期刊文献+
共找到153篇文章
< 1 2 8 >
每页显示 20 50 100
Application progresses of ultrasound for snakebites and relative complications
1
作者 ZHENG Yiyin SHEN Yanyan BIN Wenkai 《中国医学影像技术》 CSCD 北大核心 2024年第8期1258-1261,共4页
Snakebite has become a serious public health problem with high mortality and disability rates.Ultrasound can provide imaging basis for diagnosis and treatment of snakebites and relative complications.The application p... Snakebite has become a serious public health problem with high mortality and disability rates.Ultrasound can provide imaging basis for diagnosis and treatment of snakebites and relative complications.The application progresses of ultrasound in snakebites and complications were reviewed in this article. 展开更多
关键词 snake bites ULTRASONOGRAPHY DIAGNOSIS
下载PDF
Ultrasonic manifestations and age distribution of internal abdominal hernia in children
2
作者 KUANG Bin YANG Chunjiang TANG Yi 《中国医学影像技术》 CSCD 北大核心 2024年第8期1204-1207,共4页
Objective To observe the ultrasonic manifestations and age distribution of internal abdominal hernia in children.Methods Data of 53 children with internal abdominal hernia confirmed by operation were retrospectively a... Objective To observe the ultrasonic manifestations and age distribution of internal abdominal hernia in children.Methods Data of 53 children with internal abdominal hernia confirmed by operation were retrospectively analyzed.The ultrasonic findings were observed,and the age distribution of children was analyzed.Results Among 53 cases,"cross sign"was observed in 22 cases(22/53,41.51%),and"hernia ring beak sign"was detected in 26 cases(26/53,49.06%)by preoperative ultrasound,according to which 21 cases were diagnosed as internal abdominal hernia,with the accuracy of 39.62%(21/53).Meanwhile,manifestations of intestinal obstruction were noticed in 48 cases(48/53,90.57%),and intestinal necrosis was considered in 22 cases(22/53,41.51%).Four cases were misdiagnosed as intestinal perforation,appendicitis,intestinal atresia and volvulus,each in 1 case.The onset age of postoperative adhesive band internal hernia was larger than that of mesenteric hiatal hernia(P<0.05),while no significant difference of onset age was found among other types of internal abdominal hernias(all P>0.05).Intestinal ischemic necrosis was found in 25 cases,while the incidence of intestinal necrosis in children aged≤1 year,>1 and≤3 years,>3 and≤7 years and those>7 years was 66.67%(12/18),33.33%(4/12),36.36%(4/11)and 41.67%(5/12),respectively.Conclusion The characteristic ultrasonic findings of internal abdominal hernia in children included"cross sign"and"hernia ring beak sign".Internal abdominal hernia in children under 1 year had high risk of intestinal necrosis. 展开更多
关键词 hernia abdominal CHILDREN ULTRASONOGRAPHY
下载PDF
Correlations of transcranial sonography of substantia nigra characteristics with MRI iron deposition on substantia nigra in patients with Parkinson disease
3
作者 ZOU Quan CHEN Fei +1 位作者 MENG Wenyu ZHENG Hong 《中国医学影像技术》 CSCD 北大核心 2024年第8期1160-1163,共4页
Objective To explore the correlations of transcranial sonography of substantia nigra(SN-TCS)characteristics with MRI iron deposition on substantia nigra in patients with Parkinson disease(PD).Methods Data of SN-TCS an... Objective To explore the correlations of transcranial sonography of substantia nigra(SN-TCS)characteristics with MRI iron deposition on substantia nigra in patients with Parkinson disease(PD).Methods Data of SN-TCS and craniocerebral MRI in 120 PD patients were retrospectively analyzed.The patients were divided into iron deposition positive group(positive group,n=46)and iron deposition negative group(negative group,n=74)according to quantitative susceptibility mapping(QSM)value.Then parameters of SN-TCS and MRI were compared between groups(both P<0.05),and correlation analysis were also performed.Results The proportion of high echo positive,strong echo area and QSM value of substantia nigra,as well as of hyper-substantia nigra area/midbrain area(S/M)in positive group were all higher than those in negative group(all P<0.001).No significant difference of midbrain area was found between groups(P>0.05).Strong echo area of substantia nigra and S/M based on SN-TCS were both low-medium positively correlated with substantia nigra QSM value showed on MRI(r=0.497,0.529,both P<0.001).Conclusion SN-TCS characteristics of PD patients were correlated with MRI iron deposition on substantia nigra,among which strong echo area and S/M were valuable for evaluating iron deposition on substantia nigra. 展开更多
关键词 Parkinson disease substantia nigra IRON ULTRASONOGRAPHY magnetic resonance imaging
下载PDF
Cranial ultrasound in perioperative period of acute severe traumatic brain injury
4
作者 WANG Yangang LYU Zhenpu +4 位作者 ZHENG Xianzhao QIN Zheng LI Jianxin GE Ran ZHAO Feifei 《中国医学影像技术》 CSCD 北大核心 2024年第8期1156-1159,共4页
