We take the contribution of all valence electrons into consideration and propose a new valence electrons equilibration method to calculate the equalized electronegativity including molecular electronegativity, group e...We take the contribution of all valence electrons into consideration and propose a new valence electrons equilibration method to calculate the equalized electronegativity including molecular electronegativity, group electronegativity, and atomic charge. The ionization potential of alkanes and mono-substituted alkanes, the chemical shift of 1H NMR, and the gas phase proton affinity of aliphatic amines, alcohols, and ethers were estimated. All the expressions have good correlations. Moreover, the Sanderson method and Bratsch method were modified on the basis of the valence electrons equilibration theory. The modified Sanderson method and modified Bratsch method are more effective than their original methods to estimate these properties.展开更多
Voltage profiles of feeders with the connection of distributed generations(DGs) were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profi...Voltage profiles of feeders with the connection of distributed generations(DGs) were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profile with single and double DGs were derived and used to analyze the impact of DG's location and capacity on the voltage profile quantitatively.Then,a general formula of the voltage profile was derived.The limitation of single DG and necessity of multiple DGs for voltage regulation were also discussed.Through the simulation,voltage profiles of feeders with single and double DGs were compared.The voltage excursion rate is 7.40% for only one DG,while 2.48% and 2.36% for double DGs.It is shown that the feeder voltage can be retained in a more appropriate range with multiple DGs than with only one DG.Distributing the total capacity of DGs is better than concentrating it at one point.展开更多
The existing hydraulic system always have problems of temperature rise,runningstability and anti-interference of the implementation components,reliability of hydrauliccomponents,maintenance difficulties,and other issu...The existing hydraulic system always have problems of temperature rise,runningstability and anti-interference of the implementation components,reliability of hydrauliccomponents,maintenance difficulties,and other issues.With high efficiency,energysaving,reliability,easy operating,stable running,anti-interference ability,and other advantages,the load-sensitive hydraulic system is more suitable for coal mine all-hydrauliccore rig.Therefore,for the technical development of the coal mine all-hydraulic core rig,the load-sensitive technology employed by the rig should be of great significance.展开更多
1 INTRODUCTIONThe determination of the solids hold-up and local solidfluxes is of paramount importance in the study ofthe hydrodynamics of a two-phase flow.Several tech-niques have been used during the past decades(Ta...1 INTRODUCTIONThe determination of the solids hold-up and local solidfluxes is of paramount importance in the study ofthe hydrodynamics of a two-phase flow.Several tech-niques have been used during the past decades(Table1).These methods can be classified in two groups,depending on their possible disturbance of the two-展开更多
In order to control the locomotive wheel(axle) load distribution, a shimming process to adjust the locomotive secondary spring loads was heretofore developed. An immune dominance clonal selection multi-objective algor...In order to control the locomotive wheel(axle) load distribution, a shimming process to adjust the locomotive secondary spring loads was heretofore developed. An immune dominance clonal selection multi-objective algorithm based on the artificial immune system was presented to further improve the performance of the optimization algorithm for locomotive secondary spring load adjustment, especially to solve the lack of control on the output shim quantity. The algorithm was designed into a two-level optimization structure according to the preferences of the problem, and the priori knowledge of the problem was used as the immune dominance. Experiments on various types of locomotives show that owing to the novel algorithm, the shim quantity is cut down by 30% 60% and the calculation time is about 90% less while the secondary spring load distribution is controlled on the same level as before. The application of this optimization algorithm can significantly improve the availability and efficiency of the secondary spring adjustment process.展开更多
Non-point-source pollution has become a major threat to the water quality of the Three Gorges Reservoir(TGR);however,nutrient loadings from terrestrial sources are unclear due to a lack of in situ monitoring.A represe...Non-point-source pollution has become a major threat to the water quality of the Three Gorges Reservoir(TGR);however,nutrient loadings from terrestrial sources are unclear due to a lack of in situ monitoring.A representative small watershed in the central part of the TGR area was selected to monitor the loss of nitrogen(N) and phosphorous(P) continuously along with the runoff from 2007 through 2009 to understand the exact sources and loadings.Results show that the non-point-source nitrogen and phosphorus comes mainly from the storm runoff from residential areas,citrus orchards and sloping croplands,which contributes up to 76% of the loadings in this watershed.Thus,a crucial measure for controlling non-point-source pollution is to intercept storm runoff from the three sources.Paddy fields provide a sink for non-point-source N and P by intercepting the runoff and sediment along with their different forms of nitrogen and phosphorus.The N and P removal efficiency by paddy fields from residential areas is within the range of 56% to 98%.Paddy fields are an important land-use option for reducing the non-point-source loading of N and P in the TGR area.展开更多
