The mining of the rules from the electrical load time series data which are collected from the EMS (Energy Management System) is discussed. The data from the EMS are too huge and sophisticated to be understood and use...The mining of the rules from the electrical load time series data which are collected from the EMS (Energy Management System) is discussed. The data from the EMS are too huge and sophisticated to be understood and used by the power system engineer, while useful information is hidden in the electrical load data. The authors discuss the use of fuzzy linguistic summary as data mining method to induce the rules from the electrical load time series. The data preprocessing techniques are also discussed in the paper.展开更多
The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is t...The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG in wind energy conversion systems. The negative sequence stator voltage is derived from the unbalanced three phase stator voltages. The compensated rotor voltage in terms of the derived negative sequence stator voltage and slip which minimizes the negative stator and rotor currents is proposed. The results from the simulation of control system with steady state model and dynamic model of the DFIG show that additional control loop with compensated voltage can significantly reduce torque and reactive power pulsations.展开更多
As the prime motor of dispersed energy system, the high-temperature solid oxide fuel cells (SOFC) are high efficient with large heat recovery. This study presents a simulation of SOFC building-based cooling, heat and ...As the prime motor of dispersed energy system, the high-temperature solid oxide fuel cells (SOFC) are high efficient with large heat recovery. This study presents a simulation of SOFC building-based cooling, heat and power (BCHP) system, which can meet basic requirements in power and heating (cooling) of the designated customers. The peak power load can be met by power grid, while the peak heating (cooling) load requirement can be met by backup equipments. In order to solve the economic dispatch problem of the energy system, a restricted nonlinear optimization model has been developed. The production costs can be minimized via both the equality constraints of customer’s heat and power demands, and other inequality constrains of equipments’ capacities. The sequential quadratic programming method has been used to search the solution. The study indicates that the model can be used to optimize the system’s capacities and run strategy. An office building case has been computed, and it is indicated that the model can be served in design and optimization of SOFC-BCHP system.展开更多
文摘The mining of the rules from the electrical load time series data which are collected from the EMS (Energy Management System) is discussed. The data from the EMS are too huge and sophisticated to be understood and used by the power system engineer, while useful information is hidden in the electrical load data. The authors discuss the use of fuzzy linguistic summary as data mining method to induce the rules from the electrical load time series. The data preprocessing techniques are also discussed in the paper.
文摘The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG in wind energy conversion systems. The negative sequence stator voltage is derived from the unbalanced three phase stator voltages. The compensated rotor voltage in terms of the derived negative sequence stator voltage and slip which minimizes the negative stator and rotor currents is proposed. The results from the simulation of control system with steady state model and dynamic model of the DFIG show that additional control loop with compensated voltage can significantly reduce torque and reactive power pulsations.
文摘As the prime motor of dispersed energy system, the high-temperature solid oxide fuel cells (SOFC) are high efficient with large heat recovery. This study presents a simulation of SOFC building-based cooling, heat and power (BCHP) system, which can meet basic requirements in power and heating (cooling) of the designated customers. The peak power load can be met by power grid, while the peak heating (cooling) load requirement can be met by backup equipments. In order to solve the economic dispatch problem of the energy system, a restricted nonlinear optimization model has been developed. The production costs can be minimized via both the equality constraints of customer’s heat and power demands, and other inequality constrains of equipments’ capacities. The sequential quadratic programming method has been used to search the solution. The study indicates that the model can be used to optimize the system’s capacities and run strategy. An office building case has been computed, and it is indicated that the model can be served in design and optimization of SOFC-BCHP system.