A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filte...A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized.展开更多
A herringbone water-sediment separation structure(hereinafter referred to as "herringbone structure") has been shown to be effective in separating coarse inorganic debris; however, less is known regarding th...A herringbone water-sediment separation structure(hereinafter referred to as "herringbone structure") has been shown to be effective in separating coarse inorganic debris; however, less is known regarding the large wood(LW) filtration effect in this structure. This paper presents preliminary research on the wood filtration effect of the herringbone structure based on physical model tests.The results show that the herringbone structure exhibited effective performance in large wood size segregation, with a 100% component filtration rate for LW that diameter(D) larger than ribbed beam opening width(a). The total filtration rate also exceeded 80% when the Fraud number(Fr) is larger than 2.64 and increased with the increase of Fr. After exceeding Frmax, total filtration rate would be decreased due to overflow. Beside flow condition,structure parameters influence significantly on LW filtration rate. We attempt to explain the filtration process via particle contact trajectory and particle movement trajectory. The inclined angle of ribbed beam(γ) contributed the most variation to the filtration rate via influencing the coincidence with particle contact trajectory and particle movement trajectory. The high sensitivity coefficient of ribbed beam(θ) under relatively low Fr conditions implies remarkable influences on LW filtration effects by causing clogging problem. The ribbed beam opening width(a) together with LW diameter(D) influenced the size segregation performance.展开更多
A simple harmonic motion is proposed to make the membrane move in a simpleharmonic way so as to enhance the membrane filtration, and minimize the membrane fouling andconcentration polarization. The velocity distributi...A simple harmonic motion is proposed to make the membrane move in a simpleharmonic way so as to enhance the membrane filtration, and minimize the membrane fouling andconcentration polarization. The velocity distribution and pressure distribution are deduced from theNavier-Stokes equation on the basis of a laminar flow when the membrane rotates at the speed of Asin(αt). And then the shear stress, shear force, moment of force on the membrane surface and powerconsumed by viscous force are calculated. The velocity distribution demonstrates that the phase ofmembrane velocity does not synchronize with that of shear stress. The simple harmonic motion canresult in self-cleaning, optimize energy utilization, provide the velocity field with instability,and make the feed fluid fluctuation. It also results in higher shear stress on the membrane surfacethan the constant motion when they consume the same quantitative energy.展开更多
Ionic partition equilibrium in charged membrane immersed in solution of single electrolyte with monovalence or multi-valence is systematically investigated and several expressions are established for determination of ...Ionic partition equilibrium in charged membrane immersed in solution of single electrolyte with monovalence or multi-valence is systematically investigated and several expressions are established for determination of partition coefficients. On this basis, the effects of the ratio of membrane charge density to bulk electrolyte solution concentration, the charge sign and valence of electrolyte ions and the type of membrane on the partition equilibrium were analyzed and simulated within chosen parameters. It is revealed that ion partition is not related solely with the respective concentrations but also definitely with the concentration ratio of fixed group to bulk solution in addition to the charge sign and the valence. For a counterion, the partition coefficient increases with this ratio and the valence; while for a coion, the partition coefficient decreases with this ratio and the valence. The theoretical calculations were compared with the experimental data and a good agreement was observed.展开更多
Based on the analysis of high-speed video images, the detachment behavior of dust cake from the ceramic candle filter surface during pulse cleaning process is investigated. The influences of the dust cake loading,the ...Based on the analysis of high-speed video images, the detachment behavior of dust cake from the ceramic candle filter surface during pulse cleaning process is investigated. The influences of the dust cake loading,the reservoir pressure, and the filtration velocity on the cleaning effectiveness are analyzed. Experimental results show that there exists an optimum dust cake thickness for pulse-cleaning process. For thin dust cake, the patchy cleaning exists and the cleaning efficiency is low; if the dust cake is too thick, the pressure drop across the dust cake becomes higher and a higher reservoir pressure may be needed. At the same time there also exists an optimum reservoir pressure for a given filtration condition.展开更多
