Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is...Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.展开更多
Background To report quality control methods and baseline reproducibility data of the ultrasound measurements of carotid artery intima-media thickness in the project of Establishment of an Integrated System for Corona...Background To report quality control methods and baseline reproducibility data of the ultrasound measurements of carotid artery intima-media thickness in the project of Establishment of an Integrated System for Coronary Heart Disease Prevention and Treatment. Methods Standard ultrasound scanning and measuring protocols were established by the study group. All sonographers and readers were trained by the carotid ultrasound core lab and all digital ultrasound images were centrally read. Ten subjects were scanned twice (with 1 week interval) by 2 sonographers independently and images were read by a single reader to evaluate the sonographer variability. Twenty subjects' images were read twice (with 1 week interval) by a single reader to assess the reader variability and the reproducibility of IMT measured at different carotid segments. Results The intraclass correlation (ICC) of intra- and inter-sonographer and intra- reader for mean IMT measurements was 0.99, 0.98 and 0.97 respectively; while for max IMT, it was 0.97, 0.99 and 0.95 respectively. Among different carotid segments and sites, ICC for mean 1MT measurements of common carotid (CCA), carotid artery bulb (Bulb), internal carotid artery (ICA), overall near wall and overall far wall was 0.97, 0.99, 0.89, 0.93 and 0.98 respectively. Conclusion The reproducibility of IMT measurements according to our protocol is acceptable, although better reproducibility is found when measuring the mean IMT than max IMT, CCA and Bulb IMT than ICA IMT, and far wall IMT than near wall IMT.展开更多
The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of...The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of coarse sand,fine sand and silty clay in different water contents. The results that measured by the probe method are well consistent with those of QTM-D_2. The soil thermal conductivity increases in different levels with the increase of the water content. Compared the soil thermal conductivity measured by the probe method in laboratory with in-situ experiment,it shows that the measuring gap gradually increases with the increase of the depth. The reason is that the in-situ measuring thermal conductivity can reflect the actual situation of the soil mass.展开更多
Accurate assessment of herbage mass (HM) in pasture is a key to budgeting forage in grazing systems worldwide. Different non-destructive techniques to measuring pasture yield are commented. The methods compared incl...Accurate assessment of herbage mass (HM) in pasture is a key to budgeting forage in grazing systems worldwide. Different non-destructive techniques to measuring pasture yield are commented. The methods compared include visual estimations, manual and electronic pasture meters and remote sensing. All methods are associated with a moderate to high error, showing that some indirect methods of yield estimation are appropriate under most appropriate because many factors as climate variations, soil certain conditions. In general terms, no method was found as the characteristics, plant phenology, pasture management and species composition must be taken into account to make local calibrations from a general model. Best results were found modifying general methods under local calibrations and under local conditions. In order to give farmers the best method to manage adequately their own grazing systems, researchers must select the most suitable technique considering the scale of operation, the desired accuracy and the resources available.展开更多
The Quality factor is the parameter that can be used to describe the energy attenuation on seismic wave. In theory, we can obtain the relationship between the change of the coda wave quality factor with time and the s...The Quality factor is the parameter that can be used to describe the energy attenuation on seismic wave. In theory, we can obtain the relationship between the change of the coda wave quality factor with time and the strong earthquake preparation process on the basis of the quality factor of a coda wave in a same ray path. However, in reality the coda wave quality factor measured by different seismic coda waves corresponds to different seismic wave ray paths. The change of the quality factor with time is related to non-elastic characteristics of the medium and the volume of scattering ellipsoid constrained by scattered wave phase fronts, besides the change of regional stress field. This paper discusses the relationship between quality factor, epicenter distance and different lapse time, and then discusses the relationship between quality factor and frequency. Furthermore the determination method of the coda wave quality factor is put forward. The improved determination method of the quality factor, which removes the influence of different earthquakes or propagation depth of scattered waves, may increase measurement precision, thus information pertaining to abnormal changes in quality factor and the relationship between the quality factor and earthquake preparation process can be acquired.展开更多
