Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patient...Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patients with PDA (n = 25) and ASD ( n = 16), confirmed byechocardiography, were treated by transcatheterization. Amplatzer occluder device was placed by thetranscatheterization with the image support of X-ray and transthoracic echocardiography ( TTE) . TheTTE, ECG and X-ray examination were engaged to evaluate the therapeutic results on the time pointsof 24 h , 1, 3 , 6, 12 months after the operation, and all these cases were engaged to the follow-upexamination. Results: The cardioangiographic diameter was 13.0-28.0 mm ([19.3+-4.9] mm) in ASD and2.0-7.7 mm ([3.9+-1.5] mm) in PDA . The diameter of the Amplatzer occluder selected were 13.0-30.0mm ( [20.6+-5.1] mm) in ASD and 4.0-12.0 mm ([6.6+-1.9] mm) in PDA , respectively. All the Amplatzeroccluders were placed successfully. There were no complications during and after the operation.Very small residual shunt was still found soon after the operation in 10 cases , and there were noresidual or recanalization after three months of the operation. The pulmonary artery pressure andheart size were significantly decreased in follow-up examination . Conclusion: Transcatheteringclosure with Amplatzer device is an effective, simple and safe technique in the treatment of ASD andPDA in children.展开更多
AIM: To investigate the rate of complications of endoscopic retrograde cholangio-pancreatography (ERCP) performed immediately after endoscopic ultrasound fine needle aspiration (EUS-FNA) in a large series of patients....AIM: To investigate the rate of complications of endoscopic retrograde cholangio-pancreatography (ERCP) performed immediately after endoscopic ultrasound fine needle aspiration (EUS-FNA) in a large series of patients. METHODS: Patients with the following conditions were considered candidates for EUS-FNA and ERCP: diagnosis of locally advanced or metastatic pancreatic lesion not eligible for surgery, and patients with pancreatic lesion of unknown nature causing jaundice. Data were prospectively collected on the following parameters: indication for FNA, EUS findings, pathological diagnosis, procedure duration of EUS-FNA and combined EUS-FNA and ERCP, and immediate and late complications. RESULTS: From January 2004 to October 2006, 72 patients were deemed eligible for combined EUS and ERCP. In 25/72 EUS-FNA was performed to obtain a pathology diagnosis of lesions causing biliary obstruction, and ERCP sequentially performed to drain the biliary system. No immediate complications occurred except for two mild bleeding episodes post sphincterotomy. No late complications were recorded except for one patient who experienced fever, promptly recovered with antibiotic therapy. CONCLUSION: Simultaneous approach appears to be feasible and safe. When possible, this can be considered the reference standard to avoid double sedation and reduce duration of the procedure and hospital stay.展开更多
Method Fifteen hundred and fifty two patients with heart disease were examined with monoplane, biplane and omniplane TEE probe(including male 727, female 825;9~76 years old) During the s...Method Fifteen hundred and fifty two patients with heart disease were examined with monoplane, biplane and omniplane TEE probe(including male 727, female 825;9~76 years old) During the same period, 113 307 precordial echocardiographic examinations were performed in our laboratory The ratio between TEE and transthoracic Echo examines was 1:73 Result All different kinds of complication were occurred during TEE examination, including vomiting, minor mucus bleeding, laryngospasm, mandibular dislocation, angina pectoris, arrhythmia, even ventricular fibrillation and death The article suggested that there were five steps must be improved during TEE examination including instrument and patients preparation, local anesthesia, manipulation technique and TEE probes pattern Conclusion Although TEE is a semiinvasive technique and can cause some kinds of complication, it is a safe technique if the five steps are improved展开更多
文摘Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patients with PDA (n = 25) and ASD ( n = 16), confirmed byechocardiography, were treated by transcatheterization. Amplatzer occluder device was placed by thetranscatheterization with the image support of X-ray and transthoracic echocardiography ( TTE) . TheTTE, ECG and X-ray examination were engaged to evaluate the therapeutic results on the time pointsof 24 h , 1, 3 , 6, 12 months after the operation, and all these cases were engaged to the follow-upexamination. Results: The cardioangiographic diameter was 13.0-28.0 mm ([19.3+-4.9] mm) in ASD and2.0-7.7 mm ([3.9+-1.5] mm) in PDA . The diameter of the Amplatzer occluder selected were 13.0-30.0mm ( [20.6+-5.1] mm) in ASD and 4.0-12.0 mm ([6.6+-1.9] mm) in PDA , respectively. All the Amplatzeroccluders were placed successfully. There were no complications during and after the operation.Very small residual shunt was still found soon after the operation in 10 cases , and there were noresidual or recanalization after three months of the operation. The pulmonary artery pressure andheart size were significantly decreased in follow-up examination . Conclusion: Transcatheteringclosure with Amplatzer device is an effective, simple and safe technique in the treatment of ASD andPDA in children.
文摘AIM: To investigate the rate of complications of endoscopic retrograde cholangio-pancreatography (ERCP) performed immediately after endoscopic ultrasound fine needle aspiration (EUS-FNA) in a large series of patients. METHODS: Patients with the following conditions were considered candidates for EUS-FNA and ERCP: diagnosis of locally advanced or metastatic pancreatic lesion not eligible for surgery, and patients with pancreatic lesion of unknown nature causing jaundice. Data were prospectively collected on the following parameters: indication for FNA, EUS findings, pathological diagnosis, procedure duration of EUS-FNA and combined EUS-FNA and ERCP, and immediate and late complications. RESULTS: From January 2004 to October 2006, 72 patients were deemed eligible for combined EUS and ERCP. In 25/72 EUS-FNA was performed to obtain a pathology diagnosis of lesions causing biliary obstruction, and ERCP sequentially performed to drain the biliary system. No immediate complications occurred except for two mild bleeding episodes post sphincterotomy. No late complications were recorded except for one patient who experienced fever, promptly recovered with antibiotic therapy. CONCLUSION: Simultaneous approach appears to be feasible and safe. When possible, this can be considered the reference standard to avoid double sedation and reduce duration of the procedure and hospital stay.
文摘Method Fifteen hundred and fifty two patients with heart disease were examined with monoplane, biplane and omniplane TEE probe(including male 727, female 825;9~76 years old) During the same period, 113 307 precordial echocardiographic examinations were performed in our laboratory The ratio between TEE and transthoracic Echo examines was 1:73 Result All different kinds of complication were occurred during TEE examination, including vomiting, minor mucus bleeding, laryngospasm, mandibular dislocation, angina pectoris, arrhythmia, even ventricular fibrillation and death The article suggested that there were five steps must be improved during TEE examination including instrument and patients preparation, local anesthesia, manipulation technique and TEE probes pattern Conclusion Although TEE is a semiinvasive technique and can cause some kinds of complication, it is a safe technique if the five steps are improved