An efficient cycle slip detection method is proposed for high precision positioning and navigation results with global positioning system (GPS),which is based on the assumption of a high sampling interval, measureme...An efficient cycle slip detection method is proposed for high precision positioning and navigation results with global positioning system (GPS),which is based on the assumption of a high sampling interval, measurement errors are so small that they can be ignored in the temporal single difference observables. And ambiguities are ordinarily equal to zero,but could be the number of cycles that have "slipped" if loss-of-lock has occurred.Therefore,cycle slips are estimated as parameters of time-relative positioning observation equations.Because the temporal single difference observables are taken at different epochs and different stations with a single GPS receiver,if time-relative positioning observation equations are linearized as that of conventional relative positioning,the design matrix will be rank defective.To obtain a stable linearization scheme,time-relative positioning observation equations are further analyzed,and the concept of virtual measurement is applied.A sample of data collected on a vehicle test shows that a cycle slip detection approach based on time-relative positioning theory can detect slips at the value of one cycle.The results also indicate if two satellites are so near to each other that they have the same equivalent to satellite-receiver geometry,cycle slip detection will be difficult and may get wrong results.Cycle slips of different satellites also affect detection by satellite-receiver geometry.展开更多
In this paper, a novel strategy for numerically evaluating the dark-solitonjitter in optical communications is proposed. It is further tested to be consistent with the famousthreshold-value-oriented method for rather ...In this paper, a novel strategy for numerically evaluating the dark-solitonjitter in optical communications is proposed. It is further tested to be consistent with the famousthreshold-value-oriented method for rather larger distances. Then our method is used to calculatethe dark-soliton jitter within arbitrary small distances. An excellent agreement is obtained withthe theoretical predictions based on the nonlinear Schrddinger equation. Our method is alsoapplicable to some more complicated systems such as the dissipative-dispersive system.展开更多
Objective: To assess the cerebral injury in on-pump beating-heart procedures under mild hypothermia in comparison with traditional on-pump arrested-heart procedures under moderate hypothermia. Methods: Forty patients,...Objective: To assess the cerebral injury in on-pump beating-heart procedures under mild hypothermia in comparison with traditional on-pump arrested-heart procedures under moderate hypothermia. Methods: Forty patients, 20 with congenital heart disease (CHD) and 20 of rheumatic heart disease (RHD) , were divided into 2 groups: Control group (group A, n =20) including 10 patients suffering from CHD as group Al and the left 10 from RHD as group A2; and experiment group (group B, n =20) which consisting of group B1 (10 with CHD) and group B2 (10 of RHD). The patients in group A underwent traditional arrested-heart procedures, and those in group B were operated on with beating-heart procedures. Arterial blood samples were collected at preoperation (time A) , 20 min after cardiopul-monary bypass (CPB) starting (time B) , 1 h after CPB (time C) and 24 h postoperation (time D) respectively. Plasma contents of neuron-specific enolase (NSE) and protein S-100b were measured with sensitive ELISA. All the patients received echoencephalography (EEG) before and 1 week after operation. Results: The plasma contents of protein S-lOOb were increased very significantly at time B, C and D in comparison with those at time A (P<0.01) , and that of patients in group Al was significantly higher than that in group B at time B (P < 0. 05 ). There was no significant difference at other time points. At time B, the plasma contents of NSE were significantly higher in group A than in group B, and in group Al and Bl than in group A2 and B2. What's more, at time B, the former fell back to their pre-operative levels, but the latter remained still higher levels than the preoperative ones ( P < 0.01). No significant difference was found in the abnormality rates of postoperative EEG between 2 groups. Conclusion: The perioperative plasma contents of NSE and protein S-100b are not significantly higher in group B than in group A. On-pump beating-heart procedures do not make more serious cerebral dysfunction than the traditional arrested-heart procedures.展开更多
