The counter-rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures, has been proposed. In the unit, the front and the rear...The counter-rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures, has been proposed. In the unit, the front and the rear runners counter-drive the inner and the outer armatures of the generator, respectively. Besides, the flow direction at the rear runner outlet must coincide with the direction at the front runner inlet, because the angular momentum change through the rear runner must coincides with that through the front runner. In this paper, the tandem runners work at on-cam conditions in keeping the induced frequency constant, to provide the hydroelectric unit for the power grid system. The output and the hydraulic efficiency are affected by the adjusting angles of the front and the rear blades. Both optimum angles giving the maximum output or efficiency were presented at the various discharge/head circumstances, accompanying with the turbine performances.展开更多
It is difficult for renewable energy resources to provide constant power with excellent quality for the grid system. This serial research proposes a power stabilization system with a pumped storage to guarantee power ...It is difficult for renewable energy resources to provide constant power with excellent quality for the grid system. This serial research proposes a power stabilization system with a pumped storage to guarantee power quality and capacity, while the outputs from the energy resources are at unstable and/or fluctuating conditions. The power stabilization system with a counter-rotating type pump-turbine unit was prepared and operated at the pumping and the turbine modes. The unit composed of the tandem impellers/runners connected to the inner and the outer armatures of the unique motor/generator. The experiments have verified that this type pump-turbine unit is reasonably effective to stabilize momentarily/instantaneously the fluctuating power from the renewable energy resources.展开更多
With the growing energetic need present in the world, it is increasingly necessary for the researches and facilities to seek a better use of renewable natural resources. This paper is applied in the study of the perfo...With the growing energetic need present in the world, it is increasingly necessary for the researches and facilities to seek a better use of renewable natural resources. This paper is applied in the study of the performance of the aeration system of the Francis turbines present in Itaipu Hydroelectric Power Plant. When a Francis turbine operates off its optimal conditions, a vortex is formed inside the draft tube that, besides produces cavitation and pressure fluctuations, can pulse at frequencies with risk of resonance with hydraulic system, producing efforts and vibrations that may cause structural failures in the turbines, generators and civil parts of the power house. These damaging effects can be reduced using atmospheric aeration of the turbines. Because of this, the availability and effectively of the aeration system is fundamental to smooth the behavior of the turbines, helping preserve the health of the power plant. An analysis of the performance of the aeration system will be done using maintenance records and disturbances analysis reports (RAP), allowing verification of the operating conditions of the turbine and fatality of water inlet in air pipes. Through the improvements detected, it is possible to reduce machine stoppages by tripping, thus increasing the availability of the turbines.展开更多
This work concerns the study of HSs (Hybrid Systems) that are made up of the integration of M-HTFC (Medium and High Temperature Fuel Cell) and MGT (Micro-Gas-Turbine). Different typologies of hybrid systems are ...This work concerns the study of HSs (Hybrid Systems) that are made up of the integration of M-HTFC (Medium and High Temperature Fuel Cell) and MGT (Micro-Gas-Turbine). Different typologies of hybrid systems are taken into account, which differ from each other in their plant layouts. The plants are considered in cogenerative arrangement. The aim of this study is to carry out an energetic analysis of the HS considered to obtain an analytical expression to depict the system operating in cogenerative arrangement. An energetic comparison among the systems analyzed based on some indexes is effected, which allows an evaluation of the plants performances in cogenerative arrangement. An energetic analysis is carried out, which is based on a "black box" depiction of the plant in which the components and the mutual interactions are highlighted. The fuel cell component of the plant is not analyzed as a black box, but each element that constitutes it, is elaborated as a subsystem.展开更多
The flow rate measurements are the most difficult part of efficiency tests on prototype hydraulic turbines.Among the numerous flow rate measurement methods,the Winter Kennedy method is preferred for measuring turbine ...The flow rate measurements are the most difficult part of efficiency tests on prototype hydraulic turbines.Among the numerous flow rate measurement methods,the Winter Kennedy method is preferred for measuring turbine flow rates,since it is convenient,practical and economical.This paper describes efficiency tests on a large 300 MW Francis turbine,with the flow rate measured using the Winter Kennedy method and the Winter Kennedy flow rate coefficient calibrated using the Gibson method.The measured turbine efficiency curve is then compared with the curve provided by the manufacturer.The CFD calculations including the spiral case are then used to analyze the influence with the coefficient K and index n in the Winter Kennedy flow rate formula on the flow rate measurement.The uncertainty values of n and K are a key reason for the differences between the curves obtained from the efficiency test and the curves provided by the manufacturer.展开更多
This serial research proposes the hybrid power system combined the wind power unit with the counter-rotating type pump-turbine unit,to provide the constant output for the grid system,even at the suddenly fluctuating/t...This serial research proposes the hybrid power system combined the wind power unit with the counter-rotating type pump-turbine unit,to provide the constant output for the grid system,even at the suddenly fluctuating/turbulent wind.In this paper,the tandem impellers of the counter-rotating type pumping unit was operated at the turbine mode,and the performances and the flow conditions were investigated numerically and experimentally.The 3-D turbulent flows in the runners were simulated at the steady state condition by using the commercial CFD code of ANSYS-CFX ver.12 with the SST turbulence model.While providing the pump unit for the turbine mode,the maximum hydraulic efficiency is close to one of the counter-rotating type hydroelectric unit designed exclu-sively for the turbine mode.Besides,the runner/impeller of the unit works evidently so as to coincide the angularmomentum change through the front runners/impellers with that through the rear runners/impellers,namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.These results show that this type of unit is effective to work at not only the pumping but also the turbine modes.展开更多
文摘The counter-rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures, has been proposed. In the unit, the front and the rear runners counter-drive the inner and the outer armatures of the generator, respectively. Besides, the flow direction at the rear runner outlet must coincide with the direction at the front runner inlet, because the angular momentum change through the rear runner must coincides with that through the front runner. In this paper, the tandem runners work at on-cam conditions in keeping the induced frequency constant, to provide the hydroelectric unit for the power grid system. The output and the hydraulic efficiency are affected by the adjusting angles of the front and the rear blades. Both optimum angles giving the maximum output or efficiency were presented at the various discharge/head circumstances, accompanying with the turbine performances.