Objective To observe the value of cranial ultrasound for perioperative patients with acute severe traumatic brain injury(sTBI).Methods Data of 55 sTBI patients who underwent craniotomy were retrospectively analyzed.Th... Objective To observe the value of cranial ultrasound for perioperative patients with acute severe traumatic brain injury(sTBI).Methods Data of 55 sTBI patients who underwent craniotomy were retrospectively analyzed.The patients were divided into observation group(n=15)and control group(n=40)according to received perioperative cranial ultrasound or not.The general data and surgical data were compared between groups,and ultrasonic data of observation group were analyzed.Results The proportions of good prognosis 1 and 6 months after operation in observation group were both higher than those in control group,while the incidence of cerebral infarction in observation group was lower than that in control group(all P<0.05).No significant difference of general data nor other surgical data was found between groups(all P>0.05).Acute encephalocele occurred in 1 case in observation group during operation,and cranial ultrasound accurately showed the contralateral secondary epidural hematoma.Increased intracranial pressure in different degrees were found in all 15 cases(15/15,100%)in observation group after operation with transcranial color coded Doppler(TCCD)or transcranial Doppler(TCD),while cerebral vascular spasm was observed in 5 cases(5/15,33.33%),among them 4 cases(4/5,80.00%)were diagnosed cerebral infarction based on CT examination.Conclusion Cranial ultrasound could be used to evaluate changes of sTBI in perioperative period and guide adjusting treatment strategy in time,being valuable for reducing risk of postoperative cerebral infarction and improving prognosis. 展开更多
关键词 craniocerebral trauma perioperative period ULTRASONOGRAPHY
下载PDF
Contrast-enhanced ultrasound for predicting differentiation degree of hepatocellular carcinoma
5
作者 REN Youxiang LING Wenwu +1 位作者 LUO Yan YANG Lulu 《中国医学影像技术》 CSCD 北大核心 2024年第8期1199-1203,共5页
Objective To explore the value of contrast-enhanced ultrasound(CEUS)for predicting differentiation degree of hepatocellular carcinoma(HCC).Methods Totally 86 HCC patients confirmed by postoperative pathology were retr... Objective To explore the value of contrast-enhanced ultrasound(CEUS)for predicting differentiation degree of hepatocellular carcinoma(HCC).Methods Totally 86 HCC patients confirmed by postoperative pathology were retrospectively enrolled and divided into poorly differentiated,moderately differentiated and highly differentiated groups according to postoperative Edmondson-Steiner grading.Preoperative CEUS parameters were compared among groups,and binary logistic regression was used to analyze CEUS-related independent predictors of HCC with different differentiation.The receiver operating characteristic curves of parameters being significant different among groups were drawn,the areas under the curve(AUC)were calculated,and the efficacy for predicting HCC with different differentiation degree was evaluated.Results There were 29 cases in poorly differentiated group,37 in moderately differentiated group and 20 cases in highly differentiated group.The arrival time of contrast agent in poorly differentiated group was earlier than that in moderately and high differentiated groups(both P<0.05),while in moderately differentiated group was not significantly different with that in highly differentiated group(P>0.05).The washout grade were significantly different between each 2 groups(all P<0.05).The arrival time of contrast agent and washout grade were independent predictors of highly or poorly differentiated,moderately or poorly differentiated,moderate-highly or poorly differentiated HCC,and washout grade also was independent predictor of highly or moderately differentiated HCC(all P<0.05).The AUC of the arrival time of contrast agent for predicting highly or moderately differentiated,highly or poorly differentiated,moderately or poorly differentiated,moderate-highly or poorly differentiated HCC was 0.615,0.787,0.690 and 0.724,respectively,while of washout grade was 0.801,0.927,0.795 and 0.841,respectively.Conclusion CEUS could be used to effectively predict differentiation degree of HCC. 展开更多
关键词 carcinoma hepatocellular ULTRASONOGRAPHY pathological differentiation
下载PDF
E-Cervix imaging displaying cervical elasticity characteristics of healthy adult nulliparous women at different age groups and different menstrual cycle stages
6
作者 XU Yunyan WANG Mingli +1 位作者 LYU Xiaoli LI Xuelei 《中国医学影像技术》 CSCD 北大核心 2024年第8期1208-1211,共4页
