Soil quality monitoring is important in precision agriculture.This study aimed to examine the possibility of assessing the soil parameters in apple-growing regions using spectroscopic methods.A total of 111 soil sampl...Soil quality monitoring is important in precision agriculture.This study aimed to examine the possibility of assessing the soil parameters in apple-growing regions using spectroscopic methods.A total of 111 soil samples were collected from 11 typical sites of apple orchards,and the croplands surrounding them.Near-infrared(NIR) and mid-infrared(MIR) spectra,combined with partial least square regression,were used to predict the soil parameters,including organic matter(OM) content,pH,and the contents of As,Cu,Zn,Pb,and Cr.Organic matter and pH were closely correlated with As and the heavy metals.The NIR model showed a high prediction accuracy for the determination of OM,pH,and As,with correlation coefficients(r) of 0.89,0.89,and 0.90,respectively.The predictions of these three parameters by MIR showed reduced accuracy,with r values of 0.77,0.84,and 0.92,respectively.The heavy metals could also be measured by spectroscopy due to their correlation with organic matter.Both NIR and MIR had high correlation coefficients for the determination of Cu,Zn,and Cr,with standard errors of prediction of 2.95,10.48,and 9.49 mg kg-1 for NIR and 3.69,5.84,and 6.94 mg kg-1 for MIR,respectively.Pb content behaved differently from the other parameters.Both NIR and MIR underestimated Pb content,with r values of 0.67 and 0.56 and standard errors of prediction of 3.46 and 2.99,respectively.Cu and Zn had a higher correlation with OM and pH and were better predicted than Pb and Cr.Thus,NIR spectra could accurately predict several soil parameters,metallic and nonmetallic,simultaneously,and were more feasible than MIR in analyzing soil parameters in the study area.展开更多
MS96A type spectrum analyzer was applied to determine the spectral characteristic of near infrared radiated by moxa stick moxi-bustion, ginger-partitioned moxibustion, garlicpartitioned moxibustion and Aconium Carmich...MS96A type spectrum analyzer was applied to determine the spectral characteristic of near infrared radiated by moxa stick moxi-bustion, ginger-partitioned moxibustion, garlicpartitioned moxibustion and Aconium Carmichaeli-p ar titioned moxibustion. The spectrum of moxa stick moxibustion was relatively discrete and several wave crests are appeared. But in the spectrum of ginger-partitioned moxibustion, garlic-partitioned moxibustion or Aconium Carmichaeli partitioned moxibustion, a specific and relatively steady wave crest formed respectively. It was concluded different indirect moxibustion could bring respective spectrum of near infrared and have the relevant physiologic and biochemical effects.展开更多
基金Supported by the Major Science and Technology Program for Water Pollution Control and Treatment in China(No.2008ZX07425-001)
文摘Soil quality monitoring is important in precision agriculture.This study aimed to examine the possibility of assessing the soil parameters in apple-growing regions using spectroscopic methods.A total of 111 soil samples were collected from 11 typical sites of apple orchards,and the croplands surrounding them.Near-infrared(NIR) and mid-infrared(MIR) spectra,combined with partial least square regression,were used to predict the soil parameters,including organic matter(OM) content,pH,and the contents of As,Cu,Zn,Pb,and Cr.Organic matter and pH were closely correlated with As and the heavy metals.The NIR model showed a high prediction accuracy for the determination of OM,pH,and As,with correlation coefficients(r) of 0.89,0.89,and 0.90,respectively.The predictions of these three parameters by MIR showed reduced accuracy,with r values of 0.77,0.84,and 0.92,respectively.The heavy metals could also be measured by spectroscopy due to their correlation with organic matter.Both NIR and MIR had high correlation coefficients for the determination of Cu,Zn,and Cr,with standard errors of prediction of 2.95,10.48,and 9.49 mg kg-1 for NIR and 3.69,5.84,and 6.94 mg kg-1 for MIR,respectively.Pb content behaved differently from the other parameters.Both NIR and MIR underestimated Pb content,with r values of 0.67 and 0.56 and standard errors of prediction of 3.46 and 2.99,respectively.Cu and Zn had a higher correlation with OM and pH and were better predicted than Pb and Cr.Thus,NIR spectra could accurately predict several soil parameters,metallic and nonmetallic,simultaneously,and were more feasible than MIR in analyzing soil parameters in the study area.
文摘MS96A type spectrum analyzer was applied to determine the spectral characteristic of near infrared radiated by moxa stick moxi-bustion, ginger-partitioned moxibustion, garlicpartitioned moxibustion and Aconium Carmichaeli-p ar titioned moxibustion. The spectrum of moxa stick moxibustion was relatively discrete and several wave crests are appeared. But in the spectrum of ginger-partitioned moxibustion, garlic-partitioned moxibustion or Aconium Carmichaeli partitioned moxibustion, a specific and relatively steady wave crest formed respectively. It was concluded different indirect moxibustion could bring respective spectrum of near infrared and have the relevant physiologic and biochemical effects.