The conventional quality control method of core rocldill dam construction exhibit difficulty controlling compaction parameters accurately or ensuring construction quality. This is because it is easily influenced by hu...The conventional quality control method of core rocldill dam construction exhibit difficulty controlling compaction parameters accurately or ensuring construction quality. This is because it is easily influenced by human behavior or lack of adequate management. We therefore establish the timely monitoring indexes and control criteria of compaction processes by considering the characteristics and quality requirements of high core rockffll dam construction. Based on the established indexes and criteria, integrating GPS, GPRS and PDA technologies, a real-time compaction quality monitoring method is proposed. The relevant key techniques are proposed as well, including automatic collection of information and a graphic algorithm for rolling-process visualization. By the proposed method and techniques, a real-time monitoring system is provided to realize the precise automatic online entire-process monitoring of compaction parameters, including compaction pass, rolling trajectory, nmning speed of roller, vibration status and rolled pavement thickness. The application of the Nuozhadu project shows that the proposed system can control compaction parameters effectively and ensure better construction quality. Therefore, it might become a new way towards construction quality control of high core rockfill dam.展开更多
Astronaut's body mass is an essential factor of health monitoring in space.The latest mass measurement device for the International Space Station (ISS) has employed a linear acceleration method.The principle of th...Astronaut's body mass is an essential factor of health monitoring in space.The latest mass measurement device for the International Space Station (ISS) has employed a linear acceleration method.The principle of this method is that the device generates a constant pulling force,and the astronaut is accelerated on a parallelogram motion guide which rotates at a large radius to achieve a nearly linear trajectory.The acceleration is calculated by regression analysis of the displacement versus time trajectory and the body mass is calculated by using the formula m=F/a.However,in actual flight,the device is instable that the deviation between runs could be 6-7 kg.This paper considers the body non-rigidity as the major cause of error and instability and analyzes the effects of body non-rigidity from different aspects.Body non-rigidity makes the acceleration of the center of mass (C.M.) oscillate and fall behind the point where force is applied.Actual acceleration curves showed that the overall effect of body non-rigidity is an oscillation at about 7 Hz and a deviation of about 25%.To enhance body rigidity,better body restraints were introduced and a prototype based on linear acceleration method was built.Measurement experiment was carried out on ground on an air table.Three human subjects weighing 60-70 kg were measured.The average variance was 0.04 kg and the average measurement error was 0.4%.This study will provide reference for future development of China's own mass measurement device.展开更多
A temperature measurement model of radiation thermometry for the surface covered by participating media was developed. The model was based on the radiation heat transfer of participating media and principles of radiat...A temperature measurement model of radiation thermometry for the surface covered by participating media was developed. The model was based on the radiation heat transfer of participating media and principles of radiation pyrometers, and solved by integral formulation of discrete ordinate method on spectral waveband. The influence of water mist on the indicated temperature of Raytek MR1SB one/two color pyrometer was discussed. Mie theory was used to calculate the radiative properties of water mist. In order to verify the model, a laboratory temperature measurement experiment was executed. The result shows that temperature of radiation thermometry is sensitive to the spectral response wavelength of pyrometer, and the simulated temperature of pyrometer agrees well with the experimental measurements on a suitable wavelength. The simulated temperature was lower than the real temperature of surface for one-color pyrometer, and it could be higher or lower than the real one for two-color pyrometer with the influence of participating media.展开更多
文摘Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.
文摘Background To report quality control methods and baseline reproducibility data of the ultrasound measurements of carotid artery intima-media thickness in the project of Establishment of an Integrated System for Coronary Heart Disease Prevention and Treatment. Methods Standard ultrasound scanning and measuring protocols were established by the study group. All sonographers and readers were trained by the carotid ultrasound core lab and all digital ultrasound images were centrally read. Ten subjects were scanned twice (with 1 week interval) by 2 sonographers independently and images were read by a single reader to evaluate the sonographer variability. Twenty subjects' images were read twice (with 1 week interval) by a single reader to assess the reader variability and the reproducibility of IMT measured at different carotid segments. Results The intraclass correlation (ICC) of intra- and inter-sonographer and intra- reader for mean IMT measurements was 0.99, 0.98 and 0.97 respectively; while for max IMT, it was 0.97, 0.99 and 0.95 respectively. Among different carotid segments and sites, ICC for mean 1MT measurements of common carotid (CCA), carotid artery bulb (Bulb), internal carotid artery (ICA), overall near wall and overall far wall was 0.97, 0.99, 0.89, 0.93 and 0.98 respectively. Conclusion The reproducibility of IMT measurements according to our protocol is acceptable, although better reproducibility is found when measuring the mean IMT than max IMT, CCA and Bulb IMT than ICA IMT, and far wall IMT than near wall IMT.
基金Supported by Project of National Natural Science Foundation of China(No.41372239)
文摘The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of coarse sand,fine sand and silty clay in different water contents. The results that measured by the probe method are well consistent with those of QTM-D_2. The soil thermal conductivity increases in different levels with the increase of the water content. Compared the soil thermal conductivity measured by the probe method in laboratory with in-situ experiment,it shows that the measuring gap gradually increases with the increase of the depth. The reason is that the in-situ measuring thermal conductivity can reflect the actual situation of the soil mass.