The Yangzi Petrochemical Company has successfully imple-mented the test commissioning of a 45 t/h pressure filter (base on dry feed material) installed in the PTA unit with its pressure filter technique commanding a l...The Yangzi Petrochemical Company has successfully imple-mented the test commissioning of a 45 t/h pressure filter (base on dry feed material) installed in the PTA unit with its pressure filter technique commanding a leading展开更多
Nanofiltration separation has become a popular technique for removing largeorganic molecules and inorganic substances from water. It is achieved by a combination of threemechanisms: electrostatic repulsion, sieving an...Nanofiltration separation has become a popular technique for removing largeorganic molecules and inorganic substances from water. It is achieved by a combination of threemechanisms: electrostatic repulsion, sieving and diffusion. In the present work, a model based onirreversible thermodynamics is extended and used to estimate rejection of inorganic salts andorganic substances. Binary systems are modeled, where the feed contains an ion that is much lesspermeable to the membrane as compared with the other ion. The two model parameters are estimated byfitting the model to the experimental data. Variation of these parameters with the composition ofthe feed is described by an empirical correlation. This work attempts to describe transport throughthe nanofiltration membranes by a simple model.展开更多
This paper presents an investigation of a new method of purifying cryogenic liquid using sintered metallic wire-mesh filter, which has the advantages of high purifying efficiency and preferred strength at absolutely l...This paper presents an investigation of a new method of purifying cryogenic liquid using sintered metallic wire-mesh filter, which has the advantages of high purifying efficiency and preferred strength at absolutely low temperature. Experiments are conducted to purify solid CO2 particles from liquid nitrogen. Temperature and pressure in the upstream and downstream of the filter, and the flow rate of carbon dioxide (CO2) gas and liquid nitrogen are measured, with the gas content of filtrate analyzed using a CO2 concentration detector. It is illustrated that after filtration, the purity of liquid nitrogen (volume fraction) is higher than 99.99%, which means that the volume fraction of CO2 is less than 0.01%. Effects of operation parameters on the performance of the filter, such as pressure drop Ap and filtration efficiency E are analyzed quantitatively. The present conclusions will provide a guideline to the optimumal design and operation of sintered metallic wire-mesh filter in cryogenic application.展开更多
文摘A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized.
基金funded by the National Science and Technology Support Program(2011BAK12B00)the International Cooperation Project of the Department of Science and Technology of Sichuan Province(Grant No.2009HH0005).
文摘A herringbone water-sediment separation structure(hereinafter referred to as "herringbone structure") has been shown to be effective in separating coarse inorganic debris; however, less is known regarding the large wood(LW) filtration effect in this structure. This paper presents preliminary research on the wood filtration effect of the herringbone structure based on physical model tests.The results show that the herringbone structure exhibited effective performance in large wood size segregation, with a 100% component filtration rate for LW that diameter(D) larger than ribbed beam opening width(a). The total filtration rate also exceeded 80% when the Fraud number(Fr) is larger than 2.64 and increased with the increase of Fr. After exceeding Frmax, total filtration rate would be decreased due to overflow. Beside flow condition,structure parameters influence significantly on LW filtration rate. We attempt to explain the filtration process via particle contact trajectory and particle movement trajectory. The inclined angle of ribbed beam(γ) contributed the most variation to the filtration rate via influencing the coincidence with particle contact trajectory and particle movement trajectory. The high sensitivity coefficient of ribbed beam(θ) under relatively low Fr conditions implies remarkable influences on LW filtration effects by causing clogging problem. The ribbed beam opening width(a) together with LW diameter(D) influenced the size segregation performance.
