Temperature, as an important feature of hydroponic nutrient solution, is closely related to dissolved oxygen content of nutrient solution and growth status of plant roots. How to precisely adjust the temperature of nu...Temperature, as an important feature of hydroponic nutrient solution, is closely related to dissolved oxygen content of nutrient solution and growth status of plant roots. How to precisely adjust the temperature of nutrient solution is the key to obtain high quality and high yield of hydroponic vegetables over summer. With Lactuca sativa vat. crispa 'Luosheng No.3' as the test material, the effect of chiller cooling technology on the temperature of nutrient solution, as well as on the yield and quality of Luosheng No.3, in over-summer hydroponic cultivation was studied. The results showed that the chiller cooling technology controlled the nutrient solution temperature in a reasonable range ((20 ± 1)℃) and promoted the growth and dry matter accumulation of Luosheng No.3, instead of affecting the quality. In short, the chiller cooling technology is applicable to the temperature regulation of nutrient solu- tion in hydroponics over summer.展开更多
Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conduct...Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conductor self-damping,and the damper dissipated power. Meanwhile,we built a theoretical mechanical model of β wire dampers and derived energy dissipation calculation formulae. This permits the vibration energy dissipated by β wire dampers can be considered in the energy balance method. Then,we developed a computer program based on the improved energy balance method using Matlab,and analyzed UHV long span ground wires of the Han River long span project in P. R. China. The results show that the combination of β wire dampers and Stockbridge dampers can reduce vibration of UHV long span transmission lines,which provides a reference for research and construction of UHV engineering projects.展开更多
基金Supported by Science and Technology Innovative Leading Fund of Ningxia Academy of Agriculture and Forestry Sciences(NKYZ-16-1101)~~
文摘Temperature, as an important feature of hydroponic nutrient solution, is closely related to dissolved oxygen content of nutrient solution and growth status of plant roots. How to precisely adjust the temperature of nutrient solution is the key to obtain high quality and high yield of hydroponic vegetables over summer. With Lactuca sativa vat. crispa 'Luosheng No.3' as the test material, the effect of chiller cooling technology on the temperature of nutrient solution, as well as on the yield and quality of Luosheng No.3, in over-summer hydroponic cultivation was studied. The results showed that the chiller cooling technology controlled the nutrient solution temperature in a reasonable range ((20 ± 1)℃) and promoted the growth and dry matter accumulation of Luosheng No.3, instead of affecting the quality. In short, the chiller cooling technology is applicable to the temperature regulation of nutrient solu- tion in hydroponics over summer.
基金Funded by the Natural Science Foundation of China (No. 50878093).
文摘Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conductor self-damping,and the damper dissipated power. Meanwhile,we built a theoretical mechanical model of β wire dampers and derived energy dissipation calculation formulae. This permits the vibration energy dissipated by β wire dampers can be considered in the energy balance method. Then,we developed a computer program based on the improved energy balance method using Matlab,and analyzed UHV long span ground wires of the Han River long span project in P. R. China. The results show that the combination of β wire dampers and Stockbridge dampers can reduce vibration of UHV long span transmission lines,which provides a reference for research and construction of UHV engineering projects.