To determine a surgical procedure for the correction of a systemic arterial s upply to a normal lung, it is important to evaluate whether the patient has a pu lmonary arteriovenous fistula. In this article, the author...To determine a surgical procedure for the correction of a systemic arterial s upply to a normal lung, it is important to evaluate whether the patient has a pu lmonary arteriovenous fistula. In this article, the authors report for the first time a patient in which selective contrast echocardiography and selective perfu sion scintigraphy from an abnormal artery clearly demonstrated and quantified th e pulmonary arteriovenousfistula. The authors believe that these methods are use ful in determining the appropriate operative procedure for this condition.展开更多
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto...To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.展开更多
Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Ca...Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD), and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by ther-modilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.展开更多
Objectives: To directly compare the quality of harmonic imaging (HI) and fundamental imaging (FI) in fetal echocardiography and to determine any differences in image quality between the two modalities. Methods: Feta...Objectives: To directly compare the quality of harmonic imaging (HI) and fundamental imaging (FI) in fetal echocardiography and to determine any differences in image quality between the two modalities. Methods: Fetal echocardiograms were performed with the use of FI and HI in 58 fetuses, image quality and visualization of left and right atria, left and right ventricles, mitral and tricuspid valves, aortic and pulmonary valves, left and right ventricular outflow tracts were evaluated and compared between FI and HI. Results: Mean HI scores were higher than mean FI scores (2.73±0.43 vs 2.16±0.69, P <0.001)for all the cardiovascular structures evaluated. Compared with FI, HI improved the image quality and visualization of fetal cardiac structures in subjects with both good (2.73±0.43 vs 2.88±0.32, P <0.001) and suboptimal (1.65±0.41 vs 2.58±0.47, P <0.001) echocardiographic windows. The interobserver correlation coefficient for the grading scores was 0.74 ( P <0.001). Conclusions: harmonic imaging enhances and improves the image quality of fetal echocardiography; and has important potential role in cardiac imaging in the fetus.展开更多
文摘To determine a surgical procedure for the correction of a systemic arterial s upply to a normal lung, it is important to evaluate whether the patient has a pu lmonary arteriovenous fistula. In this article, the authors report for the first time a patient in which selective contrast echocardiography and selective perfu sion scintigraphy from an abnormal artery clearly demonstrated and quantified th e pulmonary arteriovenousfistula. The authors believe that these methods are use ful in determining the appropriate operative procedure for this condition.
文摘To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.
文摘Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD), and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by ther-modilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.
文摘Objectives: To directly compare the quality of harmonic imaging (HI) and fundamental imaging (FI) in fetal echocardiography and to determine any differences in image quality between the two modalities. Methods: Fetal echocardiograms were performed with the use of FI and HI in 58 fetuses, image quality and visualization of left and right atria, left and right ventricles, mitral and tricuspid valves, aortic and pulmonary valves, left and right ventricular outflow tracts were evaluated and compared between FI and HI. Results: Mean HI scores were higher than mean FI scores (2.73±0.43 vs 2.16±0.69, P <0.001)for all the cardiovascular structures evaluated. Compared with FI, HI improved the image quality and visualization of fetal cardiac structures in subjects with both good (2.73±0.43 vs 2.88±0.32, P <0.001) and suboptimal (1.65±0.41 vs 2.58±0.47, P <0.001) echocardiographic windows. The interobserver correlation coefficient for the grading scores was 0.74 ( P <0.001). Conclusions: harmonic imaging enhances and improves the image quality of fetal echocardiography; and has important potential role in cardiac imaging in the fetus.