中国先进研究堆中子残余应力谱仪校准 被引量:4
1
作者 刘晓龙 刘蕴韬 +4 位作者 陈东风 高建波 李眉娟 阳林峰 韩松柏 《原子能科学技术》 EI CAS CSCD 北大核心 2016年第8期1486-1490,共5页
为校准中国先进研究堆(CARR)中子残余应力谱仪,获得一维位置灵敏探测器(PSD)的灵敏度系数、位置坐标与衍射角的几何关系及零点等参数,设计了校准实验和软件,并将获得的校准参数用于标准Fe粉前4个衍射峰的数据预处理,校正衍射峰位与计算... 为校准中国先进研究堆(CARR)中子残余应力谱仪,获得一维位置灵敏探测器(PSD)的灵敏度系数、位置坐标与衍射角的几何关系及零点等参数,设计了校准实验和软件,并将获得的校准参数用于标准Fe粉前4个衍射峰的数据预处理,校正衍射峰位与计算衍射角的差值符合残余应力谱仪的误差要求。结果表明,该工作能准确获得校准参数,并可用于CARR中子残余应力谱仪的数据预处理。 展开更多
关键词 中子残余应力 一维位置灵敏探测器 谱仪校准
下载PDF
On joint analysing XMM-NuSTAR spectra of active galactic nuclei
2
作者 Jialai Kang Junxian Wang 《中国科学技术大学学报》 CAS CSCD 北大核心 2024年第7期19-33,18,I0002,共17页
A recently released XMM-Newton note revealed a significant calibration issue between nuclear spectroscopic telescope array(NuSTAR)and XMM-Newton European Photon Imaging Camera(EPIC)and provided an empirical correction... A recently released XMM-Newton note revealed a significant calibration issue between nuclear spectroscopic telescope array(NuSTAR)and XMM-Newton European Photon Imaging Camera(EPIC)and provided an empirical correction to the EPIC effective area.To quantify the bias caused by the calibration issue in the joint analysis of XMM-NuSTAR spectra and verify the effectiveness of the correction,in this work,we perform joint-fitting of the NuSTAR and EPIC-pn spectra for a large sample of 104 observation pairs of 44 X-ray bright active galactic nuclei(AGN).The spectra were extracted after requiring perfect simultaneity between the XMM-Newton and NuSTAR exposures(merging good time intervals(GTIs)from two missions)to avoid bias due to the rapid spectral variability of the AGN.Before the correction,the EPIC-pn spectra are systematically harder than the corresponding NuSTAR spectra by■subsequently yielding significantly underestimated cutoff energy E_(cut)and the strength of reflection component R when performing joint-fitting.We confirm that the correction is highly effective and can commendably erase the discrepancy in best-fitΓ,E_(cut),and R.We thus urge the community to apply the correction when joint-fitting XMM-NuSTAR spectra,but note that the correction is limited to 3–12 keV and therefore not applicable when the soft X-ray band data are included.Besides,we show that as merging GTIs from two missions would cause severe loss of NuSTAR net exposure time,in many cases,joint-fitting yields no advantage compared with utilizing NuSTAR data alone.Finally,We present a technical note on filtering periods of high background flares for XMM-Newton EPIC-pn exposures in the small window(SW)mode. 展开更多
关键词 active galactic nuclei X-ray spectroscopy XMM-NEWTON NuSTAR cross-calibration issue
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部