考虑负荷弹性空间的配电网可靠性扩展规划方法 被引量:11
1
作者 王梓旭 林伟 +1 位作者 杨知方 余娟 《中国电机工程学报》 EI CSCD 北大核心 2022年第18期6655-6667,共13页
现有配电网可靠性扩展规划通常通过新建变压器、线路等设备提升供电可靠性水平,忽略了负荷弹性调整对可靠性的影响。电力用户可通过投建储能设备,实现负荷需求弹性化,提升供电可靠性水平,减少配电网变压器、线路等昂贵设备投资。文中提... 现有配电网可靠性扩展规划通常通过新建变压器、线路等设备提升供电可靠性水平,忽略了负荷弹性调整对可靠性的影响。电力用户可通过投建储能设备,实现负荷需求弹性化,提升供电可靠性水平,减少配电网变压器、线路等昂贵设备投资。文中提出基于多参数规划理论的负荷弹性空间刻画方法。所提方法考虑用户储能设备投资决策,以配电网所需供给负荷为耦合变量,研究满足用户用电需求的负荷弹性空间,并将用户投资决策成本表示为负荷弹性空间上的分段解析映射函数,反映用户投资决策对可靠性的影响。进一步,为缓解多时段高维负荷弹性空间的计算量爆炸问题,提出基于负荷波动特征解耦策略的负荷弹性空间快速刻画方法。最后,基于凸松弛技术和big-M法,提出考虑负荷弹性空间的配电网可靠性扩展规划线性模型,提升供电可靠性水平。基于24节点配电网测试系统,验证所提方法的有效性和准确性。 展开更多
关键词 配电网扩展规划 可靠性 负荷弹性空间 多参数规划理论
下载PDF
Identifying boundary between near field and far field in ground vibration caused by surface loading 被引量:3
2
作者 高广运 宋健 杨峻 《Journal of Central South University》 SCIE EI CAS 2014年第8期3284-3294,共11页
The boundary between the near and far fields is generally defined as the distance from the vibration source beyond which ground vibrations are mainly dominated by Rayleigh waves. It is closely related to the type of v... The boundary between the near and far fields is generally defined as the distance from the vibration source beyond which ground vibrations are mainly dominated by Rayleigh waves. It is closely related to the type of vibration source and the soil properties. Based on the solutions of the Lamb's problem, the boundary at the surface between the near and far fields of ground vibration was investigated for a harmonic vertical concentrated load and an infinite line load at the surface of a visco-elastic half-space. Particularly, the variation of the boundary with the material damping was investigated for both cases. The results indicate that the material damping slightly contributes to the attenuation of vibrations in the near-source region, but significantly reduces the vibrations in the region that is at some distance away from the source. When taking the material damping into consideration, the boundary between the near and far fields tends to move towards the vibration source. Compared with the vibrations caused by a concentrated load, the vibrations induced by an infinite line load can affect a larger range of the surrounding environment, and they attenuate more slowly. This means the boundary between the near field and far field should move fitrther away from the source. Finally, the boundaries are defined in terms of R-wave length (2R) and Poisson ratio of the ground (o). For the case of a point load, the boundary is located at the distance of (5.0-6.0)2R for v≤0.30 and at the distance of (2.0--3.0)2R for v≥0.35. For the case of an infinite line load, the boundary is located at the distance (5.5-6.5)2rt for v≤0.30 and at the distance (2.5--3.5)2R for v≥0.35. 展开更多
关键词 BOUNDARY near field far field active isolation passive isolation visco-elastic half-space concentrated load line distributed load
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部