During our research,It has been found that body acceleration has strong relationships with the human energy expenditure.This paper discusses the methods to assess physical activity and concludes that for accurate asse...During our research,It has been found that body acceleration has strong relationships with the human energy expenditure.This paper discusses the methods to assess physical activity and concludes that for accurate assessment of physical activity under free living conditions the recently introduced accelerometer looks most promising.We developed a new computerized machine to assess the body activity and energy expenditure.Test datas of the treadmill experiment,respiration experiment and 5-kilometer-running experiment have been archieved,we found that body acceration integrals with time has linear relations with body energy expenture.展开更多
Moisture and water transfer under the condition of heavy sweating are analyzed. Four different experiments are made to test moisture resistance, water-keep, wicking effect and drying ability of samples. Then gray anal...Moisture and water transfer under the condition of heavy sweating are analyzed. Four different experiments are made to test moisture resistance, water-keep, wicking effect and drying ability of samples. Then gray analysis method is introduced to evaluate the comprehensive comfort of these fabrics. Result shows chemical fiber with high moisture transfer performance has advantage in water transfer and diffusion, which is suitable for human under the condition of heavy sweating. Though natural fiber can absorb moisture well, it cannot transfer fluid sweat. Therefore natural fiber fabrics such as cotton, wool are unsuitable to make functional sportswear.展开更多
Background:Relatively few studies on the peripheral sweating mechanisms of trained tennis athletes have been conducted.The purpose of this study was to compare the sweating capacities of tennis athletes against untra...Background:Relatively few studies on the peripheral sweating mechanisms of trained tennis athletes have been conducted.The purpose of this study was to compare the sweating capacities of tennis athletes against untrained subjects(controls).Methods:Thirty-fi e healthy male volunteers participated including 15 untrained subjects and 20 trained tennis athletes(nationally ranked).Active heat generation was performed for 30 min(running at 60%VO2max) in a climate chamber(temperature,25.0°C ± 0.5°C;relative humidity,60% ± 3%,termed active heating).Sweating data(local sweat onset time,local sweat volume,activated sweat glands,sweat output per gland,whole body sweat loss volume) were measured by the capacitance hygrometer-ventilated capsule method and starch-iodide paper.Mean body temperature was calculated from tympanic and skin temperatures.Results:Local sweat onset time was shorter for tennis athletes(p〈0.001).Local sweat volume,activated sweat glands of the torso and limbs,sweat output per gland,and whole body sweat loss volume were significant y higher for tennis athletes than control subjects after active heating(p〈0.001).Tympanic and mean body temperatures were lower among tennis athletes than controls(p〈0.05).Conclusion:These results indicate that tennis athletes had increased regulatory capacity of their sweat gland function.展开更多
文摘During our research,It has been found that body acceleration has strong relationships with the human energy expenditure.This paper discusses the methods to assess physical activity and concludes that for accurate assessment of physical activity under free living conditions the recently introduced accelerometer looks most promising.We developed a new computerized machine to assess the body activity and energy expenditure.Test datas of the treadmill experiment,respiration experiment and 5-kilometer-running experiment have been archieved,we found that body acceration integrals with time has linear relations with body energy expenture.
基金Shanghai Municipal Education Commission, No03YQHB073
文摘Moisture and water transfer under the condition of heavy sweating are analyzed. Four different experiments are made to test moisture resistance, water-keep, wicking effect and drying ability of samples. Then gray analysis method is introduced to evaluate the comprehensive comfort of these fabrics. Result shows chemical fiber with high moisture transfer performance has advantage in water transfer and diffusion, which is suitable for human under the condition of heavy sweating. Though natural fiber can absorb moisture well, it cannot transfer fluid sweat. Therefore natural fiber fabrics such as cotton, wool are unsuitable to make functional sportswear.
基金supported by the Soonchunhyang University Research Fund
文摘Background:Relatively few studies on the peripheral sweating mechanisms of trained tennis athletes have been conducted.The purpose of this study was to compare the sweating capacities of tennis athletes against untrained subjects(controls).Methods:Thirty-fi e healthy male volunteers participated including 15 untrained subjects and 20 trained tennis athletes(nationally ranked).Active heat generation was performed for 30 min(running at 60%VO2max) in a climate chamber(temperature,25.0°C ± 0.5°C;relative humidity,60% ± 3%,termed active heating).Sweating data(local sweat onset time,local sweat volume,activated sweat glands,sweat output per gland,whole body sweat loss volume) were measured by the capacitance hygrometer-ventilated capsule method and starch-iodide paper.Mean body temperature was calculated from tympanic and skin temperatures.Results:Local sweat onset time was shorter for tennis athletes(p〈0.001).Local sweat volume,activated sweat glands of the torso and limbs,sweat output per gland,and whole body sweat loss volume were significant y higher for tennis athletes than control subjects after active heating(p〈0.001).Tympanic and mean body temperatures were lower among tennis athletes than controls(p〈0.05).Conclusion:These results indicate that tennis athletes had increased regulatory capacity of their sweat gland function.