Solid-state wave gyroscope is one kind of high-performance vibrating gyroscopes. The present work develops a new type of solid-state wave gyroscope—a ring vibrating gyroscope driven by piezo-electrodes located on the...Solid-state wave gyroscope is one kind of high-performance vibrating gyroscopes. The present work develops a new type of solid-state wave gyroscope—a ring vibrating gyroscope driven by piezo-electrodes located on the sidewall of the structure. It has advantages of large vibrating amplitude, high energy conversion efficiency and compact structure. The working principle of the piezoelectric ring vibrating gyroscope is based on the inertia effect of the standing wave in the axisymmetric resonator caused by Coriolis force. The finite element method(FEM) analysis has been implemented to characterize the ring type resonator. The prototypal gyroscope was manufactured and has been trimmed by mechanical way. The harmonic response of the ring vibrating gyroscope has been tested. The resonating frequency of the ring type resonator is 3715.6 Hz and the frequency split of the two working modes before trimming was about 5 Hz and was reduced to sub-0.01 Hz after trimming procedure. The Q-factor of the ring type resonator was 2504. Then, the turntable experiment was implemented. The measured scale factor k is 9.24 m V/[(°)·s] and the full scale range of the gyroscope is larger than ±300(°)/s.展开更多
In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator a...In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation.展开更多
The notes here presented are of the modifications introduced in the application of WKB method.Theproblems of two-and three-dimensional harmonic oscillator potential are revisited by WKB and the new formulationof quant...The notes here presented are of the modifications introduced in the application of WKB method.Theproblems of two-and three-dimensional harmonic oscillator potential are revisited by WKB and the new formulationof quantization rule respectively.It is found that the energy spectrum of the radial harmonic oscillator,which isreproduced exactly by the standard WKB method with the Langer modification,is also reproduced exactly without theLanger modification via the new quantization rule approach.An alternative way to obtain the non-integral Maslov indexfor three-dimensional harmonic oscillator is proposed.展开更多
基金Projects(51335011,51275522)supported by the National Natural Science Foundation of ChinaProject(HPCM-2013-08)supported by Key Lab Open Foundation of State Key Laboratory of High Performance(Complex Manufacturing),Central South University,China
文摘Solid-state wave gyroscope is one kind of high-performance vibrating gyroscopes. The present work develops a new type of solid-state wave gyroscope—a ring vibrating gyroscope driven by piezo-electrodes located on the sidewall of the structure. It has advantages of large vibrating amplitude, high energy conversion efficiency and compact structure. The working principle of the piezoelectric ring vibrating gyroscope is based on the inertia effect of the standing wave in the axisymmetric resonator caused by Coriolis force. The finite element method(FEM) analysis has been implemented to characterize the ring type resonator. The prototypal gyroscope was manufactured and has been trimmed by mechanical way. The harmonic response of the ring vibrating gyroscope has been tested. The resonating frequency of the ring type resonator is 3715.6 Hz and the frequency split of the two working modes before trimming was about 5 Hz and was reduced to sub-0.01 Hz after trimming procedure. The Q-factor of the ring type resonator was 2504. Then, the turntable experiment was implemented. The measured scale factor k is 9.24 m V/[(°)·s] and the full scale range of the gyroscope is larger than ±300(°)/s.
文摘In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation.
基金National Natural Science Foundation of China under Grant No.10747130the Foundation of East China University of Science and Technology
文摘The notes here presented are of the modifications introduced in the application of WKB method.Theproblems of two-and three-dimensional harmonic oscillator potential are revisited by WKB and the new formulationof quantization rule respectively.It is found that the energy spectrum of the radial harmonic oscillator,which isreproduced exactly by the standard WKB method with the Langer modification,is also reproduced exactly without theLanger modification via the new quantization rule approach.An alternative way to obtain the non-integral Maslov indexfor three-dimensional harmonic oscillator is proposed.