Novel 2×2 torsion-mirror optical switch arrays are fabricated by using the mixed micromachining based on the surface and bulk silicon microelectronics,then are investigated electromechanically in applied direct a...Novel 2×2 torsion-mirror optical switch arrays are fabricated by using the mixed micromachining based on the surface and bulk silicon microelectronics,then are investigated electromechanically in applied direct and alternating electric fields.When the thickness of the elastic torsion beams suspending the aluminum coated polysilicon micro-mirrors of the switches in the arrays is about 1μm,the electrostatic yielding voltages for driving the mirrors to achieve their ON-state are in the range of 270~290V,and the minimum holding voltages for mirrors ON-state are found as 55V or so.Theoretical analysis manifests that the yielding voltage is more sensitive to beam thickness than other design parameters do about the torsion-mirror switch structures.The lifetime can reach 10 8 times.The estimated shortest switching time of the switches at least lasts for less than 2ms.The force analysis on the two kinds of new fiber self-holding structures integrated monolithically in the chip of the optical switch arrays indicates that the structures can feature self-fixing and self-aligning of optical fibers.展开更多
The existence of a multi-path channel under the water greatly decreases the accuracy of the short baseline positioning system.In this paper,the application of a time reversal mirror to the short baseline positioning s...The existence of a multi-path channel under the water greatly decreases the accuracy of the short baseline positioning system.In this paper,the application of a time reversal mirror to the short baseline positioning system was investigated.The time reversal mirror technique allowed the acoustic signal to better focus in an unknown environment,which effectively reduced the expansion of multi-path acoustic signals as well as improved the signal focusing.The signal-to-noise ratio(SNR) of the time reversal operator greatly increased and could be obtained by ensonifying the water.The technique was less affected by the environment and therefore more applicable to a complex shallow water environment.Numerical simulations and pool experiments were used to demonstrate the efficiency of this technique.展开更多
In the wireless power transfer system for freely moving biomedical implants,the receiving unit was generally inefficient for the reason that its design parameters including the receiving coil's dimension and recei...In the wireless power transfer system for freely moving biomedical implants,the receiving unit was generally inefficient for the reason that its design parameters including the receiving coil's dimension and receiving circuits' topology were always determined by experiments.In order to build the relationship between these parameters and the total transfer efficiency,this paper developed a novel efficiency model based on the impedance model of the coil and the circuit model of the receiving circuits.According to the design constraints,the optimal design parameters in the worst case were derived.The results indicate that the combination of the two-layered receiving coil and half-bridge rectifier has more advantages in size,efficiency and safety,which is preferred in the receiving unit.Additionally,when the load resistance increases,the optimal turn number of the receiving coil basically keeps constant and the corresponding transmitting current and total efficiency decrease.For 100 Ω load,the transmitting current and total efficiency in the worst case were measured to be 5.30 A and 1.45% respectively,which are much better than the published results.In general,our work provides an efficient method to determine the design parameters of the wireless power transfer system for freely moving biomedical implants.展开更多
文摘Novel 2×2 torsion-mirror optical switch arrays are fabricated by using the mixed micromachining based on the surface and bulk silicon microelectronics,then are investigated electromechanically in applied direct and alternating electric fields.When the thickness of the elastic torsion beams suspending the aluminum coated polysilicon micro-mirrors of the switches in the arrays is about 1μm,the electrostatic yielding voltages for driving the mirrors to achieve their ON-state are in the range of 270~290V,and the minimum holding voltages for mirrors ON-state are found as 55V or so.Theoretical analysis manifests that the yielding voltage is more sensitive to beam thickness than other design parameters do about the torsion-mirror switch structures.The lifetime can reach 10 8 times.The estimated shortest switching time of the switches at least lasts for less than 2ms.The force analysis on the two kinds of new fiber self-holding structures integrated monolithically in the chip of the optical switch arrays indicates that the structures can feature self-fixing and self-aligning of optical fibers.
基金Supported by the National Defense Basic Foundation of China B2420710007
文摘The existence of a multi-path channel under the water greatly decreases the accuracy of the short baseline positioning system.In this paper,the application of a time reversal mirror to the short baseline positioning system was investigated.The time reversal mirror technique allowed the acoustic signal to better focus in an unknown environment,which effectively reduced the expansion of multi-path acoustic signals as well as improved the signal focusing.The signal-to-noise ratio(SNR) of the time reversal operator greatly increased and could be obtained by ensonifying the water.The technique was less affected by the environment and therefore more applicable to a complex shallow water environment.Numerical simulations and pool experiments were used to demonstrate the efficiency of this technique.
基金supported by the National Natural Science Foundation of China(Grant No.61473281)the National Sciences and Technology Support Project(Grant No.2015BAI01B13)State Key Laboratory of Robotics Self-plan Project(Grant No.2016-Z06)
文摘In the wireless power transfer system for freely moving biomedical implants,the receiving unit was generally inefficient for the reason that its design parameters including the receiving coil's dimension and receiving circuits' topology were always determined by experiments.In order to build the relationship between these parameters and the total transfer efficiency,this paper developed a novel efficiency model based on the impedance model of the coil and the circuit model of the receiving circuits.According to the design constraints,the optimal design parameters in the worst case were derived.The results indicate that the combination of the two-layered receiving coil and half-bridge rectifier has more advantages in size,efficiency and safety,which is preferred in the receiving unit.Additionally,when the load resistance increases,the optimal turn number of the receiving coil basically keeps constant and the corresponding transmitting current and total efficiency decrease.For 100 Ω load,the transmitting current and total efficiency in the worst case were measured to be 5.30 A and 1.45% respectively,which are much better than the published results.In general,our work provides an efficient method to determine the design parameters of the wireless power transfer system for freely moving biomedical implants.