文摘It is difficult for renewable energy resources to provide constant power with excellent quality for the grid system. This serial research proposes a power stabilization system with a pumped storage to guarantee power quality and capacity, while the outputs from the energy resources are at unstable and/or fluctuating conditions. The power stabilization system with a counter-rotating type pump-turbine unit was prepared and operated at the pumping and the turbine modes. The unit composed of the tandem impellers/runners connected to the inner and the outer armatures of the unique motor/generator. The experiments have verified that this type pump-turbine unit is reasonably effective to stabilize momentarily/instantaneously the fluctuating power from the renewable energy resources.
文摘With the growing energetic need present in the world, it is increasingly necessary for the researches and facilities to seek a better use of renewable natural resources. This paper is applied in the study of the performance of the aeration system of the Francis turbines present in Itaipu Hydroelectric Power Plant. When a Francis turbine operates off its optimal conditions, a vortex is formed inside the draft tube that, besides produces cavitation and pressure fluctuations, can pulse at frequencies with risk of resonance with hydraulic system, producing efforts and vibrations that may cause structural failures in the turbines, generators and civil parts of the power house. These damaging effects can be reduced using atmospheric aeration of the turbines. Because of this, the availability and effectively of the aeration system is fundamental to smooth the behavior of the turbines, helping preserve the health of the power plant. An analysis of the performance of the aeration system will be done using maintenance records and disturbances analysis reports (RAP), allowing verification of the operating conditions of the turbine and fatality of water inlet in air pipes. Through the improvements detected, it is possible to reduce machine stoppages by tripping, thus increasing the availability of the turbines.
文摘This work concerns the study of HSs (Hybrid Systems) that are made up of the integration of M-HTFC (Medium and High Temperature Fuel Cell) and MGT (Micro-Gas-Turbine). Different typologies of hybrid systems are taken into account, which differ from each other in their plant layouts. The plants are considered in cogenerative arrangement. The aim of this study is to carry out an energetic analysis of the HS considered to obtain an analytical expression to depict the system operating in cogenerative arrangement. An energetic comparison among the systems analyzed based on some indexes is effected, which allows an evaluation of the plants performances in cogenerative arrangement. An energetic analysis is carried out, which is based on a "black box" depiction of the plant in which the components and the mutual interactions are highlighted. The fuel cell component of the plant is not analyzed as a black box, but each element that constitutes it, is elaborated as a subsystem.
基金supported by the National Natural Science Foundation of China (Grant No.50979044)State Key Laboratory of Hydroscience and Engineering of China (Grant No. 2009T3)
文摘The flow rate measurements are the most difficult part of efficiency tests on prototype hydraulic turbines.Among the numerous flow rate measurement methods,the Winter Kennedy method is preferred for measuring turbine flow rates,since it is convenient,practical and economical.This paper describes efficiency tests on a large 300 MW Francis turbine,with the flow rate measured using the Winter Kennedy method and the Winter Kennedy flow rate coefficient calibrated using the Gibson method.The measured turbine efficiency curve is then compared with the curve provided by the manufacturer.The CFD calculations including the spiral case are then used to analyze the influence with the coefficient K and index n in the Winter Kennedy flow rate formula on the flow rate measurement.The uncertainty values of n and K are a key reason for the differences between the curves obtained from the efficiency test and the curves provided by the manufacturer.
基金co-sponsored by Japan Society for the Promotion of Science KAKENHI23860035
文摘This serial research proposes the hybrid power system combined the wind power unit with the counter-rotating type pump-turbine unit,to provide the constant output for the grid system,even at the suddenly fluctuating/turbulent wind.In this paper,the tandem impellers of the counter-rotating type pumping unit was operated at the turbine mode,and the performances and the flow conditions were investigated numerically and experimentally.The 3-D turbulent flows in the runners were simulated at the steady state condition by using the commercial CFD code of ANSYS-CFX ver.12 with the SST turbulence model.While providing the pump unit for the turbine mode,the maximum hydraulic efficiency is close to one of the counter-rotating type hydroelectric unit designed exclu-sively for the turbine mode.Besides,the runner/impeller of the unit works evidently so as to coincide the angularmomentum change through the front runners/impellers with that through the rear runners/impellers,namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.These results show that this type of unit is effective to work at not only the pumping but also the turbine modes.