In this paper a new method has been proposed to decide optimal placement and best sizing of STATCOM (static synchronous compensator). The best place of STATCOM is found using the sensitivity analysis and optimum siz...In this paper a new method has been proposed to decide optimal placement and best sizing of STATCOM (static synchronous compensator). The best place of STATCOM is found using the sensitivity analysis and optimum sizing of STATCOM is managed using the genetic algorithm. The average model can account for the high-frequency effects and power electronic losses, and more accurately predict the active and reactive power outputs of the STATCOM. This paper employs the DIgSILENT simulator and DPL (DIgSILENT programming language) as a programming tool of the DIgSILENT to show the validity of the proposed method. The effectiveness of suggested approach has been tested on part of the distribution network of Iran, Khoramdarreh city in Zanjan province.展开更多
When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensat...When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensate reactive power following value U* according to the requirements of the Vietnamese power system dispath center, flit harmonic by passive filter... However, it still has some disadvantages of this substation that need to be overcome: use large number of main devices, generate harmonics by itself, cause a lot of active power losses. Thus, the authors have an idea to solve these problems by applying a bidirectional power converter with having difference circuit structure and PWM (pulse width modulation) controller with SVM (space vector modulation) pulse generated section, so compensative current which is created by inductance element can be reserved, adjust continuos and always has full sinusoidal form, not generating harmonic. The benefit of this new solution is to eliminate the three above fundamental disadvantages. This new model is built based on authors' research about BESS (battery energy storage system). The research results have been verified by simulations in Matlab/Simulink software.展开更多
文摘In this paper a new method has been proposed to decide optimal placement and best sizing of STATCOM (static synchronous compensator). The best place of STATCOM is found using the sensitivity analysis and optimum sizing of STATCOM is managed using the genetic algorithm. The average model can account for the high-frequency effects and power electronic losses, and more accurately predict the active and reactive power outputs of the STATCOM. This paper employs the DIgSILENT simulator and DPL (DIgSILENT programming language) as a programming tool of the DIgSILENT to show the validity of the proposed method. The effectiveness of suggested approach has been tested on part of the distribution network of Iran, Khoramdarreh city in Zanjan province.
文摘When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensate reactive power following value U* according to the requirements of the Vietnamese power system dispath center, flit harmonic by passive filter... However, it still has some disadvantages of this substation that need to be overcome: use large number of main devices, generate harmonics by itself, cause a lot of active power losses. Thus, the authors have an idea to solve these problems by applying a bidirectional power converter with having difference circuit structure and PWM (pulse width modulation) controller with SVM (space vector modulation) pulse generated section, so compensative current which is created by inductance element can be reserved, adjust continuos and always has full sinusoidal form, not generating harmonic. The benefit of this new solution is to eliminate the three above fundamental disadvantages. This new model is built based on authors' research about BESS (battery energy storage system). The research results have been verified by simulations in Matlab/Simulink software.