For describing the positioning process of High Intensity Focused Ultrasound (HIFU) Surgery Platform in the application in tumor treatment, a simplified representation of the shape and location of the positioning targe...For describing the positioning process of High Intensity Focused Ultrasound (HIFU) Surgery Platform in the application in tumor treatment, a simplified representation of the shape and location of the positioning target tumor in the workspace of the platform by the Positioning Volume Ellipsoid is designed; and the Nearest Neighbor Search method is used to find the closest center point of the simplified ellipsoid tumor model in a selected patient body surface point set determined by the motion parameter of the platform. By the query result the goal positioning path configuration and an intermediate positioning path configuration for the positioning motion are determined for the positioning motion planning. Three new criterions using distance change between Positioning Volume Ellipsoid and the Ultrasound Focus Ellipsoid are proposed to evaluate the result of the whole positioning procedure.展开更多
This paper studies the asymptotic behaviour of steady supersonic flow past a piecewise smooth corner or bend. Under the hypothese that both vertex angle and the total variation of tangent along the boundary are small,...This paper studies the asymptotic behaviour of steady supersonic flow past a piecewise smooth corner or bend. Under the hypothese that both vertex angle and the total variation of tangent along the boundary are small, it is shown that the solution can be obtained by a modified Glimm scheme, and that the asymptotic behaviour of the solution is determined by the velocity of incoming flow and the limit of the tangent of the boundary at infinity.展开更多
Scanning near-field acoustic microscope (SNAM) combines the ultrasonic detection technology with scanning near-field microscopy. The main characteristic of such microscope is that the acoustic wave is produced or de...Scanning near-field acoustic microscope (SNAM) combines the ultrasonic detection technology with scanning near-field microscopy. The main characteristic of such microscope is that the acoustic wave is produced or detected in near-field area whether ultrasonic transducer acts as generator or detector. The resolution of SNAM can reach to nanometer scale. First, two typical SNAMs, scanning electron acoustic Inicroscope and scanning probe acoustic microscope, will be introduced in this paper. The working principle of our homemade SNAM based on a commercial scanning probe microscope will be reported, together with some recent results from this homemade SNAM.展开更多
Focused ultrasound(FUS)-induced blood–brain barrier(BBB) opening is crucial for enhancing glioblastoma(GBM) therapies. However, an in vivo imaging approach with a high spatial–temporal resolution to monitor the BBB ...Focused ultrasound(FUS)-induced blood–brain barrier(BBB) opening is crucial for enhancing glioblastoma(GBM) therapies. However, an in vivo imaging approach with a high spatial–temporal resolution to monitor the BBB opening process in situ and synchronously is still lacking. Herein, we report the use of indocyanine green(ICG)-dopped microbubbles(MBs-ICG) for visualizing the FUS-induced BBB opening and enhancing the photothermal therapy(PTT) against GBM. The MBs-ICG show bright fluorescence in the second near-infrared window(NIR-II), ultrasound contrast, and ultrasound-induced size transformation properties. By virtue of complementary contrast properties, MBs-ICG can be successfully applied for cerebral vascular imaging with NIR-II fluorescence resolution of ~168.9 lm and ultrasound penetration depth of ~7 mm. We further demonstrate that MBs-ICG can be combined with FUS for in situ and synchronous visualization of the BBB opening with a NIR-II fluorescence signal-tobackground ratio of 6.2 ± 1.2. Finally, our data show that the MBs-ICG transform into lipid-ICG nanoparticles under FUS irradiation, which then rapidly penetrate the tumor tissues within 10 min and enhance PTT in orthotopic GBM-bearing mice. The multifunctional MBs-ICG approach provides a novel paradigm for monitoring BBB opening and enhancing GBM therapy.展开更多
文摘For describing the positioning process of High Intensity Focused Ultrasound (HIFU) Surgery Platform in the application in tumor treatment, a simplified representation of the shape and location of the positioning target tumor in the workspace of the platform by the Positioning Volume Ellipsoid is designed; and the Nearest Neighbor Search method is used to find the closest center point of the simplified ellipsoid tumor model in a selected patient body surface point set determined by the motion parameter of the platform. By the query result the goal positioning path configuration and an intermediate positioning path configuration for the positioning motion are determined for the positioning motion planning. Three new criterions using distance change between Positioning Volume Ellipsoid and the Ultrasound Focus Ellipsoid are proposed to evaluate the result of the whole positioning procedure.