Objective To observe the cervical elasticity of healthy adult nulliparous women at different age groups and different stages of menstrual cycle with E-Cervix imaging technology.Methods A total of 218 healthy adult nul... Objective To observe the cervical elasticity of healthy adult nulliparous women at different age groups and different stages of menstrual cycle with E-Cervix imaging technology.Methods A total of 218 healthy adult nulliparous women who underwent transvaginal ultrasound examination for routine physical examination were retrospectively enrolled,including 103 in follicular phase,78 in ovulation phase and 37 in luteal phase.Cervical canal length(CL)and E-Cervix elasticity parameters were compared among different age groups and different stages of menstrual cycle,including elasticity contrast index(ECI),hardness ratio(HR),cervical internal and external orifice strain values(IOS and EOS)and IOS/EOS ratio.Results No significant difference of CL nor cervical elasticity parameters was detected among healthy adult nulliparous women at different age groups(all P>0.05).There were significant differences of ECI,HR and IOS among different menstrual cycle stages(all P<0.05),among which women in follicular phase had higher ECI and IOS but lower HR than those in luteal phase(all P<0.05).Conclusion No significant difference of cervical elasticity existed among healthy adult nulliparous women at different age groups.Meanwhile,cervical elasticity of healthy adult nulliparous women changed during menstrual cycle,in follicular phase had higher ECI and IOS but lower HR than in luteal phase. 展开更多
关键词 cervix uteri MENSTRUATION ULTRASONOGRAPHY elasticity imaging techniques
下载PDF
Ultrafast pulse wave velocity technique for evaluating changes of carotid artery elasticity in Hashimoto thyroiditis patients with euthyroidism
7
作者 JIANG Yanhui LIU Meiling +1 位作者 XIE Jingwen ZHANG Jianxing 《中国医学影像技术》 CSCD 北大核心 2024年第8期1179-1182,共4页
Objective To explore the value of ultrafast pulse wave velocity(UFPWV)technique for evaluating changes of carotid artery elasticity in Hashimoto thyroiditis(HT)patients with euthyroidism.Methods Conventional ultrasoun... Objective To explore the value of ultrafast pulse wave velocity(UFPWV)technique for evaluating changes of carotid artery elasticity in Hashimoto thyroiditis(HT)patients with euthyroidism.Methods Conventional ultrasound and UFPWV for carotid artery were prospectively performed in 91 HT patients with euthyroidism(HT group)and 81 healthy subjects(control group).Clinical data and ultrasonic parameters were compared between groups.Spearman correlation analysis was performed to observe the correlations of carotid pulse wave velocity in end of systole(PWV-ES)with clinical indexes and other ultrasonic parameters in HT group.Multiple stepwise linear regression analysis was used to screen the independent impact factors of increased carotid PWV-ES in HT group.Results Significant differences of thyroid peroxidase antibody(TPOAb),thyroglobulin antibody(TgAb),total cholesterol(TC),low density lipoprotein and neutrophil-lymphocyte ratio(NLR)were found between groups(all P<0.05).The carotid PWV-ES in HT group was significantly higher than that in control group(P<0.05),while no significant difference of carotid artery intima-media thickness(CIMT)nor carotid pulse wave velocity in beginning of systole(PWV-BS)was found between groups(both P>0.05).Carotid PWV-ES in HT group was positively correlated with patients'age,body mass index,TPOAb,TC,triglyceride,NLR and CIMT(r=0.217—0.707,all P<0.05).Patients'age,TPOAb and NLR were all independent impact factors of increased carotid PWV-ES in HT patients with euthyroidism(all P<0.05).Conclusion UFPWV technique could be used to evaluate changes of carotid artery elasticity in HT patients with euthyroidism,among which PWV-ES was relatively sensitive. 展开更多
关键词 Hashimoto disease carotid arteries ULTRASONOGRAPHY prospective studies
下载PDF
Polar residual network model for assisting evaluation on rat myocardial infarction segment in myocardial contrast echocardiography
8
作者 SHEN Wenqian GUO Yanhui +5 位作者 YU Bo CHEN Shuang LI Hairu WU Yan LI You DU Guoqing 《中国医学影像技术》 CSCD 北大核心 2024年第8期1130-1134,共5页
Objective To investigate the value of polar residual network(PResNet)model for assisting evaluation on rat myocardial infarction(MI)segment in myocardial contrast echocardiography(MCE).Methods Twenty-five male SD rats... Objective To investigate the value of polar residual network(PResNet)model for assisting evaluation on rat myocardial infarction(MI)segment in myocardial contrast echocardiography(MCE).Methods Twenty-five male SD rats were randomly divided into MI group(n=15)and sham operation group(n=10).MI models were established in MI group through ligation of the left anterior descending coronary artery using atraumatic suture,while no intervention was given to those in sham operation group after thoracotomy.MCE images of both basal and papillary muscle levels on the short axis section of left ventricles were acquired after 1 week,which were assessed independently by 2 junior and 2 senior ultrasound physicians.The evaluating efficacy of MI segment,the mean interpretation time and the consistency were compared whether under the assistance of PResNet model or not.Results No significant difference of efficacy of evaluation on MI segment was found for senior physicians with or without assistance of PResNet model(both P>0.05).Under the assistance of