文摘Accurate assessment of herbage mass (HM) in pasture is a key to budgeting forage in grazing systems worldwide. Different non-destructive techniques to measuring pasture yield are commented. The methods compared include visual estimations, manual and electronic pasture meters and remote sensing. All methods are associated with a moderate to high error, showing that some indirect methods of yield estimation are appropriate under most appropriate because many factors as climate variations, soil certain conditions. In general terms, no method was found as the characteristics, plant phenology, pasture management and species composition must be taken into account to make local calibrations from a general model. Best results were found modifying general methods under local calibrations and under local conditions. In order to give farmers the best method to manage adequately their own grazing systems, researchers must select the most suitable technique considering the scale of operation, the desired accuracy and the resources available.
基金sponsored by the Natural Science Foundation of Shandong Province (Y2007E09)Joint Earthquake Science Foundation (C08028)Special Application Research of Digital Seismic Wave Data ,Shangdong,China
文摘The Quality factor is the parameter that can be used to describe the energy attenuation on seismic wave. In theory, we can obtain the relationship between the change of the coda wave quality factor with time and the strong earthquake preparation process on the basis of the quality factor of a coda wave in a same ray path. However, in reality the coda wave quality factor measured by different seismic coda waves corresponds to different seismic wave ray paths. The change of the quality factor with time is related to non-elastic characteristics of the medium and the volume of scattering ellipsoid constrained by scattered wave phase fronts, besides the change of regional stress field. This paper discusses the relationship between quality factor, epicenter distance and different lapse time, and then discusses the relationship between quality factor and frequency. Furthermore the determination method of the coda wave quality factor is put forward. The improved determination method of the quality factor, which removes the influence of different earthquakes or propagation depth of scattered waves, may increase measurement precision, thus information pertaining to abnormal changes in quality factor and the relationship between the quality factor and earthquake preparation process can be acquired.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51021004, 51079096)the Program for New Century Excellent Talents in University (Grant No. NCET-08-0391)
文摘The conventional quality control method of core rocldill dam construction exhibit difficulty controlling compaction parameters accurately or ensuring construction quality. This is because it is easily influenced by human behavior or lack of adequate management. We therefore establish the timely monitoring indexes and control criteria of compaction processes by considering the characteristics and quality requirements of high core rockffll dam construction. Based on the established indexes and criteria, integrating GPS, GPRS and PDA technologies, a real-time compaction quality monitoring method is proposed. The relevant key techniques are proposed as well, including automatic collection of information and a graphic algorithm for rolling-process visualization. By the proposed method and techniques, a real-time monitoring system is provided to realize the precise automatic online entire-process monitoring of compaction parameters, including compaction pass, rolling trajectory, nmning speed of roller, vibration status and rolled pavement thickness. The application of the Nuozhadu project shows that the proposed system can control compaction parameters effectively and ensure better construction quality. Therefore, it might become a new way towards construction quality control of high core rockfill dam.
文摘Astronaut's body mass is an essential factor of health monitoring in space.The latest mass measurement device for the International Space Station (ISS) has employed a linear acceleration method.The principle of this method is that the device generates a constant pulling force,and the astronaut is accelerated on a parallelogram motion guide which rotates at a large radius to achieve a nearly linear trajectory.The acceleration is calculated by regression analysis of the displacement versus time trajectory and the body mass is calculated by using the formula m=F/a.However,in actual flight,the device is instable that the deviation between runs could be 6-7 kg.This paper considers the body non-rigidity as the major cause of error and instability and analyzes the effects of body non-rigidity from different aspects.Body non-rigidity makes the acceleration of the center of mass (C.M.) oscillate and fall behind the point where force is applied.Actual acceleration curves showed that the overall effect of body non-rigidity is an oscillation at about 7 Hz and a deviation of about 25%.To enhance body rigidity,better body restraints were introduced and a prototype based on linear acceleration method was built.Measurement experiment was carried out on ground on an air table.Three human subjects weighing 60-70 kg were measured.The average variance was 0.04 kg and the average measurement error was 0.4%.This study will provide reference for future development of China's own mass measurement device.
基金The support of this work by the National Natural Science Foundation of China under Grant No.50074006 is gratefully acknowledged.
文摘A temperature measurement model of radiation thermometry for the surface covered by participating media was developed. The model was based on the radiation heat transfer of participating media and principles of radiation pyrometers, and solved by integral formulation of discrete ordinate method on spectral waveband. The influence of water mist on the indicated temperature of Raytek MR1SB one/two color pyrometer was discussed. Mie theory was used to calculate the radiative properties of water mist. In order to verify the model, a laboratory temperature measurement experiment was executed. The result shows that temperature of radiation thermometry is sensitive to the spectral response wavelength of pyrometer, and the simulated temperature of pyrometer agrees well with the experimental measurements on a suitable wavelength. The simulated temperature was lower than the real temperature of surface for one-color pyrometer, and it could be higher or lower than the real one for two-color pyrometer with the influence of participating media.