Recently, the community analysis has seen enormous research advancements in the field of social networks. A large amount of the current studies put forward different models and algorithms about most influential people...Recently, the community analysis has seen enormous research advancements in the field of social networks. A large amount of the current studies put forward different models and algorithms about most influential people. However, there is little work to shed light on how to rank communities while considering their levels that are determined by the quality of their published contents. In this paper, we propose solution for measuring the influence of communities and ranking them by considering joint weight composed of internal and external influence of communities. To address this issue, we design a novel algorithm called Com Rank: a modification of Page Rank, which considers the joint weight in order to identify impact of each community and ranking them. We use real-world data trace in citation network and perform extensive experiments to evaluate our proposed algorithm. The comparative results depict significant improvements by our algorithm in community ranking due to the inclusion of proposed weighting feature.展开更多
Quintessence field is a widely-studied candidate of dark energy. There is "tracker solution" in quintessence models, in which evolution of the field φ at present times is not sensitive to its initial conditions. Wh...Quintessence field is a widely-studied candidate of dark energy. There is "tracker solution" in quintessence models, in which evolution of the field φ at present times is not sensitive to its initial conditions. When the energy density of dark energy is negleetable (Ωφ 〈〈 1), evolution of the tracker solution can be well analysed from "tracker equation". In this paper, we try to study evolution of the quintessence field from "full tracker equation", which is valid for all spans of Ωφ. We get stable fixed points of we and wφ (noted as wφ and Ωφ) from the "full tracker equation", i.e., we and ωφ will always approach ωφ and Ωφ respectively. Since wφ and Ωφ are analytic functions of φ, analytic relation of φ can be obtained, which is a good approximation for the we φ relation and can be obtained for the most type of quintessence potentials. By using this approximation, we find that inequalities ωφ 〈 we and 〈ωφ are statisfied if the we (or ωφ) decreases with time. In this way, the potentiai U(φ) can be constrained directly from observations, by no need of solving the equations of motion numerically.展开更多
This paper presents the estimation of three-dimensional volumetric errors of a machining center by using a tracking interferometer. A tracking interferometer is a laser interferometer with the mechanism to steer the l...This paper presents the estimation of three-dimensional volumetric errors of a machining center by using a tracking interferometer. A tracking interferometer is a laser interferometer with the mechanism to steer the laser direction to follow a target retroreflector. Based on the triangulation principle, the three-dimensional position of the target can be estimated from measured laser displacements. Its capability to measure three-dimensional positioning errors for arbitrary trajectories is important for the indirect measurement of the machine's kinematic model. This paper presents experimental investigation of the estimation accuracy of the multilateration-based measurement by a tracking interferometer. A tracking interferometer developed by a part of the authors is used in experiments. In the present experiment, the measured volume of target positions was 100 mm × 100 mm × 100 mm. The estimation accuracy of targets within this volume was not sufficiently high compared to the positioning error of the measured machine tool. The results of the experiment and simulation show that the estimation uncertainty is dependent on tracking interferometer locations relative to target locations. Error sensitivity analysis shows that wider distribution of tracker positions in XY improves the estimation accuracy.展开更多
Light pen coordinate measuring system(LPCMS)is a kind of portable coordinate measuring technique based on vision metrology.In classical LPCMS,the measuring range is limited to the camera’s field of view.To overcome t...Light pen coordinate measuring system(LPCMS)is a kind of portable coordinate measuring technique based on vision metrology.In classical LPCMS,the measuring range is limited to the camera’s field of view.To overcome this defect,a new LPCMS is designed in this paper to fulfil whole space coordinate measurement.The camera is installed on a turntable instead of a tripod,so that the camera can rotate to track the movement of the light pen.The new system can be applied to large scale onsite measurement,and therefore it notably extends the application of LPCMS.To guarantee the accuracy of the new system,a method to calibrate the parameters of the tracking turntable is also proposed.Fixing the light pen at a stationary position,and changing the azimuth angles of the turntable’s two shafts,so that the camera can capture the images of the light pen from different view angles.According to the invariant spatial relationship between the camera and the pedestal of the tracking turntable,a system of nonlinear equations can be established to solve the parameters of the turntable.Experimental results show that the whole space coordinate measuring accuracy of the new system can reach 0.25 mm within 10 m.It can be concluded that the newly designed system can significantly expand the measuring range of LPCMS without losing too much accuracy.展开更多