PResNet model,the efficacy of junior physicians for diagnosing MI segment was significantly improved compared with that without the assistance of PResNet model(both P<0.01),and was comparable to that of senior physicians.Under the assistance of PResNet model,the mean interpretation time of each physician was significantly shorter than that without assistance(all P<0.001),and the consistency between junior physicians and among junior and senior physicians were both moderate(Kappa=0.692,0.542),which became better under the assistance(Kappa=0.763,0.749).Conclusion PResNet could improve the efficacy of junior physicians for evaluation on rat MI segment in MCE images,shorten interpretation time with different aptitudes,also improve the consistency to some extent. 展开更多
关键词 myocardial infarction deep learning ULTRASONOGRAPHY animal experimentation
下载PDF
Real-time shear wave elastography combined with biochemical indicators for evaluating liver injury in patients with chronic kidney disease
9
作者 FAN Xiangyang ZHANG Yan +2 位作者 HE Xiao WANG Ziwei YU Jing 《中国医学影像技术》 CSCD 北大核心 2024年第8期1221-1225,共5页
Objective To observe the value of real-time shear wave elastography(SWE)combined with biochemical indicators for evaluating liver injury in patients with chronic kidney disease(CKD).Methods Totally 210 patients with C... Objective To observe the value of real-time shear wave elastography(SWE)combined with biochemical indicators for evaluating liver injury in patients with chronic kidney disease(CKD).Methods Totally 210 patients with CKD(CKD group)and 64 healthy subjects(control group)were retrospectively enrolled.Patients in CKD group were further divided into CKD1—5 subgroups according to CKD stages.SWE parameters of liver and kidney,including mean value,the maximum value and the median value of Young's modulus(EQI mean,EQI max and EQI med)were compared between CKD subgroups and control group.Spearman correlation analysis were performed to explore the correlations of liver and kidney SWE parameters with CKD stage,as well as of liver SWE parameters with biochemical indicators.Multivariate logistic regression analysis was used to screen independent predictors of liver injury in CKD patients.Receiver operating characteristic curves were drawn,the area under the curves(AUC)were calculated to evaluate the efficacy of the independent predictors alone and their combination for assessing liver injury in CKD patients.Results Significant differences of liver and kidney SWE parameters were found among CKD subgroups and control group(all P≤0.001).Pairwise comparison showed that liver SWE parameters in CKD5 subgroup and liver EQI max in CKD4 subgroup were all higher than those in control group(all P<0.003).Kidney SWE parameters in CKD3 subgroup were all higher than those in control group,while in CKD4 subgroup were all higher than those in control group and CKD1—3 subgroup(all P<0.003).Kidney EQI mean and EQI med in CKD5 subgroup were all higher than those in control group and CKD1—4 subgroup,while kidney EQI max in CKD5 subgroup were higher than those in control group and CKD1—3 subgroup(all P<0.003).Liver and kidney SWE parameters were lowly-moderately and positively correlated with CKD stages(r=0.364—0.665,all P<0.001).Liver SWE parameters of CKD were weakly and positively correlated with alkaline phosphatase(ALP)(r=0.229—0.248,all P<0.01).Theγ-glutamyl transferase,ALP and liver EQI max were all independent predictors of liver injury in CKD patients(all P<0.01),with AUC for evaluating liver injury in CKD patients alone of 0.645,0.756 and 0.741,respectively,lower than that of their combination(0.851,all P<0.01).Conclusion Real-time SWE combined with liver function indicators could reflect degree of liver injury in patients with different CKD stages. 展开更多
关键词 renal insufficiency chronic hepatic insufficiency ULTRASONOGRAPHY
下载PDF
Prenatal ultrasonic characteristics and diagnosis of fetal Currarino syndrome:Report of 2 cases and review of literature
10
作者 WEI Yingni ZHANG Yuchen +3 位作者 DENG Zongfeng WANG Yingqiu HUANG Qiaojie CHEN Yayan 《中国医学影像技术》 CSCD 北大核心 2024年第8期1212-1215,共4页
Objective To explore prenatal ultrasonic characteristics of fetal Currarino syndrome(CS)and methods for prenatal diagnosis of CS.Methods Two fetuses with CS confirmed by genetic examination were retrospectively analyz... Objective To explore prenatal ultrasonic characteristics of fetal Currarino syndrome(CS)and methods for prenatal diagnosis of CS.Methods Two fetuses with CS confirmed by genetic examination were retrospectively analyzed,while 6 CS fetuses with complete prenatal ultrasonic data in literature were reviewed.Prenatal ultrasonic characteristics of CS fetuses and the method for prenatal diagnosis of CS were discussed.Results Among 8 CS fetuses diagnosed with prenatal ultrasound,4 were female singletons with a clear family history of CS,and MNX 1 gene mutation was found in 1 fetus.The other 4 fetuses were 2 pairs of male monochorionic twins,all with MNX 1 gene mutation.Among 8 CS fetuses,complete triad(sacral agenesis abnormalities,anorectal malformation and presacral mass)were displayed only in 2 fetuses,while all 8 had sacral agenesis abnormalities and 6(6/8,75.00%)were detected with prenatal ultrasound,6 had low location of conus medullaris and 2(2/6,33.33%)detected with prenatal ultrasound.Conclusion Prenatal ultrasound was the first choice for non-invasive diagnosis of fetal CS.When one of sacral agenesis abnormalities,anorectal malformation and presacral mass was found with prenatal ultrasound,the possibility of CS should be considered,and fetal MRI,genetic examination and prenatal genetic counselling should be recommended if necessary. 展开更多