基金Project supported by the National Natural Science Foundation of China (No.19701009)the Ministry of Education of China.
文摘This paper studies the asymptotic behaviour of steady supersonic flow past a piecewise smooth corner or bend. Under the hypothese that both vertex angle and the total variation of tangent along the boundary are small, it is shown that the solution can be obtained by a modified Glimm scheme, and that the asymptotic behaviour of the solution is determined by the velocity of incoming flow and the limit of the tangent of the boundary at infinity.
基金supported by the National Natural Science Foundation of China (Grant Nos.50971011 and 10874006)Beijing Natural Science Foundation (Grant No.1102025)Research Fund for the Doctoral Program of Higher Education of China (Grant No.20091102110038)
文摘Scanning near-field acoustic microscope (SNAM) combines the ultrasonic detection technology with scanning near-field microscopy. The main characteristic of such microscope is that the acoustic wave is produced or detected in near-field area whether ultrasonic transducer acts as generator or detector. The resolution of SNAM can reach to nanometer scale. First, two typical SNAMs, scanning electron acoustic Inicroscope and scanning probe acoustic microscope, will be introduced in this paper. The working principle of our homemade SNAM based on a commercial scanning probe microscope will be reported, together with some recent results from this homemade SNAM.
基金supported by the National Natural Science Foundation of China (92159304, 82171958, 81901812, 81971638, 91859117, 82027803, and 81927807)CAS Key Laboratory of Health Informatics (2011DP173015)+4 种基金the Science and Technology Key Project of Shenzhen(JCYJ20190812163614809, JCYJ20200109114612308, JCYJ2021032 4120011030, JCYJ20190809105207439, JCYJ20220531091408019, and JCYJ20200109114825064)Guangdong Basic and Applied Basic Research Fund (2020A1515110011, 2020A1515010395, and 2022A1515010384)Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province (2020B1212060051)the Key Technology and Equipment R&D Program of Major Science and Technology Infrastructure of Shenzhen (202100102, 202100104)Discipline Construction Project of Guangdong Medical University (4SG21017G)
文摘Focused ultrasound(FUS)-induced blood–brain barrier(BBB) opening is crucial for enhancing glioblastoma(GBM) therapies. However, an in vivo imaging approach with a high spatial–temporal resolution to monitor the BBB opening process in situ and synchronously is still lacking. Herein, we report the use of indocyanine green(ICG)-dopped microbubbles(MBs-ICG) for visualizing the FUS-induced BBB opening and enhancing the photothermal therapy(PTT) against GBM. The MBs-ICG show bright fluorescence in the second near-infrared window(NIR-II), ultrasound contrast, and ultrasound-induced size transformation properties. By virtue of complementary contrast properties, MBs-ICG can be successfully applied for cerebral vascular imaging with NIR-II fluorescence resolution of ~168.9 lm and ultrasound penetration depth of ~7 mm. We further demonstrate that MBs-ICG can be combined with FUS for in situ and synchronous visualization of the BBB opening with a NIR-II fluorescence signal-tobackground ratio of 6.2 ± 1.2. Finally, our data show that the MBs-ICG transform into lipid-ICG nanoparticles under FUS irradiation, which then rapidly penetrate the tumor tissues within 10 min and enhance PTT in orthotopic GBM-bearing mice. The multifunctional MBs-ICG approach provides a novel paradigm for monitoring BBB opening and enhancing GBM therapy.