A CMOS folding and interpolating analog-to-digital converter (ADC) for embedded application is described.The circuit is fully compatible with standard digital CMOS technology.A modified folding block implemented witho...A CMOS folding and interpolating analog-to-digital converter (ADC) for embedded application is described.The circuit is fully compatible with standard digital CMOS technology.A modified folding block implemented without resistor contributes to a small chip area.At the input stage,offset averaging reduces the input capacitance and the distributed track-and-hold circuits are proposed to improve signal-to-noise-plus-distortion ratio.The 200Ms/s 8bit ADC with 177mW total power consumption at 3.3V power supply is realized in standard digital 0.18μm 3.3V CMOS technology.展开更多
Improved waveguide designs for 9.0μm GaAs-based quantum cascade laser (QCL) structures are presented. Modal losses and confinement factors are calculated for TM modes with the transfer matrix method (TMM) and eff...Improved waveguide designs for 9.0μm GaAs-based quantum cascade laser (QCL) structures are presented. Modal losses and confinement factors are calculated for TM modes with the transfer matrix method (TMM) and effective index method (EIM). The thicknesses of the cladding layer and waveguide layer, the ridge-width, and the cavity length are all taken into account. Appropriate thicknesses of epilayers are given with lower threshold gain and more economical material growth time.展开更多
Objective: To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones.Methods: The data of 12 cases of infected nonunion and exposed bone following open fracture trea...Objective: To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones.Methods: The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients,whose age were between 19-52 years and averaged 28 years.There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition.Results: Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months afer operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence.Conclusion: The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.展开更多
An interrogation sensor system combining the "figure-of-eight" fiber loop mirror using a single directional 3×3 fiber optic coupler was proposed. One fiber loop mirror was formed by inserting a length of high b...An interrogation sensor system combining the "figure-of-eight" fiber loop mirror using a single directional 3×3 fiber optic coupler was proposed. One fiber loop mirror was formed by inserting a length of high birefringent optical fiber at the input ports of the 3×3 coupler. Splicing the output ports of the 3×3 coupler between them created the other fiber loop mirror. The introduction of this second loop gave rise to two polarization states of light with the same frequency but different optical phase. The mechanical torsion sensing head was located at the second loop and was exhibited an average modulus torsion sensitivity of 7.9×10^-4 degree/dB. The performance of the sensor was not affected by environmental temperature variations. Keywords: Torsion sensor, fiber loop mirror, interferometer展开更多
文摘A CMOS folding and interpolating analog-to-digital converter (ADC) for embedded application is described.The circuit is fully compatible with standard digital CMOS technology.A modified folding block implemented without resistor contributes to a small chip area.At the input stage,offset averaging reduces the input capacitance and the distributed track-and-hold circuits are proposed to improve signal-to-noise-plus-distortion ratio.The 200Ms/s 8bit ADC with 177mW total power consumption at 3.3V power supply is realized in standard digital 0.18μm 3.3V CMOS technology.
文摘Improved waveguide designs for 9.0μm GaAs-based quantum cascade laser (QCL) structures are presented. Modal losses and confinement factors are calculated for TM modes with the transfer matrix method (TMM) and effective index method (EIM). The thicknesses of the cladding layer and waveguide layer, the ridge-width, and the cavity length are all taken into account. Appropriate thicknesses of epilayers are given with lower threshold gain and more economical material growth time.
文摘Objective: To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones.Methods: The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients,whose age were between 19-52 years and averaged 28 years.There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition.Results: Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months afer operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence.Conclusion: The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.
文摘An interrogation sensor system combining the "figure-of-eight" fiber loop mirror using a single directional 3×3 fiber optic coupler was proposed. One fiber loop mirror was formed by inserting a length of high birefringent optical fiber at the input ports of the 3×3 coupler. Splicing the output ports of the 3×3 coupler between them created the other fiber loop mirror. The introduction of this second loop gave rise to two polarization states of light with the same frequency but different optical phase. The mechanical torsion sensing head was located at the second loop and was exhibited an average modulus torsion sensitivity of 7.9×10^-4 degree/dB. The performance of the sensor was not affected by environmental temperature variations. Keywords: Torsion sensor, fiber loop mirror, interferometer