关键词 Currarino triad ultrasonography prenatal AMNIOCENTESIS GENES
下载PDF
Right heart modified myocardial performance index and ductus venosus spectrum parameters in pre-eclampsia fetuses for predicting adverse pregnancy outcomes
11
作者 GAO Jing LI Hezhou +4 位作者 WANG Ming WU Juan WANG Xinxia LIU Yun ZHU Ziqi 《中国医学影像技术》 CSCD 北大核心 2024年第8期1146-1150,共5页
Objective To observe the values of changes of right heart modified myocardial performance index(Mod-MPI)and ductus venosus(DV)spectrum parameters in pre-eclampsia fetuses for predicting adverse pregnancy outcomes.Meth... Objective To observe the values of changes of right heart modified myocardial performance index(Mod-MPI)and ductus venosus(DV)spectrum parameters in pre-eclampsia fetuses for predicting adverse pregnancy outcomes.Methods Eighty-one pregnant women diagnosed as pre-eclampsia were prospectively enrolled and divided into severe pre-eclampsia(SPE)group(n=39)and mild pre-eclampsia(MPE)group(n=42),while 85 healthy pregnant women were taken as controls(control group).Fetal right heart function parameters,including right ventricular isovolumetric relaxation time(IRT),isovolumetric contraction time(ICT),ejection time(ET),total spent time(TST),Mod-MPI,tricuspid valve peak flow velocity ratio in early and late diastole(TV-E/A),as well as blood flow velocities in each waveform of DV spectrum(S,V,D,and A wave)were obtained,and the pulsatility index(PI)and the ratio of blood flow velocities in each waveform of the DV(S/V,S/D,S/A,V/D,V/A,D/A)were calculated.Intrauterine fetal distress,preterm delivery,neonatal asphyxia and newborn with low weight were considered as adverse pregnancy outcomes.The correlations of right heart Mod-MPI and TV-E/A with DV parameters in pre-eclampsia fetuses were assessed,and their predictive efficacies for adverse pregnancy outcomes were evaluated for right heart Mod-MPI and DV using the receiver operating characteristics(ROC)and the area under the curves(AUC).Results Compared with control group and MPE group,fetal right heart IRT,ICT and Mod-MPI increased and ET decreased in SPE group(all P<0.05).No significant differences of right heart TST and TV-E/A among 3 groups(both P>0.05).Fetal DV A-wave velocity and V/D values progressively decreased but PI progressively increased in control,MPE and SPE groups(all P<0.05).Fetal right heart Mod-MPI in pre-eclampsia was moderately positively correlated with DV PI(r=0.637,P=0.016),while TV-E/A was weakly negatively correlated with DV V/D(r=-0.355,P=0.043).Adverse pregnancy outcomes were noticed in 59 pre-eclampsia cases.The AUC of fetal right heart Mod-MPI and DV PI for predicting adverse pregnancy outcomes in pre-eclampsia cases was 0.897 and 0.848,respectively,without significant difference(Z=0.460,P=0.400).Conclusion Changes of right heart Mod-MPI and DV spectrum parameters in pre-eclampsia fetuses had high value for predicting adverse pregnancy outcomes. 展开更多
关键词 PRE-ECLAMPSIA fetal heart ventricular function ultrasonography prenatal prospective studies
下载PDF
彩色多普勒超声对肾动脉狭窄的诊断价值 被引量:1
12
作者 常群英 杨春梅 曹学平 《中国误诊学杂志》 CAS 2012年第18期4992-4993,共2页
目的探讨彩色多普勒超声检查在临床诊断肾动脉狭窄中的诊断价值。方法应用彩色多普勒超声对2009-02-2012—01对漯河市第三人民医院疑为肾性高血压患者进行彩色多普勒超声检测,诊断出肾动脉狭窄患者18例,并经肾动脉造影证实。结果彩色... 目的探讨彩色多普勒超声检查在临床诊断肾动脉狭窄中的诊断价值。方法应用彩色多普勒超声对2009-02-2012—01对漯河市第三人民医院疑为肾性高血压患者进行彩色多普勒超声检测,诊断出肾动脉狭窄患者18例,并经肾动脉造影证实。结果彩色多普勒超声根据肾动脉狭窄处血流的动力学改变来诊断肾动脉狭窄,统计结果显示,肾动脉狭窄时,主肾动脉狭窄处血流峰速(PSV)加快,PSV1.5~3.2m/s,平均2.3m/s,肾动脉峰值流速与肾动脉开口处腹主动脉流速之比(RAR)升高,RAR:2.6~3.9,平均3.2,狭窄下游肾内动脉收缩早期加速时间(AT)延长,收缩早期加速度(AC)减低,AT:0.12~0.37s,AC:1.1~2.9m/s2。结论彩色多普勒超声检查对肾动脉狭窄诊断价值是肯定的,可起到重要的辅助确诊作用,为临床诊断及鉴别诊断此病,提供了一种简便、灵敏的新方法。但需要通过综合诊断,以免误诊。也可以作为本病血管造影前的筛选工具。 展开更多
关键词 肾动脉梗阻/检查 超检查声 多普勒 彩色
原文传递
产前超声诊断胎儿单纯肺动脉狭窄 被引量:8
13
作者 张颖 蔡爱露 +3 位作者 赵一理 李婷 姜克新 韩冰 《中华超声影像学杂志》 CSCD 北大核心 2009年第5期408-410,共3页
目的探讨产前超声诊断胎儿单纯肺动脉狭窄的方法与技巧,提高产前诊断率。方法回顾性分析18例超声诊断为胎儿单纯肺动脉狭窄的病例资料,对各切面超声特点进行分析总结。结果18例中5例经尸检证实,12例经产后超声证实为肺动脉瓣狭窄,1... 目的探讨产前超声诊断胎儿单纯肺动脉狭窄的方法与技巧,提高产前诊断率。方法回顾性分析18例超声诊断为胎儿单纯肺动脉狭窄的病例资料,对各切面超声特点进行分析总结。结果18例中5例经尸检证实,12例经产后超声证实为肺动脉瓣狭窄,1例经产后超声证实为肺动脉瓣闭锁。18例中动脉导管弓切面均可检出动脉导管内的反向血流,部分有右房增大、右室心肌肥厚、三尖瓣反流、卵圆孔增大及卵圆瓣活动度减低等征象。结论动脉导管弓切面检出动脉导管的反向血流及三血管切面内主动脉与肺动脉血流方向相反,对诊断胎儿单纯肺动脉狭窄具有重要提示作用,动脉导管弓切面、双流出道切面及三血管切面是诊断该病的重要切面。 展开更多
关键词 检查 产前 胎儿心脏 肺动脉瓣狭窄
原文传递
Assessment of flexural properties of different grade dimension lumber by ultrasonic technique 被引量:2