According to the interaction of three shallow tunnels with large section, the analytical solution to rock pressure has been derived and discussed. The load model is given when the bilateral tunnels are excavated. Acco...According to the interaction of three shallow tunnels with large section, the analytical solution to rock pressure has been derived and discussed. The load model is given when the bilateral tunnels are excavated. According to the model, the stresses of three tunnels and single tunnel are calculated and compared to analyze the distribution characteristics, where the stresses are influenced by controlling factors of clear distance, covering depth and inclination angle of ground surface. The results show that, in general, the bias distribution is more serious. Therefore, it is significant to settle down the load model of three shallow tunnels so as to determine the measure of reinforcement and design the structure of support. The model and results can be used as a theoretical basis in designation and further research of the three shallow tunnels.展开更多
A multivariable regression(MVR) approach is proposed to identify the real power transfer between generators and loads.Based on solved load flow results,it first uses modified nodal equation method(MNE) to determine re...A multivariable regression(MVR) approach is proposed to identify the real power transfer between generators and loads.Based on solved load flow results,it first uses modified nodal equation method(MNE) to determine real power contribution from each generator to loads.Then,the results of MNE method and load flow information are utilized to determine suitable regression coefficients using MVR model to estimate the power transfer.The 25-bus equivalent system of south Malaysia is utilized as a test system to illustrate the effectiveness of the MVR output compared to that of the MNE method.The error of the estimate of MVR method ranges from 0.001 4 to 0.007 9.Furthermore,when compared to MNE method,MVR method computes generator contribution to loads within 26.40 ms whereas the MNE method takes 360 ms for the calculation of same real power transfer allocation.Therefore,MVR method is more suitable for real time power transfer allocation.展开更多
A bottoming cycle system based on CO2 Brayton cycle is proposed to recover the engine exhaust heat. Its performance is compared with the conventional air Brayton cycle under five typical engine conditions. The results...A bottoming cycle system based on CO2 Brayton cycle is proposed to recover the engine exhaust heat. Its performance is compared with the conventional air Brayton cycle under five typical engine conditions. The results show that CO2 Brayton cycle proves to be superior to the air Brayton cycle in terms of the system net output power, thermal efficiency and recovery efficiency. In most cases, the recovery efficiency of CO2 Brayton cycle can be higher than 9% and the system has a better performance at the engine's high operating load, The thermal efficiency can be as large as 24.83% under 100% olaerating load, accordingly, the net outnut nower of 14.86 kW in nhtnined展开更多
The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, t...The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, the graph fitting technique is applied with some mathematical and computational tools based on the actual values of the years 2009 up to 2012 considering the lower values, the higher values and the average values of the annual maximum loads for Kingdom of Bahrain. For the three scenarios, the models are obtained by curve fitting technique. As well, the model of actual loads is obtained finally which has mostly the closest values obtained.展开更多
ELD (economic load dispatch) problem is one of the essential issues in power system operation. The objective of solving ELD problem is to allocate the generation output of the committed generating units. The main co...ELD (economic load dispatch) problem is one of the essential issues in power system operation. The objective of solving ELD problem is to allocate the generation output of the committed generating units. The main contribution of this work is to solve the ELD problem concerned with daily load pattern. The proposed solution technique, developed based PSO (particle swarm optimization) algorithm, is applied to search for the optimal schedule of all generations units that can supply the required load demand at minimum fuel cost while satisfying all unit and system operational constraints. The performance of the developed methodology is demonstrated by case studies in test system of six-generation units. The results obtained from the PSO are compared to those achieved from other approaches, such as QP (quadratic programming), and GA (genetic algorithm).展开更多
The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load...The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.展开更多
Minimax probability machine regression (MPMR) was proposed for chaotic load time series global prediction. In MPMR, regression function maximizes the minimum probability that future predication will be within an ε ...Minimax probability machine regression (MPMR) was proposed for chaotic load time series global prediction. In MPMR, regression function maximizes the minimum probability that future predication will be within an ε to the true regression function. After exploring the principle of MPMR, and verifying the chaotic property of the load series from a certain power system, one-day-ahead predictions for 24 time points next day wcre done with MPMR. Thc results demonstrate that MPMP has satisfactory prediction efficiency. Kernel function shape parameter and regression tube value may influence the MPMR-based system performance. In the experiments, cross validation was used to choose the two parameters.展开更多
