In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and i...In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and improved monotonic spectrum emissivity model, the characteristics of radiation temperature measurement area restricted by the measurement coordinates were theoretically analyzed, through the investigations of the temperature and emissivity coordinate axes. Choosing the specific primary spectrum pyrometer as an example in applications, the theoretical area of radiation temperature measurement of this pyrometer was given and it was verified through blackbody experiments. The discussions of this paper will provide the necessary foundation for the theory research development of primary spectrum pyrometry and the realization of technical applications.展开更多
With the use ofa Geiger proportional counter with sensor tube of Russian and Chinese origin, a comparison was made in this work between measurements of environmental ionizing radiation with these detectors and a sodiu...With the use ofa Geiger proportional counter with sensor tube of Russian and Chinese origin, a comparison was made in this work between measurements of environmental ionizing radiation with these detectors and a sodium iodide scintillator activated with TI (Thallium NaI). Through measurements carried out in a room located inside a tower 25 meters high on the ITA (Technological Institute of Aeronautics) campus, it was possible to study the efficiency of the three instruments for the environmental measurement of ionizing radiations at that location. Between March 7th and June 2nd of 2017, in that region, nine intense and weak rains were observed with 12 cold fronts coming from southern Brazil. Radiation measurements and the local meteorology involved are analyzed in this work to verify possible correlations.展开更多
CdZnTe is an excellent material candidate for high efficiency,high-resolution room-temperature nuclear radiation detectors,and the CdZnTe detectors are being widely used in medicine,industry,safeguard and scientific X...CdZnTe is an excellent material candidate for high efficiency,high-resolution room-temperature nuclear radiation detectors,and the CdZnTe detectors are being widely used in medicine,industry,safeguard and scientific X-ray and γ-ray imaging and spectroscopic applications.In this work,three CdZnTe planar detectors with different grades,named CZT-1,CZT-2 and CZT-3,respectively,were fabricated.And the effects of mobility,lifetime and de-trapping time on the performance of CdZnTe planar detector,such as the energy resolution,charge collection efficiency and peak to valley ratio,were analyzed.The charge collection efficiency depends on the product of carrier mobility and lifetime,which has a great effect on the energy resolution of detector when the efficiency is less than 90%.The de-trapping time of carriers in deep levels should be responsible for the peak to valley ratio and "polarization".展开更多
基金This research was supported by the National Natural Science Foundation of China ( Grant No. 50606033);National High Technology Research and Development Program of China (Grant No. 2007AA04Z178 )
文摘In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and improved monotonic spectrum emissivity model, the characteristics of radiation temperature measurement area restricted by the measurement coordinates were theoretically analyzed, through the investigations of the temperature and emissivity coordinate axes. Choosing the specific primary spectrum pyrometer as an example in applications, the theoretical area of radiation temperature measurement of this pyrometer was given and it was verified through blackbody experiments. The discussions of this paper will provide the necessary foundation for the theory research development of primary spectrum pyrometry and the realization of technical applications.
文摘With the use ofa Geiger proportional counter with sensor tube of Russian and Chinese origin, a comparison was made in this work between measurements of environmental ionizing radiation with these detectors and a sodium iodide scintillator activated with TI (Thallium NaI). Through measurements carried out in a room located inside a tower 25 meters high on the ITA (Technological Institute of Aeronautics) campus, it was possible to study the efficiency of the three instruments for the environmental measurement of ionizing radiations at that location. Between March 7th and June 2nd of 2017, in that region, nine intense and weak rains were observed with 12 cold fronts coming from southern Brazil. Radiation measurements and the local meteorology involved are analyzed in this work to verify possible correlations.
基金supported by the National Instrumentation Program (GrantNo. 2011YQ040082)the National Natural Science Foundation of China(Grant Nos. 50902113,50902114)+3 种基金Program for New Century Excellent Talents in University (Grant No. NCET-10-0076)the National Basic Research Program of China ("973" Project) (Grant No. 2011CB610406)the"111" Project of China (Grant No. B08040)NPU Foundation for Fundamental Research (Grant No. JC20100228)
文摘CdZnTe is an excellent material candidate for high efficiency,high-resolution room-temperature nuclear radiation detectors,and the CdZnTe detectors are being widely used in medicine,industry,safeguard and scientific X-ray and γ-ray imaging and spectroscopic applications.In this work,three CdZnTe planar detectors with different grades,named CZT-1,CZT-2 and CZT-3,respectively,were fabricated.And the effects of mobility,lifetime and de-trapping time on the performance of CdZnTe planar detector,such as the energy resolution,charge collection efficiency and peak to valley ratio,were analyzed.The charge collection efficiency depends on the product of carrier mobility and lifetime,which has a great effect on the energy resolution of detector when the efficiency is less than 90%.The de-trapping time of carriers in deep levels should be responsible for the peak to valley ratio and "polarization".