14
作者 江京辉 吕建雄 +2 位作者 任海青 龙超 骆秀琴 《Journal of Forestry Research》 SCIE CAS CSCD 2007年第4期305-308,共4页
The dimension lumber (45mm×90mm×3700mm) of plantation Chinese fir (Cunninghamia lanceolata (Lamb.) Hook.) was graded to four different classes as SS, No. 1, No.2 and No.3, according to national lumber ... The dimension lumber (45mm×90mm×3700mm) of plantation Chinese fir (Cunninghamia lanceolata (Lamb.) Hook.) was graded to four different classes as SS, No. 1, No.2 and No.3, according to national lumber grades authority (NLGA) for structure light framing and structure joists and planks. The properties of apparent density was determined at 15% moisture content, bending strength and stiffness were tested according to American Society for Testing and Materials (ASTM) D198-99, and dynamic modulus of elasticity (Eusw) was measured by ultrasonic technique, for predicting the flexural properties of different grade lumbers. The results showed that Eosw was larger than the static MOE. The relationship between Eusw and static MOE was significant at 0.01 level, and the determination coefficients (R2) of the four grade lumbers followed the sequence as R^2No.2 (0.616)〉 R^2ss (0.567)〉 R^2No1 (0.366)〉 R^2No.3 (0.137). The R^2 of Fusw and MOR were lower than that of the Etru and MOR for each grade. The Eusw of all the grade lumbers, except No.3-grade, had significant correlation with the static MOE and MOR, thus the bending strengthof those grade lumbers can be estimated by the E The Etru valuesof four grade lumbers followed a sequence as No.2-grade (10.701 GPa) 〉 SS-grade (10.359 GPa) 〉 No.l-grade (9.840 GPa) 〉 No.3-grade (9.554 GPa). For the same grade dimension lumber, its Eusw value was larger than static MOE. Mean values of MOR for four grade lumbers follow a sequence as No.2-grade (48.67 MPa) 〉 SS-grade (48.16 MPa) 〉 No.3-grade (46.55 MPa) 〉 No. 1-grade (43.39MPa). 展开更多
关键词 Dimension lumber Lumber grade Ultrasonic technique Dynamic modulus of elasticity Static modulus of elasticity Modulus of rupture
下载PDF
Clinical Value of Ultrosound in the Diagnosis of Testicular Tumor
15
作者 罗冬喜 杨为民 +3 位作者 叶章群 刘继红 孟磊 周四维 《The Chinese-German Journal of Clinical Oncology》 CAS 2003年第4期231-233,253,共4页
Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography... Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography (B-ultrasound and color Doppler flow imaging) was performed on 37 cases. One case was misdiagnosed. Surgical management was carried out in 42 cases and postoperational radiation therapy or chemotherapy was performed. The 1–5 year postoperative survival rate was totally 100%.Conclusion: B-ultrasound, especially color Doppler flow imaging, with the advantages of noninvasiveness and inexpensiveness was most useful and should be firstly employed in diagnosing the testicular tumor. The favorable prognosis can be obtained if an early diagnosis is made and the early treatment is performed. Key words testicular tumor - B-ultrasound - color Doppler flow imaging 展开更多
关键词 testicular tumor B-ULTRASOUND color Doppler flow imaging
下载PDF
Mass-forming pancreatitis: Value of contrast-enhanced ultrasonography 被引量:29
16
作者 Mirko D'Onofrio Giulia Zamboni +4 位作者 Alessia Tognolini Roberto Malagò Niccolò Faccioli Luca Frulloni Roberto Pozzi Mucelli 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第26期4181-4184,共4页
AIM: To assess the utility of contrast-enhanced ultrasonography (CEUS) with a second-generation contrast medium in the differential diagnosis between mass-forming pancreatitis and pancreatic carcinoma. METHODS: Fr... AIM: To assess the utility of contrast-enhanced ultrasonography (CEUS) with a second-generation contrast medium in the differential diagnosis between mass-forming pancreatitis and pancreatic carcinoma. METHODS: From our radio-pathology database, we retrieved all the patients affected by mass-forming pancreatitis or pancreatic carcinoma who underwent CEUS. We evaluated the results of CEUS in the study of the 173 pancreatic masses considering the possibilities of a differential diagnosis between mass-forming pancreatitis and pancreatic tumor by identifying the "parenchymographic" enhancement during the dynamic phase of CEUS, which was considered diagnostic for mass-forming pancreatitis. RESULTS: At CEUS, 94% of the mass-forming pancreatitis showed intralesional parenchymography. CEUS allowed diagnosis of mass-forming pancreatitis with sensitivity of 88.6%, specificity of 97.8%, positive predictive value of 91.2%, negative predictive value of 97.1%, and overall accuracy of 96%. CEUS significantly increased the diagnostic confidence in the differential diagnosis between mass-forming pancreatitis and pancreatic carcinoma, with receiver operating characteristic curve areas from 0.557 (P = 0.1608) for baseline US to 0.956 (P 〈 0.0001) for CEUS. CONCLUSION: CEUS allowed diagnosis of massforming pancreatitis with diagnostic accuracy of 96%. CEUS significantly increases the diagnostic confidence with respect to basal US in discerning mass-forming pancreatitis from pancreatic neoplasm. 展开更多