Corbels support the crossbeams of half-through arch bridges. They are prone to cracking easily due to their characteristics and complicated loading conditions. Based on a practical diagnosis of a bridge crossbeam, we ...Corbels support the crossbeams of half-through arch bridges. They are prone to cracking easily due to their characteristics and complicated loading conditions. Based on a practical diagnosis of a bridge crossbeam, we bonded steel plates onto bridge corbels to strengthen them. We carried out a numerical analysis on the effectiveness of the reinforcement by using the commercial sof^are ANSYS. The numerical analysis shows that the stresses near the section break increased slightly, but the variation amplitude was small and all the stresses were within an allowable range. The loading test indicates that it is feasible to strengthen the corbel with vertical bonded steel plates. Therefore, the reinforcement is effective and economical. This reinforcement method is suitable for this type of corbel and can be applied in similar cases.展开更多
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads...A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads.展开更多
3 GPP LTE has approved uplink intra-cell power control and defined overload indicator (OI) for uplink inter-cell power contrQ1 to mitigate the inter-cell interference (ICI), respectively. In this pa- per, we propo...3 GPP LTE has approved uplink intra-cell power control and defined overload indicator (OI) for uplink inter-cell power contrQ1 to mitigate the inter-cell interference (ICI), respectively. In this pa- per, we propose a hierarchical power control ( HPC ) scheme where intra-eell and inter-cell power controls interact with each other. The inter-cell power control eommand is generated by radio re- source management (RRM) entity according to the ICI-load model together with the current ICI and served load information. This ICI-load model is proposed as a guideline for coordination among cells to enable the system to approach its system specific interference over thermal noise (IoT) work area. Simulation results show that for HPC scheme, the system' s IoT is well controlled to fit its pre-de- fined work area and the power efficiency is improved significantly. Our proposed scheme is also ro- bust to different settings of its inter-cell power control period.展开更多
The water level rising rate of Tangshan mine well significantly accelerated in 2010,and the ascensional range was obviously higher than that of the same period in previous years.From the view of groundwater dynamics a...The water level rising rate of Tangshan mine well significantly accelerated in 2010,and the ascensional range was obviously higher than that of the same period in previous years.From the view of groundwater dynamics and loading effects,and based on the water pumping( pouring) water test model and semi-infinite elastic space theory model under uniform load,the effects of grouting and loading of nearby building construction on the well water level were analyzed. Results show that grouting at a distance of 200 ~ 700 m to the well,with amount of 2500m3 per day and duration of 270 d,can cause an 8 ~ 11 m rise of well water level; and loading of large-area building construction can cause about a 4m rise of well water level. Through the analysis of these factors,we find that the water level anomalous rising of Tangshan mine well was relevant to grouting and loading of the nearby building construction. This study provides a scientific basis for anomalous rising analysis of water level of Tangshan mine well.展开更多
文摘We take the contribution of all valence electrons into consideration and propose a new valence electrons equilibration method to calculate the equalized electronegativity including molecular electronegativity, group electronegativity, and atomic charge. The ionization potential of alkanes and mono-substituted alkanes, the chemical shift of 1H NMR, and the gas phase proton affinity of aliphatic amines, alcohols, and ethers were estimated. All the expressions have good correlations. Moreover, the Sanderson method and Bratsch method were modified on the basis of the valence electrons equilibration theory. The modified Sanderson method and modified Bratsch method are more effective than their original methods to estimate these properties.
基金Projects(60904101,60972164) supported by the National Natural Science Foundation of ChinaProject(N090404009) supported by the Fundamental Research Funds for the Central UniversitiesProject(20090461187) supported by China Postdoctoral Science Foundation
文摘Voltage profiles of feeders with the connection of distributed generations(DGs) were investigated.A unified typical load distribution model was established.Based on this model,exact expressions of feeder voltage profile with single and double DGs were derived and used to analyze the impact of DG's location and capacity on the voltage profile quantitatively.Then,a general formula of the voltage profile was derived.The limitation of single DG and necessity of multiple DGs for voltage regulation were also discussed.Through the simulation,voltage profiles of feeders with single and double DGs were compared.The voltage excursion rate is 7.40% for only one DG,while 2.48% and 2.36% for double DGs.It is shown that the feeder voltage can be retained in a more appropriate range with multiple DGs than with only one DG.Distributing the total capacity of DGs is better than concentrating it at one point.
基金Supported by the Youth Innovation Fund of China Coal Research Institute(2007QN50)
文摘The existing hydraulic system always have problems of temperature rise,runningstability and anti-interference of the implementation components,reliability of hydrauliccomponents,maintenance difficulties,and other issues.With high efficiency,energysaving,reliability,easy operating,stable running,anti-interference ability,and other advantages,the load-sensitive hydraulic system is more suitable for coal mine all-hydrauliccore rig.Therefore,for the technical development of the coal mine all-hydraulic core rig,the load-sensitive technology employed by the rig should be of great significance.