Jockusch, Li and Yang showed that the Lown and Low1 r.e. degrees are not elementarily equivalent for n>1. We answer a question they raise by using the results of Nies, Shore and Slaman to show that the Lown and Low...Jockusch, Li and Yang showed that the Lown and Low1 r.e. degrees are not elementarily equivalent for n>1. We answer a question they raise by using the results of Nies, Shore and Slaman to show that the Lown and Lowm r.e. degrees are not elementarily equivalent for n > m > 1.展开更多
文摘An efficient cycle slip detection method is proposed for high precision positioning and navigation results with global positioning system (GPS),which is based on the assumption of a high sampling interval, measurement errors are so small that they can be ignored in the temporal single difference observables. And ambiguities are ordinarily equal to zero,but could be the number of cycles that have "slipped" if loss-of-lock has occurred.Therefore,cycle slips are estimated as parameters of time-relative positioning observation equations.Because the temporal single difference observables are taken at different epochs and different stations with a single GPS receiver,if time-relative positioning observation equations are linearized as that of conventional relative positioning,the design matrix will be rank defective.To obtain a stable linearization scheme,time-relative positioning observation equations are further analyzed,and the concept of virtual measurement is applied.A sample of data collected on a vehicle test shows that a cycle slip detection approach based on time-relative positioning theory can detect slips at the value of one cycle.The results also indicate if two satellites are so near to each other that they have the same equivalent to satellite-receiver geometry,cycle slip detection will be difficult and may get wrong results.Cycle slips of different satellites also affect detection by satellite-receiver geometry.
文摘In this paper, a novel strategy for numerically evaluating the dark-solitonjitter in optical communications is proposed. It is further tested to be consistent with the famousthreshold-value-oriented method for rather larger distances. Then our method is used to calculatethe dark-soliton jitter within arbitrary small distances. An excellent agreement is obtained withthe theoretical predictions based on the nonlinear Schrddinger equation. Our method is alsoapplicable to some more complicated systems such as the dissipative-dispersive system.
文摘Objective: To assess the cerebral injury in on-pump beating-heart procedures under mild hypothermia in comparison with traditional on-pump arrested-heart procedures under moderate hypothermia. Methods: Forty patients, 20 with congenital heart disease (CHD) and 20 of rheumatic heart disease (RHD) , were divided into 2 groups: Control group (group A, n =20) including 10 patients suffering from CHD as group Al and the left 10 from RHD as group A2; and experiment group (group B, n =20) which consisting of group B1 (10 with CHD) and group B2 (10 of RHD). The patients in group A underwent traditional arrested-heart procedures, and those in group B were operated on with beating-heart procedures. Arterial blood samples were collected at preoperation (time A) , 20 min after cardiopul-monary bypass (CPB) starting (time B) , 1 h after CPB (time C) and 24 h postoperation (time D) respectively. Plasma contents of neuron-specific enolase (NSE) and protein S-100b were measured with sensitive ELISA. All the patients received echoencephalography (EEG) before and 1 week after operation. Results: The plasma contents of protein S-lOOb were increased very significantly at time B, C and D in comparison with those at time A (P<0.01) , and that of patients in group Al was significantly higher than that in group B at time B (P < 0. 05 ). There was no significant difference at other time points. At time B, the plasma contents of NSE were significantly higher in group A than in group B, and in group Al and Bl than in group A2 and B2. What's more, at time B, the former fell back to their pre-operative levels, but the latter remained still higher levels than the preoperative ones ( P < 0.01). No significant difference was found in the abnormality rates of postoperative EEG between 2 groups. Conclusion: The perioperative plasma contents of NSE and protein S-100b are not significantly higher in group B than in group A. On-pump beating-heart procedures do not make more serious cerebral dysfunction than the traditional arrested-heart procedures.
文摘Jockusch, Li and Yang showed that the Lown and Low1 r.e. degrees are not elementarily equivalent for n>1. We answer a question they raise by using the results of Nies, Shore and Slaman to show that the Lown and Lowm r.e. degrees are not elementarily equivalent for n > m > 1.