关键词 Contrast-enhanced ultrasonography PANCREATITIS Pancreatic neoplasm Mass-forming pancreatitis
下载PDF
Usefulness of endoscopic ultrasonography in preoperative TNM staging of gastric cancer 被引量:88
17
作者 Tumur Tsendsuren Sun-Ming Jun Xu-Hui Mian 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第1期43-47,共5页
AIM: To evaluate the value of endoscopic ultrasono- graphy (EUS) in the preoperative TNM staging of gastric cancer. METHODS : Forty-one patients with gastric cancer (12 early stage and 29 advanced stage) proved ... AIM: To evaluate the value of endoscopic ultrasono- graphy (EUS) in the preoperative TNM staging of gastric cancer. METHODS : Forty-one patients with gastric cancer (12 early stage and 29 advanced stage) proved by esophagogastroduodenoscopy and biopsies preoperatively evaluated with EUS according to TNM (1997) classification of International Union Contrele Cancer (UICC). Pentax EG-3630U/Hitachi EUB-525 echo endoscope with real-time ultrasound imaging linear scanning transducers (7.5 and 5.0 MHz) and Doppler information was used in the current study. EUS staging procedures for tumor depth of invasion (T stage) were performed according to the widely accepted five-layer structure of the gastric wall. All patients underwent surgery. Diagnostic accuracy of EUS for TNM staging of gastric cancer was determined by comparing preoperative EUS with subsequent postoperative histopathologic findings. RESULTS: The overall diagnostic accuracy of EUS in preoperative determination of cancer depth of invasion was 68.3% (41/28) and 83.3% (12/10), 60% (20/12), 100% (5/5), 25% (4/1) for T1, T2, T3, and T4, respectively. The rates for overstaging and understaging were 24.4% (41110), and 7.3% (4113), respectively. EUS tended to overstage T criteria, and main reasons for overstaging were thickening of the gastric wall due to perifocal inflammatory change, and absence of serosal layer in certain areas of the stomach. The diagnostic accuracy of metastatic lymph node involvement or N staging of EUS was 100% (17/17) for NO and 41.7% (24/10) for N+, respectively, and 66% (41127) overall.Misdiagnosing of the metastatic lymph nodes was related to the difficulty of distinguishing inflammatory lymph nodes from malignant lymph nodes, which imitate similar echo features. Predominant location and distribution of tumors in the stomach were in the antrum (20 patients), and the lesser curvature (17 patients), respectively. Three cases were found as surgically unresectable (T4 N+), and included as being correctly diagnosed by EUS. CONCLUSION: EUS is a useful diagnostic method for preoperative staging of gastric cancer for T and N criteria. However, EUS evaluation of malignant lymph nodes is still unsatisfactory. 展开更多
关键词 Endoscopic ultrasonography Preoperative staging Gastric cancer
下载PDF
Why,who and how should perform liver biopsy in chronic liver diseases 被引量:12
18
作者 Ioan Sporea Alina Popescu Roxana Sirli 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第21期3396-3402,共7页
Chronic viral hepatitis is a common disease in the general population.During chronic hepatitis,the prognosis and clinical management are highly dependent on the extent of liver fibrosis.The fibrosis evaluation can be ... Chronic viral hepatitis is a common disease in the general population.During chronic hepatitis,the prognosis and clinical management are highly dependent on the extent of liver fibrosis.The fibrosis evaluation can be performed by FibroTest(using serological markers),by Elastography or FibroScan(a noninvasive percutaneous technique using the elastic properties of the hepatic tissue) and by liver biopsy(LB),considered to be the "gold standard".Currently,there are three techniques for performing LB:percutaneous,transjugular and laparoscopic.The percutaneous LB can be performed blind,ultrasound(US) guided or US assisted.There are two main categories of specialists who perform LB:gastroenterologists(hepatologists) and radiologists,and the specialty of the individual who performs the LB determines if the LB is performed under ultrasound guidance or not.There are two types of biopsy needles used for LB:cutting needles(Tru-Cut,Vim-Silverman) and suction needles(Menghini,Klatzkin,Jamshidi).The rate of major complications after percutaneous LB ranges from 0.09% to 2.3%,but the echo-guided percutaneous liver biopsy is a safe method for the diagnosis of chronic diffuse hepatitis(cost-effective as compared to blind biopsy) and the rate of complications seems to be related to the experience of the physician and the type of the needle used(Menghini type needle seems to be safer).Maybe,in a few years we will use non-invasive markers of fibrosis,but at this time,most authorities in the field consider that the LB is useful and necessary for the evaluation of chronic hepatopathies,despite the fact that it is not a perfect test. 展开更多
关键词 Chronic hepatitis Liver biopsy FIBROSIS Ultrasound guidance
