An 86-year-old male patient was admitted in our cardiology ward with signs of congestive biventricular heart failure. The patient presented with deteriorating dyspnea on mild exertion and at rest the last days, compat...An 86-year-old male patient was admitted in our cardiology ward with signs of congestive biventricular heart failure. The patient presented with deteriorating dyspnea on mild exertion and at rest the last days, compatible with class NYHA Ⅲ-Ⅳ heart failure, bilateral peripheral oedema, increased NT-proBNP (9198 pg/mL), mildly elevated Troponin (TnT 64 pg/mL), interstitial pulmonary oedema and bilateral pleural effusions in chest X ray.展开更多
The excessive moisture has an adverse effect on the building materials structure. Most standard construction materials are characterized by porous structure, resulting in the ability to absorb water in liquid and gase...The excessive moisture has an adverse effect on the building materials structure. Most standard construction materials are characterized by porous structure, resulting in the ability to absorb water in liquid and gaseous phases in the inner pores. Under certain conditions, water fills the pores within the structure of building material and then moves back to its surrounding. Many technical studies have shown that monitoring the moisture transport is mainly based on experimental methods. This work is based on models of transport of moisture in building physics, i.e., the description of the moisture behaviour of building materials based on physical laws models (KRISCHER, KIESSL). The aim of this work is to obtain the parameters of distribution of moisture for calculation capillary conductivity coefficient for practical using by means of non-destructive method. The authors have now developed all the software required to perform a boundary element analysis of problems in potential flow. The examples which the authors can analyse will, however, be restricted to homogenous domains.展开更多
文摘An 86-year-old male patient was admitted in our cardiology ward with signs of congestive biventricular heart failure. The patient presented with deteriorating dyspnea on mild exertion and at rest the last days, compatible with class NYHA Ⅲ-Ⅳ heart failure, bilateral peripheral oedema, increased NT-proBNP (9198 pg/mL), mildly elevated Troponin (TnT 64 pg/mL), interstitial pulmonary oedema and bilateral pleural effusions in chest X ray.
文摘The excessive moisture has an adverse effect on the building materials structure. Most standard construction materials are characterized by porous structure, resulting in the ability to absorb water in liquid and gaseous phases in the inner pores. Under certain conditions, water fills the pores within the structure of building material and then moves back to its surrounding. Many technical studies have shown that monitoring the moisture transport is mainly based on experimental methods. This work is based on models of transport of moisture in building physics, i.e., the description of the moisture behaviour of building materials based on physical laws models (KRISCHER, KIESSL). The aim of this work is to obtain the parameters of distribution of moisture for calculation capillary conductivity coefficient for practical using by means of non-destructive method. The authors have now developed all the software required to perform a boundary element analysis of problems in potential flow. The examples which the authors can analyse will, however, be restricted to homogenous domains.