An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concret...An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concrete strengths of the columns were 30 MPa and 60 MPa.The primary variables considered were the concrete strength and the amount of transversereinforcement. Test results indicate that smaller hoop spacing provides higher column capacity andgreater strength enhancement in a confined concrete core of columns. For the same lateralconfinement, high strength concrete columns develop lower strength enhancement than normal strengthconcrete columns. Both the strength enhancement ratio (f'_(cc) /f'_(co)) and the column capacityratio (P_(test)/P_o) were observed to show linear increase variations with rho_s f_(yt)/f'_c incircular columns.展开更多
This paper investigated the compressive behavior of a novel glass fiber reinforced polymer(GFRP)-timber-reinforced concrete composite column(GTRC column),which consisted of reinforced concrete with an outer GFRP lamin...This paper investigated the compressive behavior of a novel glass fiber reinforced polymer(GFRP)-timber-reinforced concrete composite column(GTRC column),which consisted of reinforced concrete with an outer GFRP laminate and a paulownia timber core.The axial compression tests were performed on 13 specimens to validate the effects of various timber core diameters,slenderness ratios,and GFRP laminate layers/angles on the mechanical behaviors.Test results indicated that with the increase in the timber core diameter,the ductility and energy dissipation ability of the composite column increased by 52.6%and 21.6%,respectively,whereas the ultimate load-bearing capacity and initial stiffness showed a slight decrease.In addition,the GFRP laminate considerably improved the ultimate load-bearing capacity,stiffness,ductility and energy dissipation capability by 212.1%,26.6%,64.3%and 3820%,accordingly.Moreover,considering the influence of timber core diameter,an ultimate load-bearing capacity adjustment coefficient was proposed.Finally,a formula was established based on the force equilibrium and superposition for predicting the axial bearing capacity of the GTRC columns.展开更多
文摘An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concrete strengths of the columns were 30 MPa and 60 MPa.The primary variables considered were the concrete strength and the amount of transversereinforcement. Test results indicate that smaller hoop spacing provides higher column capacity andgreater strength enhancement in a confined concrete core of columns. For the same lateralconfinement, high strength concrete columns develop lower strength enhancement than normal strengthconcrete columns. Both the strength enhancement ratio (f'_(cc) /f'_(co)) and the column capacityratio (P_(test)/P_o) were observed to show linear increase variations with rho_s f_(yt)/f'_c incircular columns.
基金supported by the Program of the China Postdoctoral Science Foundation(Grant No.2021M690264 and 2021T140031)the Youth Talent Cultivation Program of Jiangsu University,and the State Key Laboratory of Special Functional Waterproof Materials(No.SKWL-2021KF10).
文摘This paper investigated the compressive behavior of a novel glass fiber reinforced polymer(GFRP)-timber-reinforced concrete composite column(GTRC column),which consisted of reinforced concrete with an outer GFRP laminate and a paulownia timber core.The axial compression tests were performed on 13 specimens to validate the effects of various timber core diameters,slenderness ratios,and GFRP laminate layers/angles on the mechanical behaviors.Test results indicated that with the increase in the timber core diameter,the ductility and energy dissipation ability of the composite column increased by 52.6%and 21.6%,respectively,whereas the ultimate load-bearing capacity and initial stiffness showed a slight decrease.In addition,the GFRP laminate considerably improved the ultimate load-bearing capacity,stiffness,ductility and energy dissipation capability by 212.1%,26.6%,64.3%and 3820%,accordingly.Moreover,considering the influence of timber core diameter,an ultimate load-bearing capacity adjustment coefficient was proposed.Finally,a formula was established based on the force equilibrium and superposition for predicting the axial bearing capacity of the GTRC columns.