found that that maximum relative floatability(16.05) could be obtained in pulp pH, 9.32, solid percentage, 30,depressant dosage, 440 g/t, collector dosage, 560 g/t, co-collector dosage, 84.63 g/t and conditioning time,9.43 min.
文摘In this paper,the average dose level is introduced in an environment and area when BEPCⅡis debugged. The typical dose graphs are offered when the electronic storage ring is debugged and works in the synchrotron radiation mode.At the same time,some suggestions about radiation protection are presented.All the data indicate that the main and local part shielding satisfy the need and attain the design target.