The production cross-sections, intensity ratios, and radiative Auger intensity ratios of Co, Ni, Cu, and Zn elements in different complexes were measured. The chemical effects on the K shell fluorescence parameters an...The production cross-sections, intensity ratios, and radiative Auger intensity ratios of Co, Ni, Cu, and Zn elements in different complexes were measured. The chemical effects on the K shell fluorescence parameters and the radiative Auger intensity ratios of these elements were investigated and the changes in these parameters were interpreted according to the charge transfer process. The samples were excited by 59.5 keV γ-rays from a ^241Am annular radioactive source. K X-rays emitted by samples were counted by an Ultra-LEGe detector with a resolution of 150 eV at 5.9 keV.展开更多
Fiber Bragg grating under transverse force on a small grating section is studied by numerical simulation and experimentation. A numerical simulation based on the transfer matrix method is used to calculate the consequ...Fiber Bragg grating under transverse force on a small grating section is studied by numerical simulation and experimentation. A numerical simulation based on the transfer matrix method is used to calculate the consequent changes in reflected spectrum. The reflected spectra of the FBG subjected to the transverse force split into two main peaks, and the split point shifted linearly and periodically versus the applied force. The split point is shifted in the bandwidth with the period of 11N, and the sensitivity of the split point wavelength shift versus the applied force is 0.05 nm/N in one period. The experimental results show good agreement with the simulation analysis.展开更多
文摘The production cross-sections, intensity ratios, and radiative Auger intensity ratios of Co, Ni, Cu, and Zn elements in different complexes were measured. The chemical effects on the K shell fluorescence parameters and the radiative Auger intensity ratios of these elements were investigated and the changes in these parameters were interpreted according to the charge transfer process. The samples were excited by 59.5 keV γ-rays from a ^241Am annular radioactive source. K X-rays emitted by samples were counted by an Ultra-LEGe detector with a resolution of 150 eV at 5.9 keV.
基金This paper was supported by China National Science Foundation(60377002) .
文摘Fiber Bragg grating under transverse force on a small grating section is studied by numerical simulation and experimentation. A numerical simulation based on the transfer matrix method is used to calculate the consequent changes in reflected spectrum. The reflected spectra of the FBG subjected to the transverse force split into two main peaks, and the split point shifted linearly and periodically versus the applied force. The split point is shifted in the bandwidth with the period of 11N, and the sensitivity of the split point wavelength shift versus the applied force is 0.05 nm/N in one period. The experimental results show good agreement with the simulation analysis.