The effects and heat transfer mode of water film and sprinkler system on the heat-resistant property associated with the insulation of a fireproof glass were investigated. In the experiments, fireproof glass with a si...The effects and heat transfer mode of water film and sprinkler system on the heat-resistant property associated with the insulation of a fireproof glass were investigated. In the experiments, fireproof glass with a size of 3 300 mm (height)×2 200 mm (width) ×12 mm (thickness) was exposed to an oil pool fire with a power of approximately 1.4 MW. The experimental results show that the application of the water film or sprinkler system on the glass can effectively resist the intensive heat from the fire in the test due to the absorption of latent heat. The permitted period of integrity and insulation with a water film and a sprinkler system could be extended to 60 min. It should be noted that the temperature of the glass surface Can be kept under 60℃in a 60 min test. The experimental results suggest that it is feasible to substitute fireproof glass with water film for a fireproof door as long as the water film or sprinkler system can work stably and water can cover the whole surface of the frreproof glass.展开更多
Water shortage is an important constraint factor in the construction of the Three-North Shelterbelt (TNS). Here, we analyzed temporal-spatial patterns in water resources and trends in the Three-North region. We eval...Water shortage is an important constraint factor in the construction of the Three-North Shelterbelt (TNS). Here, we analyzed temporal-spatial patterns in water resources and trends in the Three-North region. We evaluated the water resource carrying capacity (WRCC) of 623 counties in the project area during the fifth phase of the TNS Development Program. Results show that 387 counties are appropriate for forestation, 185 counties can be planted, and 60 counties are inappropriate for forestation because of water resource constraints.展开更多
基金Project(2006BAK06B02) supported by the National Science and Technology Pillar Program during the Eleven Five-Year Plans of ChinaProject(70701019) supported by the National Natural Science Foundation of China
文摘The effects and heat transfer mode of water film and sprinkler system on the heat-resistant property associated with the insulation of a fireproof glass were investigated. In the experiments, fireproof glass with a size of 3 300 mm (height)×2 200 mm (width) ×12 mm (thickness) was exposed to an oil pool fire with a power of approximately 1.4 MW. The experimental results show that the application of the water film or sprinkler system on the glass can effectively resist the intensive heat from the fire in the test due to the absorption of latent heat. The permitted period of integrity and insulation with a water film and a sprinkler system could be extended to 60 min. It should be noted that the temperature of the glass surface Can be kept under 60℃in a 60 min test. The experimental results suggest that it is feasible to substitute fireproof glass with water film for a fireproof door as long as the water film or sprinkler system can work stably and water can cover the whole surface of the frreproof glass.
基金the Principal of State Science Key Project (NO. 2007FY110300)the National Natural Science Foundation Item (NO. 41101117)
文摘Water shortage is an important constraint factor in the construction of the Three-North Shelterbelt (TNS). Here, we analyzed temporal-spatial patterns in water resources and trends in the Three-North region. We evaluated the water resource carrying capacity (WRCC) of 623 counties in the project area during the fifth phase of the TNS Development Program. Results show that 387 counties are appropriate for forestation, 185 counties can be planted, and 60 counties are inappropriate for forestation because of water resource constraints.