This study covers the problem that most products become less competitive especially in the decline stages of their life cycle as most companies do not put adequate emphasis on using networked manufacturing systems in ...This study covers the problem that most products become less competitive especially in the decline stages of their life cycle as most companies do not put adequate emphasis on using networked manufacturing systems in the entire life cycle of a single product. The study employed a non-experimental approach to collect data. The research paper relied on secondary data for further analysis. The secondary sources used in this paper have been referenced progressively in the entire paper. The paper found that most companies are often faced with the challenge of coping with quality management in a product life cycle. Also, it found that networked manufacturing systems have provided a new paradigm for real-time monitoring and control at various life stages. The paper is divided as following parts: section 1 is about the background and problem statement. Section 2 comes through literature review including theoretical & empirical review. Section 3 explains the procedures and methods that were used in carrying out the study. It explains how data collection was carried out and how data analysis was performed. Section 4 is about the results the paper found. Section 5 is a discussion of the results presented.展开更多
During the non-landing measuring of vehicle mounted theodolite, especially under high-speed tracking measurement, the misalignment of theodolite's center of mass and spindle etc. will cause high-frequency vibratio...During the non-landing measuring of vehicle mounted theodolite, especially under high-speed tracking measurement, the misalignment of theodolite's center of mass and spindle etc. will cause high-frequency vibration of theodolite platform, increase the observation error of targets and even unbelievable results. In this paper, a correction method of non-landing measuring of theodolite based on static datum conversion is presented, which can effectively improve the observation accuracy of theodolite. The CCD camera is fixed to the theodolite platform to calculate the gesture shaking quantity of theodolite platform in geodetic coordinate system through the real time imaging of static datum. The observation results of theodolite are corrected by using such shaking quantity. The experiment shows that the correction accuracy exceeds 10 s of arc. The intrinsic parameter calibration technology of camera based on stellar angular distance and absolute conic put forward in this paper can prevent the estimated error of extrinsic parameters influencing the intrinsic parameter calibration and improve the intrinsic parameter calibration accuracy; the static datum conversion technology can reduce the influence of installation error of camera and theodolite platform on gesture measuring of the platform. The simulation experiment shows that when the shaking range of the platform is less than 30 min of arc, the influence of the three-axis installation error of camera within 3deg on the accuracy of correction results is less than 8 s of arc. The method in this paper can be extended to and used in the field of gesture shaking measuring and micro-structure deformation of various unstable platforms, therefore it is of important theoretical research significance and has wide engineering application prospect.展开更多
基金supported in part by the following funding agencies of China:National Natural Science Foundation under Grant 61170274, 61602050 and U1534201
文摘Recently, the community analysis has seen enormous research advancements in the field of social networks. A large amount of the current studies put forward different models and algorithms about most influential people. However, there is little work to shed light on how to rank communities while considering their levels that are determined by the quality of their published contents. In this paper, we propose solution for measuring the influence of communities and ranking them by considering joint weight composed of internal and external influence of communities. To address this issue, we design a novel algorithm called Com Rank: a modification of Page Rank, which considers the joint weight in order to identify impact of each community and ranking them. We use real-world data trace in citation network and perform extensive experiments to evaluate our proposed algorithm. The comparative results depict significant improvements by our algorithm in community ranking due to the inclusion of proposed weighting feature.
基金Supported in part by the National Science Foundation of China under Grant No.10425525
文摘Quintessence field is a widely-studied candidate of dark energy. There is "tracker solution" in quintessence models, in which evolution of the field φ at present times is not sensitive to its initial conditions. When the energy density of dark energy is negleetable (Ωφ 〈〈 1), evolution of the tracker solution can be well analysed from "tracker equation". In this paper, we try to study evolution of the quintessence field from "full tracker equation", which is valid for all spans of Ωφ. We get stable fixed points of we and wφ (noted as wφ and Ωφ) from the "full tracker equation", i.e., we and ωφ will always approach ωφ and Ωφ respectively. Since wφ and Ωφ are analytic functions of φ, analytic relation of φ can be obtained, which is a good approximation for the we φ relation and can be obtained for the most type of quintessence potentials. By using this approximation, we find that inequalities ωφ 〈 we and 〈ωφ are statisfied if the we (or ωφ) decreases with time. In this way, the potentiai U(φ) can be constrained directly from observations, by no need of solving the equations of motion numerically.
