This paper presents an efficient hierarchical occlusion test algorithm to support the global illumination solution such as Ray Tracing and Radiosity. This method, which is based on a cone volume intersection examinati...This paper presents an efficient hierarchical occlusion test algorithm to support the global illumination solution such as Ray Tracing and Radiosity. This method, which is based on a cone volume intersection examination, can rapidly remove the irrelevant parts in a scene and find the vertices which fall into the shadow area of a given object. It is an effective alternative to the conventional shadow feeler method.展开更多
The sipping test devices are used to identify the defective fuel. The defective fuel can be identified by detecting the occurrence of the fission products that are entrained by the medium rising around the fuel rods. ...The sipping test devices are used to identify the defective fuel. The defective fuel can be identified by detecting the occurrence of the fission products that are entrained by the medium rising around the fuel rods. This project is the setting of the two kinds of the three sipping test devices to inspect the tightness of the irradiated fuel assembly from two units NPP (nuclear power plant). The in-mast sipping shared by two units is used for qualitative tightness test of each fuel assembly during refueling operation above the reactor. The two poolside sipping is used for quantitatively confirming the diagnosis of the in-mast sipping and identifying the tightness of the fuel at the side of the fuel storage pools of each unit after refueling. The project was implemented by research, design manufacture and calibration of these three devices and completed successfully with serious quality assurance and quality control. The performance of these devices is well demonstrated.展开更多
Objective: To analyze the clinical outcomes of arthroscopic anterior cruciate ligament (ACL) reconstruction with irradiated bone-patellar tendon-bone (BPTB) allograft compared with non-irradiated allograft and au...Objective: To analyze the clinical outcomes of arthroscopic anterior cruciate ligament (ACL) reconstruction with irradiated bone-patellar tendon-bone (BPTB) allograft compared with non-irradiated allograft and autograft. Methods: All BPTB allografts were obtained from a single tissue bank and the irradiated allografts were sterilized with 2.5 mrad of irradiation prior to distribution. A total of 68 patients undergoing arthroscopic ACL reconstruction were prospectively randomized consecutively into one of the two groups (autograft and irradiated allograft groups). The same surgical technique was used in all operations done by the same senior surgeon. Before surgery and at the average of 31 months of follow-up (ranging from 24 to 47 months), patients were evaluated by the same observer according to objective and subjective clinical evaluations. Results: Of these patients, 65 (autograft 33, irradiated allograft 32) were available for full evaluation. When the irradiated allografl group was compared to the autograft group at the 31 -month follow-up by the Lachman test, the anterior drawer test (ADT), the pivot shift test, and KT-2000 arthrometer test, statistically significant differences were found. Most importantly, 87.8% of patients in the autograft group and just only 31.3% in the irradiated allograft group had a side-to-side difference of less than 3 mm according to KT-2000. The failure rate of the ACL reconstruction with irradiated allograft (34.4%) was higher than that with autograft (6.1%). The anterior and rotational stabilities decreased significantly in the irradiated allograft group. According to the overall International Knee Documentation Committee (1KDC), functional and subjective evaluations, and activity level testing, no statistically significant differences were found between the two groups. Besides, patients in the irradiated allograft group had a shorter operation time and a longer duration of postoperative fever. When the patients had a fever, the laboratory examinations of all patients were almost normal. Blood routine was normal, the values of erythrocyte sedimentation rate (ESR) were 5-16 mm/h and the contents of C reactive protein (CRP) were 3-10 mg/L. Conclusion: We conclude that the short term clinical outcomes of the ACL reconstruction with irradiated BPTB allograft were adversely affected. The less than satisfactory results led the senior authors to discontinue the use of irradiated BPTB allografl in ACL surgery and not to advocate using the gamma irradiation as a secondary sterilizing method.展开更多
文摘This paper presents an efficient hierarchical occlusion test algorithm to support the global illumination solution such as Ray Tracing and Radiosity. This method, which is based on a cone volume intersection examination, can rapidly remove the irrelevant parts in a scene and find the vertices which fall into the shadow area of a given object. It is an effective alternative to the conventional shadow feeler method.
文摘The sipping test devices are used to identify the defective fuel. The defective fuel can be identified by detecting the occurrence of the fission products that are entrained by the medium rising around the fuel rods. This project is the setting of the two kinds of the three sipping test devices to inspect the tightness of the irradiated fuel assembly from two units NPP (nuclear power plant). The in-mast sipping shared by two units is used for qualitative tightness test of each fuel assembly during refueling operation above the reactor. The two poolside sipping is used for quantitatively confirming the diagnosis of the in-mast sipping and identifying the tightness of the fuel at the side of the fuel storage pools of each unit after refueling. The project was implemented by research, design manufacture and calibration of these three devices and completed successfully with serious quality assurance and quality control. The performance of these devices is well demonstrated.
基金Project (No. 2004GG2202034) supported by the Natural Science Foundation of Shandong Province, China
文摘Objective: To analyze the clinical outcomes of arthroscopic anterior cruciate ligament (ACL) reconstruction with irradiated bone-patellar tendon-bone (BPTB) allograft compared with non-irradiated allograft and autograft. Methods: All BPTB allografts were obtained from a single tissue bank and the irradiated allografts were sterilized with 2.5 mrad of irradiation prior to distribution. A total of 68 patients undergoing arthroscopic ACL reconstruction were prospectively randomized consecutively into one of the two groups (autograft and irradiated allograft groups). The same surgical technique was used in all operations done by the same senior surgeon. Before surgery and at the average of 31 months of follow-up (ranging from 24 to 47 months), patients were evaluated by the same observer according to objective and subjective clinical evaluations. Results: Of these patients, 65 (autograft 33, irradiated allograft 32) were available for full evaluation. When the irradiated allografl group was compared to the autograft group at the 31 -month follow-up by the Lachman test, the anterior drawer test (ADT), the pivot shift test, and KT-2000 arthrometer test, statistically significant differences were found. Most importantly, 87.8% of patients in the autograft group and just only 31.3% in the irradiated allograft group had a side-to-side difference of less than 3 mm according to KT-2000. The failure rate of the ACL reconstruction with irradiated allograft (34.4%) was higher than that with autograft (6.1%). The anterior and rotational stabilities decreased significantly in the irradiated allograft group. According to the overall International Knee Documentation Committee (1KDC), functional and subjective evaluations, and activity level testing, no statistically significant differences were found between the two groups. Besides, patients in the irradiated allograft group had a shorter operation time and a longer duration of postoperative fever. When the patients had a fever, the laboratory examinations of all patients were almost normal. Blood routine was normal, the values of erythrocyte sedimentation rate (ESR) were 5-16 mm/h and the contents of C reactive protein (CRP) were 3-10 mg/L. Conclusion: We conclude that the short term clinical outcomes of the ACL reconstruction with irradiated BPTB allograft were adversely affected. The less than satisfactory results led the senior authors to discontinue the use of irradiated BPTB allografl in ACL surgery and not to advocate using the gamma irradiation as a secondary sterilizing method.