下载PDF
How good is endoscopic ultrasound for TNM staging of gastric cancers? A meta-analysis and systematic review 被引量:34
19
作者 Srinivas Reddy Puli Jyotsna Batapati Krishna Reddy +2 位作者 Matthew L Bechtold Mainor R Antillon Jamal A Ibdah 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第25期4011-4019,共9页
AIM: To evaluate the accuracy of endoscopic ultrasound (EUS) for staging of gastric cancers. METHODS: Only EUS studies confirmed by surgery were selected. Only studies from which a 2 × 2 table could be constructe... AIM: To evaluate the accuracy of endoscopic ultrasound (EUS) for staging of gastric cancers. METHODS: Only EUS studies confirmed by surgery were selected. Only studies from which a 2 × 2 table could be constructed for true positive, false negative, false positive and true negative values were included. Articles were searched in Medline, Pubmed, Ovid journals, Cumulative index for nursing & allied health literature, International pharmaceutical abstracts, old Medline, Medline nonindexed citations, and Cochrane control trial registry. Two reviewers independently searched and extracted data. The differences were resolved by mutual agreement. 2 × 2 tables were constructed with the data extracted from each study. Meta-analysis for the accuracy of EUS was analyzed by calculating pooled estimates of sensitivity, specifi city, likelihood ratios, and diagnostic odds ratio. Pooling was conducted by both the Mantel-Haenszel method (fi xed effects model) and DerSimonian Laird method (random effects model). The heterogeneity of studies was tested using Cochran's Q test based upon inverse variance weights. RESULTS: Initial search identified 1620 reference articles and of these, 376 relevant articles were selected and reviewed. Twenty-two studies (n = 1896) which met the inclusion criteria were included in this analysis. Pooled sensitivity of T1 was 88.1% (95% CI: 84.5-91.1) and T2 was 82.3% (95% CI: 78.2-86.0). For T3, pooled sensitivity was 89.7% (95% CI: 87.1-92.0). T4 hada pooled sensitivity of 99.2% (95% CI: 97.1-99.9). For nodal staging, the pooled sensitivity for N1 was 58.2% (95% CI: 53.5-62.8) and N2 was 64.9% (95% CI: 60.8-68.8). Pooled sensitivity to diagnose distant metastasis was 73.2% (95% CI: 63.2-81.7). The P for chi-squared heterogeneity for all the pooled accuracy estimates was > 0.10. CONCLUSION: EUS results are more accurate with advanced disease than early disease. If EUS diagnoses advanced disease, such as T4 disease, the patient is 500 times more likely to have true anatomic stage of T4 disease. 展开更多
关键词 Gastric cancer STAGING META-ANALYSIS Endoscopic ultrasound
下载PDF
Assessment of metastatic liver disease in patients with primary extrahepatic tumors by contrast-enhanced sonography versus CT and MRI 被引量:39
20
作者 Christoph F Dietrich Wolfgang Kratzer +10 位作者 Deike Strobel Etienne Danse Robert Fessl Alfred Bunk Udo Vossas Karlheinz Hauenstein Wilhelm Koch Wolfgang Blank Matthijs Oudkerk Dietbert Hahn Christian Greis 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第11期1699-1705,共7页
AIM: To evaluate contrast-enhanced ultrasonography (CEUS) using SonoVue in the detection of liver metastases in patients with known extrahepatic primary tumors versus the combined gold standard comprising CT, MRI a... AIM: To evaluate contrast-enhanced ultrasonography (CEUS) using SonoVue in the detection of liver metastases in patients with known extrahepatic primary tumors versus the combined gold standard comprising CT, MRI and clinical/histological data. METHODS: It is an international multicenter study, and there were 12 centres and 125 patients (64 males, 61 females, aged 59 ± 11 years) involved, with 102 patients per protocol. Primary tumors were colorectal in 35%, breast in 27%, pancreatic in 17% and others in 21%. CEUS using SonoVue was employed with a Iow-mechanical-index technique and contrast-specific software using Siemens Elegra, Philips HDI 5000 and Acuson Sequoia; continuous scanning for at least five minutes. RESULTS: CEUS with SonoVue increased significantly the number of focal liver lesions detected versus unenhanced sonography. In 31.4% of the patients, more lesions were found after contrast enhancement. The total numbers of lesions detected were comparable with CEUS (55), triple-phase spiral CT (61) and HRI with a liverspecific contrast agent (53). Accuracy of detection of metastatic disease (i.e. at least one metastatic lesion) was significantly higher for CEUS (91.2%) than for unenhanced sonography (81.4%) and was similar to that of triple-phase spiral CT (89.2 %). In 53 patients whose CEUS examination was negative, a follow-up examination 3-6 months later confirmed the absence of metastatic lesions in 50 patients (94.4%). CONCLUSION: CEUS is proved to be reliable in the detection of liver metastases in patients with known extrahepatic primary tumors and suspected liver lesions. 展开更多
关键词 CT MRI METASTASIS Detection SONOVUE
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部