文摘A simple harmonic motion is proposed to make the membrane move in a simpleharmonic way so as to enhance the membrane filtration, and minimize the membrane fouling andconcentration polarization. The velocity distribution and pressure distribution are deduced from theNavier-Stokes equation on the basis of a laminar flow when the membrane rotates at the speed of Asin(αt). And then the shear stress, shear force, moment of force on the membrane surface and powerconsumed by viscous force are calculated. The velocity distribution demonstrates that the phase ofmembrane velocity does not synchronize with that of shear stress. The simple harmonic motion canresult in self-cleaning, optimize energy utilization, provide the velocity field with instability,and make the feed fluid fluctuation. It also results in higher shear stress on the membrane surfacethan the constant motion when they consume the same quantitative energy.
基金Supported by the National Natural Science Foundation of China (No. 29976040), the Natural Science Foundation of Anhui Province(No. 99045431) and the Foundation of Environments and Resources of USTC (2000).
文摘Ionic partition equilibrium in charged membrane immersed in solution of single electrolyte with monovalence or multi-valence is systematically investigated and several expressions are established for determination of partition coefficients. On this basis, the effects of the ratio of membrane charge density to bulk electrolyte solution concentration, the charge sign and valence of electrolyte ions and the type of membrane on the partition equilibrium were analyzed and simulated within chosen parameters. It is revealed that ion partition is not related solely with the respective concentrations but also definitely with the concentration ratio of fixed group to bulk solution in addition to the charge sign and the valence. For a counterion, the partition coefficient increases with this ratio and the valence; while for a coion, the partition coefficient decreases with this ratio and the valence. The theoretical calculations were compared with the experimental data and a good agreement was observed.
基金Supported by the National Natural Science Foundation of China (No. 50376042)Doctoral Program Foundation of Institute of Higher Education of China (20040425007).
文摘Based on the analysis of high-speed video images, the detachment behavior of dust cake from the ceramic candle filter surface during pulse cleaning process is investigated. The influences of the dust cake loading,the reservoir pressure, and the filtration velocity on the cleaning effectiveness are analyzed. Experimental results show that there exists an optimum dust cake thickness for pulse-cleaning process. For thin dust cake, the patchy cleaning exists and the cleaning efficiency is low; if the dust cake is too thick, the pressure drop across the dust cake becomes higher and a higher reservoir pressure may be needed. At the same time there also exists an optimum reservoir pressure for a given filtration condition.
文摘The Yangzi Petrochemical Company has successfully imple-mented the test commissioning of a 45 t/h pressure filter (base on dry feed material) installed in the PTA unit with its pressure filter technique commanding a leading
文摘Nanofiltration separation has become a popular technique for removing largeorganic molecules and inorganic substances from water. It is achieved by a combination of threemechanisms: electrostatic repulsion, sieving and diffusion. In the present work, a model based onirreversible thermodynamics is extended and used to estimate rejection of inorganic salts andorganic substances. Binary systems are modeled, where the feed contains an ion that is much lesspermeable to the membrane as compared with the other ion. The two model parameters are estimated byfitting the model to the experimental data. Variation of these parameters with the composition ofthe feed is described by an empirical correlation. This work attempts to describe transport throughthe nanofiltration membranes by a simple model.
基金the National Natural Science Foundation of China(No.50476022)the Ministries and Commissions of Science and Technology of Shanghai Government(No.03DZ 14014)
文摘This paper presents an investigation of a new method of purifying cryogenic liquid using sintered metallic wire-mesh filter, which has the advantages of high purifying efficiency and preferred strength at absolutely low temperature. Experiments are conducted to purify solid CO2 particles from liquid nitrogen. Temperature and pressure in the upstream and downstream of the filter, and the flow rate of carbon dioxide (CO2) gas and liquid nitrogen are measured, with the gas content of filtrate analyzed using a CO2 concentration detector. It is illustrated that after filtration, the purity of liquid nitrogen (volume fraction) is higher than 99.99%, which means that the volume fraction of CO2 is less than 0.01%. Effects of operation parameters on the performance of the filter, such as pressure drop Ap and filtration efficiency E are analyzed quantitatively. The present conclusions will provide a guideline to the optimumal design and operation of sintered metallic wire-mesh filter in cryogenic application.