文摘1 INTRODUCTIONThe determination of the solids hold-up and local solidfluxes is of paramount importance in the study ofthe hydrodynamics of a two-phase flow.Several tech-niques have been used during the past decades(Table1).These methods can be classified in two groups,depending on their possible disturbance of the two-
基金Project(51305467)supported by the National Natural Science Foundation of ChinaProject(12JJ4050)supported by the Natural Science Foundation of Hunan Province,China
文摘In order to control the locomotive wheel(axle) load distribution, a shimming process to adjust the locomotive secondary spring loads was heretofore developed. An immune dominance clonal selection multi-objective algorithm based on the artificial immune system was presented to further improve the performance of the optimization algorithm for locomotive secondary spring load adjustment, especially to solve the lack of control on the output shim quantity. The algorithm was designed into a two-level optimization structure according to the preferences of the problem, and the priori knowledge of the problem was used as the immune dominance. Experiments on various types of locomotives show that owing to the novel algorithm, the shim quantity is cut down by 30% 60% and the calculation time is about 90% less while the secondary spring load distribution is controlled on the same level as before. The application of this optimization algorithm can significantly improve the availability and efficiency of the secondary spring adjustment process.
基金supported by the National Science & Technology Pillar Program(Grant No. 2011BAD31B03)the Special Project on Water Pollution Control by the National Science & Technology Pillar Program(Grant No. 2009ZX07104-002)
文摘Non-point-source pollution has become a major threat to the water quality of the Three Gorges Reservoir(TGR);however,nutrient loadings from terrestrial sources are unclear due to a lack of in situ monitoring.A representative small watershed in the central part of the TGR area was selected to monitor the loss of nitrogen(N) and phosphorous(P) continuously along with the runoff from 2007 through 2009 to understand the exact sources and loadings.Results show that the non-point-source nitrogen and phosphorus comes mainly from the storm runoff from residential areas,citrus orchards and sloping croplands,which contributes up to 76% of the loadings in this watershed.Thus,a crucial measure for controlling non-point-source pollution is to intercept storm runoff from the three sources.Paddy fields provide a sink for non-point-source N and P by intercepting the runoff and sediment along with their different forms of nitrogen and phosphorus.The N and P removal efficiency by paddy fields from residential areas is within the range of 56% to 98%.Paddy fields are an important land-use option for reducing the non-point-source loading of N and P in the TGR area.
基金Projects(2013CB036004, 2011CB013800) supported by the National Basic Research Program of ChinaProject(51178468, 50908234) supported by the National Natural Science Foundation of ChinaProject(2011G103-B) supported by the Science and Technology Development of Railway in China
文摘According to the interaction of three shallow tunnels with large section, the analytical solution to rock pressure has been derived and discussed. The load model is given when the bilateral tunnels are excavated. According to the model, the stresses of three tunnels and single tunnel are calculated and compared to analyze the distribution characteristics, where the stresses are influenced by controlling factors of clear distance, covering depth and inclination angle of ground surface. The results show that, in general, the bias distribution is more serious. Therefore, it is significant to settle down the load model of three shallow tunnels so as to determine the measure of reinforcement and design the structure of support. The model and results can be used as a theoretical basis in designation and further research of the three shallow tunnels.
文摘A multivariable regression(MVR) approach is proposed to identify the real power transfer between generators and loads.Based on solved load flow results,it first uses modified nodal equation method(MNE) to determine real power contribution from each generator to loads.Then,the results of MNE method and load flow information are utilized to determine suitable regression coefficients using MVR model to estimate the power transfer.The 25-bus equivalent system of south Malaysia is utilized as a test system to illustrate the effectiveness of the MVR output compared to that of the MNE method.The error of the estimate of MVR method ranges from 0.001 4 to 0.007 9.Furthermore,when compared to MNE method,MVR method computes generator contribution to loads within 26.40 ms whereas the MNE method takes 360 ms for the calculation of same real power transfer allocation.Therefore,MVR method is more suitable for real time power transfer allocation.
