Based on experimental data, the energy storage performances of floor radiant heating system were investigated. The decrease of indoor air temperature after the stopping of floor heating was compared with that of fan-c...Based on experimental data, the energy storage performances of floor radiant heating system were investigated. The decrease of indoor air temperature after the stopping of floor heating was compared with that of fan-coil heating system. The increase of indoor air temperature after the stopping of floor cooling system was analyzed. The results show that the floor heating system has good thermal storage performance, which can be used to a night-running model to obtain the energy-saving benefits efficient and economic running cost, and still can be used for “shifting peak load to off-peak” macroscopically.展开更多
The RTQ-C (Technical Requirements of Quality for the Energy Performance Level of Commercial Buildings) publication classified the buildings in five efficiency levels. In RTQ-C, the evaluation can be done with two me...The RTQ-C (Technical Requirements of Quality for the Energy Performance Level of Commercial Buildings) publication classified the buildings in five efficiency levels. In RTQ-C, the evaluation can be done with two methods: a prescriptive method and a simulation one. This paper aims to identify the sensibility of the prescriptive method RTQ-C regarding the variation of equipment internal load density in office buildings in bioclimatic Zones I and 7 of the Brazilian bioclimatic zoning. The research results show that the building with walls and roof configured to meet specific prerequisites for energy efficiency Levels B and C had a lower consumption than buildings that meet the prerequisites to Level A. The study also showed that buildings with high internal load density of equipment, maximum shape factor and high, with walls and roofs with higher thermal transmittance, have lower power consumption than constructions with an envelope with greater thermal resistance. The increase in internal load density causes an increase in the internal heat generated by the large amount of equipment. In buildings with higher thermal insulation (Level A), the internal heat is maintained in the environment, causing overheating and the need for an air conditioning system.展开更多
A concept of energy saving & efficiency improving from cold source for cogeneration steam turbine was discussed herein. A new type "NCB" cogeneration steam turbine was proposed,which could considerably i...A concept of energy saving & efficiency improving from cold source for cogeneration steam turbine was discussed herein. A new type "NCB" cogeneration steam turbine was proposed,which could considerably increase heat supply capacity,thermal efficiency and electric power. Taking 300 MW cogeneration steam turbine as an example,the results show that heat supply capacity reaches the maximum,i.e. increases by 30 %,thermal efficiency is improved by 12 %,and electric power is enhanced by 15 MW during peak heat load.展开更多
文摘Based on experimental data, the energy storage performances of floor radiant heating system were investigated. The decrease of indoor air temperature after the stopping of floor heating was compared with that of fan-coil heating system. The increase of indoor air temperature after the stopping of floor cooling system was analyzed. The results show that the floor heating system has good thermal storage performance, which can be used to a night-running model to obtain the energy-saving benefits efficient and economic running cost, and still can be used for “shifting peak load to off-peak” macroscopically.
文摘The RTQ-C (Technical Requirements of Quality for the Energy Performance Level of Commercial Buildings) publication classified the buildings in five efficiency levels. In RTQ-C, the evaluation can be done with two methods: a prescriptive method and a simulation one. This paper aims to identify the sensibility of the prescriptive method RTQ-C regarding the variation of equipment internal load density in office buildings in bioclimatic Zones I and 7 of the Brazilian bioclimatic zoning. The research results show that the building with walls and roof configured to meet specific prerequisites for energy efficiency Levels B and C had a lower consumption than buildings that meet the prerequisites to Level A. The study also showed that buildings with high internal load density of equipment, maximum shape factor and high, with walls and roofs with higher thermal transmittance, have lower power consumption than constructions with an envelope with greater thermal resistance. The increase in internal load density causes an increase in the internal heat generated by the large amount of equipment. In buildings with higher thermal insulation (Level A), the internal heat is maintained in the environment, causing overheating and the need for an air conditioning system.
文摘A concept of energy saving & efficiency improving from cold source for cogeneration steam turbine was discussed herein. A new type "NCB" cogeneration steam turbine was proposed,which could considerably increase heat supply capacity,thermal efficiency and electric power. Taking 300 MW cogeneration steam turbine as an example,the results show that heat supply capacity reaches the maximum,i.e. increases by 30 %,thermal efficiency is improved by 12 %,and electric power is enhanced by 15 MW during peak heat load.