Polyvinylidenefluoride (PVDF) hollow fiber ultrafiltration membrane is frequently employed in water treatment. However, the fouling of ultrafiltration membranes affects the economic effectiveness of such process sig...Polyvinylidenefluoride (PVDF) hollow fiber ultrafiltration membrane is frequently employed in water treatment. However, the fouling of ultrafiltration membranes affects the economic effectiveness of such process significantly. The ultrasound generated by flat plate transducer (UFPT) was used to clean the polluted PVDF ultrafiltration membrane with 2 g·L^-1 of citric acid aqueous solution in our study. The effects of UFPT intensity on the membrane surface were studied. The new membrane was easy to be polluted by the saturated CaCl2 solution. A synergistic effect of UFPT and 2 g·L^-1 citric acid aqueous solution could remove the foul of the membrane, and its flux could be recovered about 81%. The flux recovery of old membrane polluted was increased to 73.2% after 7 h soaking in citric acid aqueous solution, but its flux recovery without soaking was only increased to 56.2%.展开更多
Polysulfone(PS)hollow-fiber ultrafiltration membrane was characterized combined with flux and streaming potential in single electrolyte solutions.The effects of trans-membrane pressure,electrolyte concentration,ion va...Polysulfone(PS)hollow-fiber ultrafiltration membrane was characterized combined with flux and streaming potential in single electrolyte solutions.The effects of trans-membrane pressure,electrolyte concentration,ion valence and pH value of electrolyte solution on the streaming potential(SP)of the membrane were investigated.The zeta potential and surface charge density of the membrane were calculated on the basis of Helmholtz-Smoluchowski equation and Gouy-Chapmann theory.The results indicate that the valence and concentration of cation have a greater influence on the SP and surface charge density of PS membrane than those of anion,and the pH value of electrolyte solution has great effects on the SP and zeta potential of the membrane surface. Both the absolute value of the streaming potential and water flux of the adsorbed membrane decrease,compared with those of the clean membrane.The streaming potential and flux of the cleaned membrane can be completely recovered by cleaning with the mass fraction of 0.8%EDTA at pH=10.展开更多
文摘Polyvinylidenefluoride (PVDF) hollow fiber ultrafiltration membrane is frequently employed in water treatment. However, the fouling of ultrafiltration membranes affects the economic effectiveness of such process significantly. The ultrasound generated by flat plate transducer (UFPT) was used to clean the polluted PVDF ultrafiltration membrane with 2 g·L^-1 of citric acid aqueous solution in our study. The effects of UFPT intensity on the membrane surface were studied. The new membrane was easy to be polluted by the saturated CaCl2 solution. A synergistic effect of UFPT and 2 g·L^-1 citric acid aqueous solution could remove the foul of the membrane, and its flux could be recovered about 81%. The flux recovery of old membrane polluted was increased to 73.2% after 7 h soaking in citric acid aqueous solution, but its flux recovery without soaking was only increased to 56.2%.
基金Project(20776161)supported by the National Natural Science Foundation of China
文摘Polysulfone(PS)hollow-fiber ultrafiltration membrane was characterized combined with flux and streaming potential in single electrolyte solutions.The effects of trans-membrane pressure,electrolyte concentration,ion valence and pH value of electrolyte solution on the streaming potential(SP)of the membrane were investigated.The zeta potential and surface charge density of the membrane were calculated on the basis of Helmholtz-Smoluchowski equation and Gouy-Chapmann theory.The results indicate that the valence and concentration of cation have a greater influence on the SP and surface charge density of PS membrane than those of anion,and the pH value of electrolyte solution has great effects on the SP and zeta potential of the membrane surface. Both the absolute value of the streaming potential and water flux of the adsorbed membrane decrease,compared with those of the clean membrane.The streaming potential and flux of the cleaned membrane can be completely recovered by cleaning with the mass fraction of 0.8%EDTA at pH=10.