基金Supported by the National Basic Research Program of China("973"Program,No.2011CB707201)the National Natural Science Foundation of China(No.51206117)
文摘A bottoming cycle system based on CO2 Brayton cycle is proposed to recover the engine exhaust heat. Its performance is compared with the conventional air Brayton cycle under five typical engine conditions. The results show that CO2 Brayton cycle proves to be superior to the air Brayton cycle in terms of the system net output power, thermal efficiency and recovery efficiency. In most cases, the recovery efficiency of CO2 Brayton cycle can be higher than 9% and the system has a better performance at the engine's high operating load, The thermal efficiency can be as large as 24.83% under 100% olaerating load, accordingly, the net outnut nower of 14.86 kW in nhtnined
文摘The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, the graph fitting technique is applied with some mathematical and computational tools based on the actual values of the years 2009 up to 2012 considering the lower values, the higher values and the average values of the annual maximum loads for Kingdom of Bahrain. For the three scenarios, the models are obtained by curve fitting technique. As well, the model of actual loads is obtained finally which has mostly the closest values obtained.
文摘ELD (economic load dispatch) problem is one of the essential issues in power system operation. The objective of solving ELD problem is to allocate the generation output of the committed generating units. The main contribution of this work is to solve the ELD problem concerned with daily load pattern. The proposed solution technique, developed based PSO (particle swarm optimization) algorithm, is applied to search for the optimal schedule of all generations units that can supply the required load demand at minimum fuel cost while satisfying all unit and system operational constraints. The performance of the developed methodology is demonstrated by case studies in test system of six-generation units. The results obtained from the PSO are compared to those achieved from other approaches, such as QP (quadratic programming), and GA (genetic algorithm).
文摘The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.
基金The research was supported by the Science & Research Foundation of East China Jiaotong University (No.23)
文摘Minimax probability machine regression (MPMR) was proposed for chaotic load time series global prediction. In MPMR, regression function maximizes the minimum probability that future predication will be within an ε to the true regression function. After exploring the principle of MPMR, and verifying the chaotic property of the load series from a certain power system, one-day-ahead predictions for 24 time points next day wcre done with MPMR. Thc results demonstrate that MPMP has satisfactory prediction efficiency. Kernel function shape parameter and regression tube value may influence the MPMR-based system performance. In the experiments, cross validation was used to choose the two parameters.
文摘Corbels support the crossbeams of half-through arch bridges. They are prone to cracking easily due to their characteristics and complicated loading conditions. Based on a practical diagnosis of a bridge crossbeam, we bonded steel plates onto bridge corbels to strengthen them. We carried out a numerical analysis on the effectiveness of the reinforcement by using the commercial sof^are ANSYS. The numerical analysis shows that the stresses near the section break increased slightly, but the variation amplitude was small and all the stresses were within an allowable range. The loading test indicates that it is feasible to strengthen the corbel with vertical bonded steel plates. Therefore, the reinforcement is effective and economical. This reinforcement method is suitable for this type of corbel and can be applied in similar cases.
基金This project is financed by the New Century Outstanding Talents Supporting Program of Ministry of Education and Superior Young Teachers Supporting Program of Ministry of Education.
文摘A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads.
基金Supported by the National High Technology Research and Development Programme of China(No.2009AA011501)International S&T Cooperation Program of Shanghai Municipality(No.09530702500&10220712100)Major Project of Shanghai Municipality(No.09511501100)
文摘3 GPP LTE has approved uplink intra-cell power control and defined overload indicator (OI) for uplink inter-cell power contrQ1 to mitigate the inter-cell interference (ICI), respectively. In this pa- per, we propose a hierarchical power control ( HPC ) scheme where intra-eell and inter-cell power controls interact with each other. The inter-cell power control eommand is generated by radio re- source management (RRM) entity according to the ICI-load model together with the current ICI and served load information. This ICI-load model is proposed as a guideline for coordination among cells to enable the system to approach its system specific interference over thermal noise (IoT) work area. Simulation results show that for HPC scheme, the system' s IoT is well controlled to fit its pre-de- fined work area and the power efficiency is improved significantly. Our proposed scheme is also ro- bust to different settings of its inter-cell power control period.
基金funded by the Earthquake Tracking Contract Orientated Task,CEA(2011020303)Science and Technology Project of Hebei Province(13275407D)
文摘The water level rising rate of Tangshan mine well significantly accelerated in 2010,and the ascensional range was obviously higher than that of the same period in previous years.From the view of groundwater dynamics and loading effects,and based on the water pumping( pouring) water test model and semi-infinite elastic space theory model under uniform load,the effects of grouting and loading of nearby building construction on the well water level were analyzed. Results show that grouting at a distance of 200 ~ 700 m to the well,with amount of 2500m3 per day and duration of 270 d,can cause an 8 ~ 11 m rise of well water level; and loading of large-area building construction can cause about a 4m rise of well water level. Through the analysis of these factors,we find that the water level anomalous rising of Tangshan mine well was relevant to grouting and loading of the nearby building construction. This study provides a scientific basis for anomalous rising analysis of water level of Tangshan mine well.