文摘This paper presents the estimation of three-dimensional volumetric errors of a machining center by using a tracking interferometer. A tracking interferometer is a laser interferometer with the mechanism to steer the laser direction to follow a target retroreflector. Based on the triangulation principle, the three-dimensional position of the target can be estimated from measured laser displacements. Its capability to measure three-dimensional positioning errors for arbitrary trajectories is important for the indirect measurement of the machine's kinematic model. This paper presents experimental investigation of the estimation accuracy of the multilateration-based measurement by a tracking interferometer. A tracking interferometer developed by a part of the authors is used in experiments. In the present experiment, the measured volume of target positions was 100 mm × 100 mm × 100 mm. The estimation accuracy of targets within this volume was not sufficiently high compared to the positioning error of the measured machine tool. The results of the experiment and simulation show that the estimation uncertainty is dependent on tracking interferometer locations relative to target locations. Error sensitivity analysis shows that wider distribution of tracker positions in XY improves the estimation accuracy.
基金State Administration of Science,Technology and Industry for the National Defense(No.JSJL2014206B001)。
文摘Light pen coordinate measuring system(LPCMS)is a kind of portable coordinate measuring technique based on vision metrology.In classical LPCMS,the measuring range is limited to the camera’s field of view.To overcome this defect,a new LPCMS is designed in this paper to fulfil whole space coordinate measurement.The camera is installed on a turntable instead of a tripod,so that the camera can rotate to track the movement of the light pen.The new system can be applied to large scale onsite measurement,and therefore it notably extends the application of LPCMS.To guarantee the accuracy of the new system,a method to calibrate the parameters of the tracking turntable is also proposed.Fixing the light pen at a stationary position,and changing the azimuth angles of the turntable’s two shafts,so that the camera can capture the images of the light pen from different view angles.According to the invariant spatial relationship between the camera and the pedestal of the tracking turntable,a system of nonlinear equations can be established to solve the parameters of the turntable.Experimental results show that the whole space coordinate measuring accuracy of the new system can reach 0.25 mm within 10 m.It can be concluded that the newly designed system can significantly expand the measuring range of LPCMS without losing too much accuracy.
文摘This study covers the problem that most products become less competitive especially in the decline stages of their life cycle as most companies do not put adequate emphasis on using networked manufacturing systems in the entire life cycle of a single product. The study employed a non-experimental approach to collect data. The research paper relied on secondary data for further analysis. The secondary sources used in this paper have been referenced progressively in the entire paper. The paper found that most companies are often faced with the challenge of coping with quality management in a product life cycle. Also, it found that networked manufacturing systems have provided a new paradigm for real-time monitoring and control at various life stages. The paper is divided as following parts: section 1 is about the background and problem statement. Section 2 comes through literature review including theoretical & empirical review. Section 3 explains the procedures and methods that were used in carrying out the study. It explains how data collection was carried out and how data analysis was performed. Section 4 is about the results the paper found. Section 5 is a discussion of the results presented.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11072263 and 11272347)Program for New Century Talents in University
文摘During the non-landing measuring of vehicle mounted theodolite, especially under high-speed tracking measurement, the misalignment of theodolite's center of mass and spindle etc. will cause high-frequency vibration of theodolite platform, increase the observation error of targets and even unbelievable results. In this paper, a correction method of non-landing measuring of theodolite based on static datum conversion is presented, which can effectively improve the observation accuracy of theodolite. The CCD camera is fixed to the theodolite platform to calculate the gesture shaking quantity of theodolite platform in geodetic coordinate system through the real time imaging of static datum. The observation results of theodolite are corrected by using such shaking quantity. The experiment shows that the correction accuracy exceeds 10 s of arc. The intrinsic parameter calibration technology of camera based on stellar angular distance and absolute conic put forward in this paper can prevent the estimated error of extrinsic parameters influencing the intrinsic parameter calibration and improve the intrinsic parameter calibration accuracy; the static datum conversion technology can reduce the influence of installation error of camera and theodolite platform on gesture measuring of the platform. The simulation experiment shows that when the shaking range of the platform is less than 30 min of arc, the influence of the three-axis installation error of camera within 3deg on the accuracy of correction results is less than 8 s of arc. The method in this paper can be extended to and used in the field of gesture shaking measuring and micro-structure deformation of various unstable platforms, therefore it is of important theoretical research significance and has wide engineering application prospect.