期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
MODEL REFERENCE ADAPTIVE CONTROL BASED ON NONLINEAR COMPENSATION FOR TURBOFAN ENGINE 被引量:4
1
作者 潘慕绚 黄金泉 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2012年第3期215-221,共7页
The design of a turbofan rotor speed control system, using model reference adaptive control(MRAC) method with input and output measurements, is discussed for the purpose of practical application. The nonlinear compe... The design of a turbofan rotor speed control system, using model reference adaptive control(MRAC) method with input and output measurements, is discussed for the purpose of practical application. The nonlinear compensator based on functional link neural network is used to deal with the engine nonlinearity and the hardware-in-loop simulation is also developed. The results show that the nonlinear MRAC controller has the adequate performance of compensating and adapting nonlinearity arising from the change of engine state or working environment. Such feature demonstrates potential practical applications of MRAC for aeroengine control system. 展开更多
关键词 turbofan engin model reference adaptive control(MRAC) functional link neural network (FLNN) hardware-in-loop(HIL) simulation
下载PDF
国产自动间隙调整臂投入市场
2
《汽车零部件世界》 2005年第1期27-27,共1页
目前,重庆卡福制动转向有限公司副总经理马国华向记者透露,该公刮自行研发生产的自动间隙调整臂通过相关部门的检验测试,开始投放市场。这表明我国载重车的自动问隙调整臂产品告别被国外垄断的局面。
关键词 中国 自动间隙调整臂 汽车市场 汽车制动 路试实验
下载PDF
统一润滑油获得山东凯马汽车用油认可
3
《汽车维修与保养》 2005年第9期65-65,共1页
关键词 “统一”润滑油 山东凯马汽车公司 用油认可证书 自卸汽车 载货汽车 路试实验
下载PDF
An Experience of On-site PD Testing for Condition Monitoring of an 11 kV PILC Cable Insulation System
4
作者 Xiaosheng Peng Chengke Zhou Xiaodi Song 《Journal of Energy and Power Engineering》 2012年第1期140-145,共6页
A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to fur... A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to further diagnose and locate the potential problem of the cable system. This paper presents the experience of the present authors carrying out the cable test. Following a brief introduction to the experiment equipments and physical connections, the paper analyses the data collected from the testing, including PD pulse shape analysis, frequency spectrum analysis and phase resolved PD pattern analysis. Associated with PD propagation direction identification, PD source diagnosis and localisation was made. Four different types of sensors, which were adapted during the testing, are shown to have different frequency bandwidths and performed differently. Aider comparing the parameters of the sensor and the PD signals detected by individual sensor, optimal PD monitoring bandwidth for cable system is suggested. 展开更多
关键词 PD identification on-site testing PILC cable switchgear box insulation defect PD propagation direction sensor.
下载PDF
Lightning Induced Surge on the Distribution Lines in the House near by the Lightning Point
5
作者 Aiko Takahara Ryoji Oshiro Eiji Kaneko 《Journal of Energy and Power Engineering》 2012年第5期840-844,共5页
Recently, a lightning surge is recognized as one of the biggest risks to the society. If the surges induced by lightning invade into low voltage distribution lines, there might be a possibility of giving some severe d... Recently, a lightning surge is recognized as one of the biggest risks to the society. If the surges induced by lightning invade into low voltage distribution lines, there might be a possibility of giving some severe damages to the systems. Therefore, it is necessary to examine these induced phenomena. FDTD (finite difference time domain) method which treats objects as three-dimensional solid circuits is applied to analyze these induced phenomena. VSTL (Virtual Surge Test Lab.) is the surge analysis simulation program using FDTD method. In this paper, the lightning induced phenomena on the low voltage distribution line in the house are analyzed by using VSTL. In this paper, investigation results about induced surge when a lightning struck the point nearby the house, and about a suppressing effect of surges by comparing the results of analysis with and without SPD (surge protective device) are shown. As a result, it is confirmed that SPD is effective for suppressing lightning surge. 展开更多
关键词 Lightning surge induced phenomena FDTD method distribution line VSTL.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部