Overall dispersed side volumetric mass transfer coefficients for protein and amino acids were measured in continuous countercurrent PEG4000/KHP aqueous two-phase systems in a 57mm I.D. packed extraction column. A mode...Overall dispersed side volumetric mass transfer coefficients for protein and amino acids were measured in continuous countercurrent PEG4000/KHP aqueous two-phase systems in a 57mm I.D. packed extraction column. A model for overall dispersed side volumetric mass transfer coefficients was derived by describing the motion of the drops based upon Navier-Stokes equation combined with the relationship between mass transfer coefficients and the drop velocity. The model provides good predictions and can be successfully used in aqueous two-phase extraction. The average relative deviation between calculated values and experimental data ranges from 8% to 14%.展开更多
A filed experiment was conducted continuously for three days,and the velocity variation was measured using coda wave interferometry.The measurement error is estimated to be around 10-4,which coincides well with the th...A filed experiment was conducted continuously for three days,and the velocity variation was measured using coda wave interferometry.The measurement error is estimated to be around 10-4,which coincides well with the theoretical error.The velocity variation during this period is up to 10-3.The relationship between velocity variation and changes in air temperature,barometric pressure and solid earth tide was analyzed with linear least square fitting.The velocity has no dependence on air temperature,but displayed change of the order of 10-6~10-7 when the barometer or earth tide changed one Pa.展开更多
Four rapid spectral comparison methods are introduced in mobile labs.They are conformity test method,general correlation coefficient method,reverse correlation coefficient method and correlation coefficient method usi...Four rapid spectral comparison methods are introduced in mobile labs.They are conformity test method,general correlation coefficient method,reverse correlation coefficient method and correlation coefficient method using characteristic spectral ranges.The first method is used for tracking the movements of drugs in the distribution channels;the second is used for quickly identify new counterfeit drugs;the last two are used to screen drugs illegally added in Traditional Chinese Medicine (TCM).The applicability of the four methods is evaluated with counterfeit and authentic drugs.Our results show that these methods can be quickly constructed and used to identify counterfeit drugs accurately.展开更多
基金Supported by the National Natural Science Foundation of China.
文摘Overall dispersed side volumetric mass transfer coefficients for protein and amino acids were measured in continuous countercurrent PEG4000/KHP aqueous two-phase systems in a 57mm I.D. packed extraction column. A model for overall dispersed side volumetric mass transfer coefficients was derived by describing the motion of the drops based upon Navier-Stokes equation combined with the relationship between mass transfer coefficients and the drop velocity. The model provides good predictions and can be successfully used in aqueous two-phase extraction. The average relative deviation between calculated values and experimental data ranges from 8% to 14%.
基金sponsored by the Special R & D Project of China Earthquake Administration(200808002)the Special Project of Basic Scientific Research of the Institute of Geophysics,CEA(DQJB08B13)
文摘A filed experiment was conducted continuously for three days,and the velocity variation was measured using coda wave interferometry.The measurement error is estimated to be around 10-4,which coincides well with the theoretical error.The velocity variation during this period is up to 10-3.The relationship between velocity variation and changes in air temperature,barometric pressure and solid earth tide was analyzed with linear least square fitting.The velocity has no dependence on air temperature,but displayed change of the order of 10-6~10-7 when the barometer or earth tide changed one Pa.
基金National Key Technologies R&D Program Foundation of China(Grant No.2008BAI55B06).
文摘Four rapid spectral comparison methods are introduced in mobile labs.They are conformity test method,general correlation coefficient method,reverse correlation coefficient method and correlation coefficient method using characteristic spectral ranges.The first method is used for tracking the movements of drugs in the distribution channels;the second is used for quickly identify new counterfeit drugs;the last two are used to screen drugs illegally added in Traditional Chinese Medicine (TCM).The applicability of the four methods is evaluated with counterfeit and authentic drugs.Our results show that these methods can be quickly constructed and used to identify counterfeit drugs accurately.